Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 49 - Transportation |
Subtitle B - Other Regulations Relating to Transportation |
Chapter I - Pipeline and Hazardous Materials Safety Administration, Department of Transportation |
SubChapter D - Pipeline Safety |
Part 195 - Transportation of Hazardous Liquids by Pipeline |
Subpart H - Corrosion Control |
§ 195.587 - What methods are available to determine the strength of corroded pipe?
Latest version.
-
§ 195.587 What methods are available to determine the strength of corroded pipe?
Under § 195.585, you may use the procedure in ASME/ANSI B31G (incorporated by reference, see § 195.3) or in PRCI PR-3-805 (R-STRENG) (incorporated by reference, see § 195.3) to determine the strength of corroded pipe based on actual remaining wall thickness. These procedures apply to corroded regions that do not penetrate the pipe wall, subject to the limitations set out in the respective procedures.
[Amdt. 195-99, 80 FR 188, Jan. 5, 2015]