§ 84.122 - Breathing resistance test; minimum requirements.  


Latest version.
  • § 84.122 Breathing resistance test; minimum requirements.

    (a) Resistance to airflow will be measured in the facepiece or mouthpiece of a gas mask mounted on a breathing machine both before and after each test conducted in accordance with §§ 84.124, 84.125, and 84.126, with air flowing at a continuous rate of 85 liters per minute.

    (b) The maximum allowable resistance requirements for gas masks are as follows:

    Maximum Resistance

    [mm. water-column height]

    Type of gas mask Inhalation Exhalation
    Initial Final1
    Front-mounted or back-mounted (without particulate filter) 60 75 20
    Front-mounted or back-mounted (with approved particulate filter) 70 85 20
    Chin-style (without particulate filter) 40 55 20
    Chin-style (with approved particulate filter) 65 80 20
    Escape (without particulate filter) 60 75 20
    Escape (with approved particulate filter) 70 85 20