§ 64.11 - Design of MPTs.  


Latest version.
  • § 64.11 Design of MPTs.

    An MPT must be designed -

    (a) In accordance with the ASME Code and this subpart;

    (b) With a maximum gross weight of 55,000 pounds;

    (c) To hold a liquid cargo that has a vapor pressure of 43 pounds per square inch absolute (psia) or less at a temperature of 122 °F;

    (d) With a minimum service temperature of 0 °F or higher;

    (e) With a maximum allowable working pressure of not less than 20 pounds per square inch gauge (psig) but not more than 48 psig; and

    (f) To withstand dynamic loading conditions applied simultaneously.

    [CGD 84-043, 55 FR 37410, Sept. 11, 1990; 55 FR 40755, Oct. 4, 1990]