§ 154.1010 - Electrical equipment in gas-dangerous space or zone.  


Latest version.
  • § 154.1010 Electrical equipment in gas-dangerous space or zone.

    (a) Except as allowed in this section, electrical equipment must not be installed in a gas-dangerous space or zone.

    (b) Intrinsically safe electrical equipment and wiring may be in a gas-dangerous space or zone.

    (c) A submerged cargo pump motor may be in a cargo tank if:

    (1) Low liquid level, motor current, or pump discharge pressure automatically shuts down power to the pump motor if the pump loses suction;

    (2) There is an audible and visual alarm at the cargo control station that actuates if the motor shuts down under the requirements of paragraph (c)(1) of this section; and

    (3) There is a lockable circuit breaker or lockable switch that disconnects the power to the motor.

    (d) A supply cable for a submerged cargo pump motor may be in a hold space.

    (e) A hold space that has a tank that is not required to have a secondary barrier under § 154.459 may only have:

    (1) Through runs of cable;

    (2) Explosion-proof lighting fixtures;

    (3) Depth sounding devices in gas-tight enclosures;

    (4) Log devices in gas-tight enclosures; and

    (5) Impressed current cathodic protection system electrodes in gas-tight enclosures.

    (f) A space that is separated by a gastight steel boundary from a hold space that has a cargo tank that must have a secondary barrier, under the requirements of § 154.459, may only have:

    (1) Through runs of cable;

    (2) Explosion-proof lighting fixtures;

    (3) Depth sounding devices in gastight enclosures;

    (4) Log devices in gastight enclosures;

    (5) Impressed current cathodic protection system electrodes in gastight enclosures;

    (6) Explosion-proof motors that operate cargo system valves or ballast system valves; and

    (7) Explosion-proof bells for general alarm systems.

    (g) A cargo handling room may only have:

    (1) Explosion-proof lighting fixtures; and

    (2) Explosion-proof bells for general alarm systems.

    (h) A space for cargo hose storage may only have:

    (1) Explosion-proof lighting fixtures; and

    (2) Through runs of cable.

    (i) A space that has cargo piping may only have:

    (1) Explosion-proof lighting fixtures; and

    (2) Through runs of cable.

    (j) A gas-dangerous zone on the weather deck may only have:

    (1) Explosion-proof equipment that is for the operation of the vessel; and

    (2) Through runs of cable.

    (k) A space, except those under paragraphs (e) through (j) of this section, that has a direct opening to a gas-dangerous space or zone may only have the electrical equipment allowed in the gas-dangerous space or zone.