§ 192.740 - Pressure regulating, limiting, and overpressure protection - Individual service lines directly connected to regulated gathering or transmission pipelines.  


Latest version.
  • § 192.740 Pressure regulating, limiting, and overpressure protection - Individual service lines directly connected to production, regulated gathering , or transmission pipelines.

    (a) This section applies, except as provided in paragraph (c) of this section, to any service line directly connected to a production, gathering, or transmission pipeline or regulated gathering pipeline as determined in § 192.8 that is not operated as part of a distribution system.

    (b) Each pressure regulating or limiting device, relief device (except rupture discs), automatic shutoff device, and associated equipment must be inspected and tested at least once every 3 calendar years, not exceeding 39 months, to determine that it is:

    (1) In good mechanical condition;

    (2) Adequate from the standpoint of capacity and reliability of operation for the service in which it is employed;

    (3) Set to control or relieve at the correct pressure consistent with the pressure limits of § 192.197; and to limit the pressure on the inlet of the service regulator to 60 psi (414 kPa) gauge or less in case the upstream regulator fails to function properly; and

    (4) Properly installed and protected from dirt, liquids, or other conditions that might prevent proper operation.

    (c) This section does not apply to equipment installed on:

    (1) A service

    lines

    line that only

    serve

    serves engines that power irrigation pumps;

    (2) A service line included in a distribution integrity management plan meeting the requirements of subpart P of this part; or

    (3) A service line directly connected to either a production or gathering pipeline other than a regulated gathering line as determined in § 192.8 of this part.

    [Amdt. 192-123, 82 FR 7998, Jan. 23, 2017, as amended at 86 FR 2241, Jan. 11, 2021]