  • § 234.213 Grounds.

    (a) General. Except as provided in paragraph (b) of this section, each circuit that affects the proper functioning of a highway-rail grade crossing warning system shall be kept free of any ground or combination of grounds that will permit a current flow of 75 percent or more of the value necessary to retain a permissive state of a safety appliance.

    (b) Exception. Paragraph (a) of this section does not apply to the following:

    (1) Circuits that include track rail;

    (2) Alternating current power distribution circuits that are grounded in the interest of safety;

    (3) Circuitry internal to microprocessor-based appliances;

    (4) Circuitry internal to semiconductor-based memory; and

    (5) Common return wires of grounded common return single break circuits.