§ 86.1238-90 - Hot soak test.  


Latest version.
  • The one-hour hot-soak evaporative emission test shall be conducted immediately following one cycle of the dynamometer driving schedule.

    (a) Prior to the completion of the dynamometer cycle, the evaporative emission enclosure shall be purged for several minutes.

    (b) The FID hydrocarbon analyzer shall be zeroed and spanned immediately prior to the test.

    (c) Fresh impingers shall be installed in the methanol sample collection system immediately prior to the start of the test, if applicable.

    (d) If not already on, the evaporative enclosure mixing fan(s) shall be turned on at this time.

    (e) Upon completion of the dynamometer run the exhaust tube shall be disconnected from the vehicle tailpipe(s), the cooling fan(s) shall be moved, and the vehicle shall be disconnected from the dynamometer and driven at minimum throttle to the vehicle entrance of the enclosure.

    (f) The vehicle's engine must be stopped before any part of the vehicle enters the enclosure. The vehicle may be pushed or coasted into the enclosure.

    (g) The test vehicle windows and any storage compartments shall be opened, if not already open.

    (h) The temperature recording system shall be started and the time of engine shut off shall be noted on the evaporative emissions hydrocarbon data recording system.

    (i) The enclosure doors shall be closed and sealed within two minutes of engine shutdown and within seven minutes after the end of the exhaust emission test. The steps after the end of the driving cycle should be done as quickly as possible to minimize the time needed to start the hot soak test.

    (j) The 60±0.5 minute hot soak begins when the enclosure doors are sealed. The enclosure atmosphere shall be analyzed and recorded. This is the initial (time = 0 minutes) hydrocarbon concentration, CHCi, for use in calculating evaporative losses (see § 86.1243). The “zero” time methanol sample shall be collected starting at the same time as the hydrocarbon analysis is started. Sampling shall continue for four minutes.

    (k) The test vehicle shall be permitted to soak for a period of one hour in the enclosure.

    (l) The FID hydrocarbon analyzer shall be zeroed and spanned immediately prior to the end of the test.

    (m) Fresh impingers shall be installed in the methanol collection system immediately prior to the end of the test, if applicable.

    (n) At the end of the 60±0.5 minute test period, the enclosure atmosphere shall again be analyzed (as described in § 86.1238-90(j) and the time recorded. This is the final (time = 60 minutes) hydrocarbon concentration, CHCf and the final methanol level for use in calculating evaporative losses (see § 86.1243). This operation completes the evaporative emission measurement procedure.

    (o) Alternate method for methanol sampling. Since sample times of longer than four minutes may be necessary in order to collect an adequate and representative sample of methanol at the end of a test (when SHED concentrations are usually increasing rapidly), it may be necessary to rapidly collect the methanol sample in a bag and then bubble the bag sample through the impingers at the specified flow rate. The time elapsed between collection of the bag sample and flowing through the impingers should be minimized in order to prevent any losses. This alternative must be adopted if the four minute sample period is inadequate to collect a sample of sufficient concentration to allow accurate GC analysis.