§ 761.253 - Chemical analysis.  


Latest version.
  • § 761.253 Chemical analysis.

    (a) Extract PCBs Select applicable method(s) from the following list to extract PCBs and determine the PCB concentration from the standard wipe sample collection medium and clean-up the extracted PCBs in accordance with either Method 3500B/3540C or Method 3500B/3550B from EPA's SW-846, Test Methods for Evaluating Solid Waste, or a method validated under subpart Q of this part. Use Method 8082 from SW-846, or a method validated under subpart Q of this part, to analyze these extracts for PCBs.

    (

    : SW–846 Method 3540C, Method 3550C, Method 3541, Method 3545A, Method 3546, or Method 8082A (all standards incorporated by reference in § 761.19). Modifications to the methods listed in this paragraph or alternative methods not listed may be used if validated under Subpart Q of this part or authorized in a § 761.61(c) approval.

    (b) Report all PCB sample concentrations in µg/100 cm2 (16 square inches) of surface sampled. If sampling an area smaller than 100 cm2, report converted sample concentrations in accordance with § 761.243(b).

    [63 FR 35462, June 29, 1998, as amended at 88 FR 59695, Aug. 29, 2023]