Code of Federal Regulations (Last Updated: July 5, 2024) |
![]() |
Title 40 - Protection of Environment |
![]() |
Chapter I - Environmental Protection Agency |
![]() |
SubChapter C - Air Programs |
![]() |
Part 90 - Control of Emissions from Nonroad Spark-Ignition Engines at or Below 19 Kilowatts |
![]() |
Subpart D - Emission Test Equipment Provisions |
§ 90.304 - Test equipment overview.
-
§ 90.304 Test equipment overview.
(a) All engines subject to this subpart are tested for exhaust emissions. Engines are operated on dynamometers meeting the specification given in § 90.305.
(b) The exhaust is tested for gaseous emissions using a raw gas sampling system as described in § 90.414 or a constant volume sampling (CVS) system as described in § 90.421. Both systems require analyzers (see paragraph (c) of this section) specific to the pollutant being measured.
(c) Analyzers used are a non-dispersive infrared (NDIR) absorption type for carbon monoxide and carbon dioxide analysis; paramagnetic (PMD), zirconia (ZRDO), or electrochemical type (ECS) for oxygen analysis; a flame ionization (FID) or heated flame ionization (HFID) type for hydrocarbon analysis; and a chemiluminescent detector (CLD) or heated chemiluminescent detector (HCLD) for oxides of nitrogen analysis.