95-10921. Incorporation of Amendments to the International Convention for Safety of Life at Sea, 1974  

  • [Federal Register Volume 60, Number 90 (Wednesday, May 10, 1995)]
    [Rules and Regulations]
    [Pages 24767-24782]
    From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
    [FR Doc No: 95-10921]
    
    
    
    =======================================================================
    -----------------------------------------------------------------------
    
    DEPARTMENT OF TRANSPORTATION
    
    Coast Guard
    
    33 CFR Part 164
    
    46 CFR Parts 50, 52, 56, 58, 61, and 111
    
    [CGD 83-043]
    RIN 2115-AB41
    
    
    Incorporation of Amendments to the International Convention for 
    Safety of Life at Sea, 1974
    
    Agency: Coast Guard, DOT.
    
    Action: Final rule.
    
    -----------------------------------------------------------------------
    
    SUMMARY: The Coast Guard is modifying its regulations on navigational 
    safety and marine engineering to harmonize them with the International 
    Convention for the Safety of Life at Sea, 1974 (SOLAS 74), as amended, 
    and to allow the use of current technology. This final rule is 
    necessary because changes have been made to SOLAS 74 and new technology 
    has become available. The incorporation of SOLAS 74 as amended will 
    enhance the safety of personnel and vessels, protect the natural 
    environment, and contribute to domestic carriers' improved 
    competitiveness in the global market.
    
    DATES: This final rule is effective on June 9, 1995. The Director of 
    the Federal Register approves as of June 9, 1995 the incorporation by 
    reference of certain materials listed in this rule.
    
    FOR FURTHER INFORMATION CONTACT: Lieutenant Commander R.K. Butturini, 
    Engineering Branch, Marine Technical and Hazardous Materials Division, 
    Office of Marine Safety, Security and Environmental Protection, (202) 
    267-2206.
    
    SUPPLEMENTARY INFORMATION:
    
        Drafting Information: The principal persons involved in drafting 
    this final rule are Lieutenant Commander R.K. Butturini, Project 
    Manager, and Mr. Patrick J. Murray, Project Counsel, Office of Chief 
    Counsel. Regulatory History.
    
        On September 28, 1990, the Coast Guard published a notice of 
    proposed rulemaking (NPRM) entitled ``Incorporation of Amendments to 
    the International Convention for Safety of Life at Sea, 1974'' (55 FR 
    39638). The Coast Guard received three letters commenting on the NPRM. 
    No public hearing was requested, and none was held.
    
    Background and Purpose
    
        On November 1, 1974, the Assembly of the Inter-Governmental 
    Maritime Consultative Organization (IMCO) adopted SOLAS 74. In May 1982 
    IMCO was renamed the International Maritime Organization (IMO). 
    Invoking Article VIII of SOLAS 74, which contained procedures for 
    amending SOLAS 74, IMO adopted further resolutions; these resolutions 
    recommended areas of SOLAS 74 in need of improvement. The United States 
    was instrumental in the development of SOLAS 74 and its amendments.
        To date, three sets of amendments have been adopted. The first set 
    of amendments was approved by the Maritime Safety Committee (MSC) of 
    IMO on November 20, 1981, and became effective on September 1, 1984. 
    These amendments deal primarily with subdivision and stability, 
    machinery and electrical installations, periodically unattended 
    machinery spaces, and measures for fire safety. The second set of 
    amendments was approved by the MSC on June 17, 1983, and became 
    effective on July 1, 1986. These amendments deal primarily with 
    appliances and arrangements for lifesaving and with the carriage of 
    dangerous goods. The third set of amendments was approved by the MSC on 
    April 11, 1989, and became effective on February 1, 1992. These 
    amendments address amendments to SOLAS 74 that could not be included in 
    the 1983 SOLAS amendments, and include [[Page 24768]] changes to 
    requirements for bilge systems and fuel systems for machinery.
        Since the U.S. is signatory to this international treaty, periodic 
    upgrades of domestic regulations for the safety of personnel, and of 
    vessels inspected by the Coast Guard, are necessary to align our 
    regulations with SOLAS 74, as amended. Through such upgrades, these 
    regulations will come to comprise the international standards for the 
    safety of personnel and vessels at large. Generally, the amendments to 
    SOLAS 74 impose higher standards than our current regulations, and 
    these standards should lead to fewer casualties among vessels. 
    Therefore, the Coast Guard is applying the standards to all new 
    inspected vessels subject to Subchapter F, regardless of size or type 
    of voyage, except as otherwise specified in this final rule.
        This final rule adopts standards from Chapters II-1, II-2, and V of 
    SOLAS 74 contained in the first set of amendments (1981) and third set 
    of amendments (1989). This rule does not adopt standards contained in 
    the second set of amendments (1983), because they are the subject of a 
    separate rulemaking. When discussing SOLAS 74, as amended, this rule 
    will cite the applicable numbers of paragraph and regulation. For 
    example, SOLAS II-1/29.6 is the reference for Paragraph 6 of Regulation 
    29 of SOLAS Chapter II-1.
        The Coast Guard compared the SOLAS 74 amendments to 46 CFR 
    subchapter F, ``Marine Engineering''. The results appear in the 
    following table. An asterisk (*) in the table means that a requirement 
    appearing in SOLAS 74, as amended, is not now covered by subchapter F 
    but is addressed in this final rule. Since certain requirements of 
    SOLAS 74, as amended, tabulated below have already been adopted into 46 
    CFR part 62--VITAL SYSTEM AUTOMATION, they are not included in this 
    final rule.
    
    ------------------------------------------------------------------------
      1981 SOLAS                                                            
      amendments                 Corresponding U.S. regulation              
    ------------------------------------------------------------------------
    Chapter II-1.  (Cites to Title 46, Code of Federal Regulations, unless  
                    otherwise specified).                                   
    3............  Secs. 58.25*, 62.30-5.                                   
    20.2.........  Sec. 56.50-85*.                                          
    21...........  Secs. 56.50-50, 56.50-55, 62.30-5.                       
    26.1.........  Parts 52, 54, 56; Secs. 58.01-20, 58.05-1, 62.25-30.     
    26.2.........  Secs. 58.01-35, 62.25-1, 62.30-5.                        
    26.3.........  Secs. 52.01-10, 56.50-30, 56.50-35, 56.50-45, 56.50-65,  
                    56.50-80, 58.05-1, 58.01-35, 62.25-1, 62.30-5, 111.10-3,
                    111.10-5, 111.35-1, 112.05-1.                           
    26.4.........  Secs. 58.01-35, 62.30-5, 111.10-76.                      
    26.5.........  Secs. 52.01-135, 54.10, 56.95, 56.97.                    
    26.6.........  Secs. 58.01-40*, 62.20-5, 62.25-30.                      
    26.8.........  Sec. 58.05-1.                                            
    27.1.........  Secs. 58.05-1, 58.10-15, 62.25-1, 62.25-15, 111.12-1.    
    27.2.........  Secs. 52.01-120, 54.15, 56.07-10, 58.05-1.               
    27.3.........  Sec. 58.05-1.                                            
    27.4.........  Sec. 58.05-1.                                            
    27.5.........  Secs. 56.50-80, 58.05-1, 58.05-10*, 58.10-15, 62.25-1,   
                    62.25-15, 62.30-5, 62.35-5, 111.12-1.                   
    28.1.........  Sec. 58.05-5.                                            
    28.2-28.4....  33 CFR 164.35; 46 CFR 35.20-40, 78.21, 97.19.            
    29 & 30......  33 CFR 164.11*, 33 CFR 164.39*; 46 CFR Sec. 58.25*.      
    31...........  Secs. 61.40-1, 62.01-1, 62.01-3, 62.01-5, 62.20-1, 62.20-
                    3, 62.25-1, 62.25-5, 62.25-10, 62.25-20, 62.30-5, 62.30-
                    15, 62.35-5, 62.35-10, 62.50-1, 62.50-20.               
    32.1.........  Sec. 52.01-120.                                          
    32.2.........  Secs. 62.25-1, 62.35-20.                                 
    32.3.........  Sec. 52.01-110*.                                         
    32.4.........  Sec. 56.50-30.                                           
    32.5.........  Secs. 52.01-115, 56.50-30.                               
    32.6.........  Sec. 52.01-110.                                          
    33.1.........  Sec. 56.07-10.                                           
    33.2.........  Sec. 56.50-15*.                                          
    33.3.........  Secs. 56.07-10, 56.50-10, 56.50-15.                      
    34.1.........  Sec. 58.30-5.                                            
    34.2.........  Secs. 58.05-1, 58.30-534.3 Sec. 58.05-1.                 
    34.4.........  Sec. 58.30-5*.                                           
    35...........  Sec. 58.01-45*.                                          
    36...........  Sec. 58.01-50*.                                          
    37...........  Secs. 62.35-5, 113.30-5, 113.35-3.                       
    38...........  Sec. 113.27-1.                                           
    39...........  Sec. 56.50-55.                                           
    46--54.......  Secs. 61.40-1, 62.01-1, 62.01-3, 62.20-1, 62.20-3, 62.25-
                    1, 62.25-15, 62.25-20, 62.30-1, 62.30-5, 62.30-15, 62.35-
                    5, 62.35-10, 62.50-1, 62.50-20, 62.50-30.               
    Chapter II-2:                                                           
      15.1.......  Secs. 58.01-10*, 58.01-15*, 112.50-1.                    
      15.2.......  Secs. 56.10, 56.15, 56.20, 56.25, 56.30, 56.50-60*, 56.50-
                    65, 56.50-70, 56.50-75, 56.50-85*, 56.50-90*, 58.01-55*.
      15.3.......  Secs. 56.50-60*, 56.50-90*, 58.01-55*.                   
      15.4.......  Sec. 56.50-60*.                                          
      15.5.......  Secs. 62.35-40, 62.50-30.                                
      15.6.......  33 CFR 155.470.                                          
      18.1 & 18.2  Secs. 56.50-1, 56.50-5, 56.50-95.                        
      51.........  Sec. 58.16.                                              
      54.2.5.....  Sec. 56.50-50*.                                          
      59.1.6.....  Sec. 56.50-85*.                                          
    Chapter V:                                                              
      19.........  Sec. 58.25-85*.                                          
    ------------------------------------------------------------------------
    
    
    ------------------------------------------------------------------------
      1989 SOLAS                                                            
      amendments                 Corresponding U.S. regulation              
    ------------------------------------------------------------------------
    Chapter II-1.  (Cites to Title 46, Code of Federal Regulations, unless  
                    otherwise specified).                                   
    21.1.6.......  Sec. 56.50-50*.                                          
    21.2.9.......  Sec. 56.50-50*.                                          
    Chapter II-2:                                                           
      15.2.6.....  Secs. 56.50-60*, 56.50-90*.                              
      15.3.......  Secs. 56.50-80*, 56.50-90*.                              
    Chapter V:                                                              
      12.........  33 CFR 164.35*.                                          
    ------------------------------------------------------------------------
    
        A final rule concerning Intervals for Drydocking and Tailshaft 
    Examination on Inspected Vessels [CGD 84-024] went into effect on 
    September 23, 1988. It changed the interval for drydocking vessels from 
    one inspection every two years to inspections in multiples of thirty 
    months (i.e., two inspections within any five-year period, except that 
    no more than three years may elapse between any inspection and its 
    immediate predecessor). But it left the interval for inspecting major 
    machinery at two years. Because of this continued misalignment of 
    inspection intervals for drydockings and major machinery, that rule 
    causes a hardship for owners of some vessels. The most opportune time 
    for inspecting major machinery--boilers and pressure vessels--is during 
    drydocking, when the machinery is secured. This final rule allows 
    intervals for inspecting major machinery to coincide with those for 
    drydocking. The inspection interval has not been changed for those 
    cases where inspection of machinery does not depend on the vessels' 
    being drydocked.
        There have been continuing proposals by designers of vessels, by 
    shipyards, and by shipowners for the use of nonmetallic piping in 
    concealed spaces aboard ship. Current domestic regulations prohibit 
    this use of nonmetallic piping unless the piping is within trunks 
    completely surrounded by ``A'' class divisions. SOLAS 74, as amended, 
    does not preclude this use of nonmetallic piping, while classification 
    societies, as well as the International Association of Classification 
    Societies, permit it. Therefore, this final rule provides alternative 
    requirements for piping in concealed spaces and permits the 
    installation of nonmetallic piping under certain restrictions. The 
    change [[Page 24769]] will reduce the costs of constructing vessels.
        Current domestic regulations require certain cargo ships to have 
    three powered bilge pumps. SOLAS 74, as amended, and many 
    classification societies have successfully permitted these ships to 
    have only two powered bilge pumps. This final rule aligns domestic 
    regulations with SOLAS 74. The change will reduce the costs of 
    outfitting U.S.-flag vessels.
        For many years domestic regulations have also required each 
    individual bilge suction to be led from one or more manifolds located 
    within the same space as the bilge pump. In the early 1970s, the Coast 
    Guard developed regulations permitting common-rail bilge and ballast 
    systems for cargo spaces on multi-purpose bulk carriers that can lift 
    combinations of both liquid and dry bulk cargoes (O/B/O) and that ply 
    the Great Lakes. Since then, several designers of vessels have asked to 
    install common-rail bilge systems on cargo and passenger vessels. The 
    Coast Guard has, by policy, accepted all of these systems provided they 
    satisfied certain other design restrictions. The main concern with 
    accepting any of them is the risk of losing suction for the entire 
    system if the common line fails or leaks. The additional criteria 
    reduce that risk and make the system equivalent to the conventional 
    manifold system. Such a common-rail system is acceptable under SOLAS 
    74, as amended. This final rule permits these systems on all vessels as 
    an equivalent alternative to the existing requirements for manifold 
    systems.
        Until now, domestic regulations have required, for all vessels 
    subject to 46 CFR subchapter F and not fitted with an auxiliary means 
    of steering, dual-power hydraulic steering apparatus having two 
    independent pumps and connections. Each independent steering-gear power 
    unit must be capable of meeting the rudder-movement standard of 35 deg. 
    on one side to 30 deg. on the other side in not more than 28 seconds. 
    These regulations are not consistent with the 1981 amendments to SOLAS 
    74. For passenger vessels without auxiliary steering systems, SOLAS 74, 
    as amended, requires that main steering gear, consisting of two or more 
    identical power units, be capable of meeting the same rudder-movement 
    standard with any one unit out of service. For cargo vessels without 
    auxiliary steering systems, SOLAS 74, as amended, requires that main 
    steering gear be capable of meeting the same rudder-movement standard 
    with all power units in service. The Coast Guard does not consider the 
    1981 amendments to SOLAS 74 to compromise the safety of the vessel, and 
    therefore, by this final rule, modifies current regulations for dual-
    power hydraulic steering apparatus to coincide with SOLAS 74, as 
    amended.
    
    Discussion of Comments and Changes
    
        A total of three comment letters were received. The letters were 
    supportive of the efforts by the Coast Guard to incorporate industry 
    standards by reference. Two letters also offered specified comments on 
    individual sections of the proposed rule. The third letter simply 
    endorsed the comments of one of the first two letters. Additionally, 
    the Coast Guard received recommendations from the National 
    Transportation Safety Board (NTSB) asking for clarification of one of 
    the regulations modified in the proposed rules. The sections of the 
    proposed rule to which comments were addressed are discussed below, as 
    are each comment and the Coast Guard's response.
    
    1. 33 CFR 164.11(t)
    
        The proposed rule implements the standards of SOLAS 74 II-1/29.6 
    and II-1/29.15. Current paragraph (t) requires that, while a vessel is 
    under way on the navigable waters of the U.S., except the St. Lawrence 
    Seaway, at least two of the steering-gear power units be in operation 
    when the units are capable of simultaneous operation. That paragraph 
    embodies SOLAS 74 V/19-1. SOLAS 74 II-1/29.6 and II-1/29.15 impose a 
    performance standard on steering-gear systems. A combination of power 
    units may be operated simultaneously to meet the performance standard 
    of moving the rudder from 35 deg. on one side to 30 deg. on the other 
    side in not more than 28 seconds.
        The NTSB's recommendations arose from the grounding of the MOBILOIL 
    in 1985 and the collision of the MANDAN with moored barges in 1990. 
    Both casualties involved loss of steering. The recommendations called 
    for clarification of current Sec. 164.11(t).
        The Coast Guard agrees with the need for clarity and therefore both 
    revises proposed Sec. 164.11(t) and adds Sec. 164.11(u). Revised 
    Sec. 164.11(t) applies to both foreign and domestic vessels and 
    requires the operation of at least two steering-gear power units when 
    the power units are designed for simultaneous operation. Excepted from 
    this requirement are vessels on the Great Lakes and vessels covered by 
    Sec. 164.11(u). New Sec. 164.11(u) applies to newer foreign and 
    domestic vessels and, consistent with SOLAS 74, as amended, imposes a 
    standard of performance instead of a specification of design.
    
    2. 46 CFR 56.50-50
    
        This section was intended by the proposed rule to implement the 
    standards of SOLAS 74 II-2/54.2.5. Paragraph (a)(4) requires that bilge 
    systems, when they serve enclosed cargo spaces carrying flammable or 
    toxic liquids, be designed to prevent the inadvertent pumping of 
    flammable or toxic liquids through machinery-space piping or pumps.
        One comment suggested that the final rule also address Class 8 
    dangerous goods because SOLAS 74 II-2/54.2.5 applies to these goods as 
    well.
        The Coast Guard agrees with the comment as consistent with the 
    intent of the proposed rule and has included the reference to Class 8 
    dangerous liquids with a flashpoint below 23 deg.C (74 deg.F) in this 
    final rule. In addition, since SOLAS applies the flashpoint limit to 
    the Class 3 flammable liquids, the Coast Guard also applies it to them.
        One comment suggested stipulating a specific minimal quantity of 
    dangerous goods, which would require invoking the proposed change to 
    this section.
        The Coast Guard disagrees with this comment since there is no 
    similar approach in the standard of SOLAS on which it is based. 
    Further, it would be difficult to stipulate a specific minimal quantity 
    of dangerous goods that would not need regulation.
        One comment suggested calling the machinery space the ``main 
    machinery'' space.
        The Coast Guard disagrees with the comment since this would change 
    the applicability of the section. Such a narrow interpretation of SOLAS 
    74 in this regard is unwarranted. The rules will continue to use the 
    terminology of SOLAS 74.
    
    3. 46 CFR 56.60-25
    
        This section was intended by the proposed rule to codify current 
    Coast Guard policy. Paragraph (a) allows the use of nonmetallic piping 
    for nonvital freshwater and saltwater service, to run in concealed 
    spaces. The Coast Guard has allowed this use, considering further 
    design criteria, such as the fire integrity of bulkheads, the proper 
    maintenance of decks and draft stops, or the installation in the 
    concealed space of an approved smoke-detection system. Current 
    regulations require this piping to be of metallic construction or to be 
    nonmetallic piping surrounded by ``A'' class divisions. SOLAS 74, as 
    amended, does not preclude nonmetallic piping for this use.
        One comment suggested recognizing CPVC and polybutylene as 
    acceptable materials under this section because of their extensive use 
    elsewhere. [[Page 24770]] 
        The Coast Guard agrees that much progress is being made in the 
    evaluation and testing of plastic materials for piping and that 
    expanding the acceptance of these materials in Coast Guard regulations 
    should be addressed. The Coast Guard feels, however, that this comment 
    goes beyond the scope of this final rule. CPVC and polybutylene will be 
    further evaluated, and addressed in a future rulemaking. Moreover, IMO 
    is currently working on specific guidelines for the acceptance of these 
    materials, and further developments on the topic will affect Coast 
    Guard policy on these materials. Current regulations do not preclude 
    the use of materials not meeting ASTM F1173. The requirements for the 
    use of these materials appear in current Sec. 56.60-25(a)(10).
        One comment suggested that the use, along with plastic piping, of 
    metallic spool pieces at all bulkhead penetrations would be equivalent 
    to requiring a smoke-detection system in concealed accommodation or 
    service spaces.
        The Coast Guard disagrees with this comment. The early detection of 
    fires or smoke in concealed spaces is vital, and metallic spool pieces 
    do not enable it.
        One comment suggested clarification of Sec. 56.60-25(a)(3)(i) to 
    clearly allow the use of plastic piping outside trunks or ducts if 
    inside a concealed space within ``A'' class boundaries.
        The Coast Guard disagrees with this comment. Under the comment's 
    definition, a concealed space spanning several ``B'' class boundaries 
    could have plastic piping as long as ``A'' class boundaries surround 
    the overall space. The wording in the proposed rule has not been 
    changed.
        One comment suggested allowing smoke detectors, located adjacent to 
    but not in the concealed space, to replace required detectors in the 
    space.
        The Coast Guard disagrees with this comment, which assumes that a 
    fire would never start in a concealed space with plastic piping but 
    that any fire would come from the adjacent space. The burning of the 
    plastic piping in a concealed space is the concern, and the sensors 
    should be located so as to most readily detect the concealed fire. The 
    requirement for sensors in the concealed space as stated in the 
    proposed rule remains.
    
    4. 46 CFR 58.25-65
    
        This section was intended by the proposed rule to move, from 
    subchapter J to subchapter F, requirements applicable to steering 
    systems. Paragraphs (a) through (d) simply restate requirements from 
    current 46 CFR 111.93-7 that cover feeder circuits serving electric-
    driven steering-gear power units. This section reflects interpretations 
    by the Coast Guard of applicable requirements in SOLAS 74 II-1/29.14 
    and II-1/30.2.
        One comment suggested that use of the size of the rudder stock as a 
    criterion for determining whether one of the electrical feeders should 
    be supplied from an alternative source of power was ambiguous. The 
    comment further suggested use of some other, more definite criterion, 
    such as number of passengers or gross tonnage.
        The size of the rudder stock closely correlates with the overall 
    size and speed of the vessel, and use of it as a criterion comes from 
    SOLAS 74 II-1/29.14. Because this regulation applies to both cargo and 
    passenger vessels, making the number of passengers the criterion would 
    be inappropriate.
        The Coast Guard has found gross tonnage to be unreliable when used 
    for drawing regulatory lines. Besides, the intent of the final rule is 
    to harmonize regulations of the Coast Guard with standards of SOLAS, 
    not to impose requirements that exceed those of SOLAS. Since this part 
    of the proposed rule does not deviate from current regulations and will 
    not cause a burden on industry, it has not been changed.
    
    5. 46 CFR 61.05-10
    
        This section was intended by the proposed rule to change Table 
    61.05-10 and Sec. Sec. 61.05-10, 61.05-15, 61.05-20, 61.10-5, and 
    61.15-5, aligning intervals for inspections and tests of major 
    machinery with new intervals for drydockings of vessels. Generally, 
    current regulations require inspections of major machinery, such as 
    pressure vessels and boilers, in two-year multiples, to coincide with a 
    vessel's regular inspection for certification. Numerous owners and 
    operators have insisted that such scheduling creates an economic 
    hardship since an inspection for certification is not always the 
    appropriate time for an inspection of a boiler or a pressure vessel. 
    Rather, these owners and operators suggest, the intervals for 
    drydockings are more appropriate as the intervals also for such 
    inspections and tests of major machinery. The Coast Guard agrees and 
    has proposed that inspections of major machinery occur, like 
    drydockings, at a rate of two inspections in any five-year period, with 
    no more than three years between any inspection and its immediate 
    predecessor. Also, a new Table 61.05-10 collects into a single table 
    the intervals for all inspections and tests of boilers, except of 
    automation controls. Since this should decrease a vessel's time out of 
    service, the owners and operators should realize economic savings.
        One comment suggested defining ``hybrid boilers'' as used in Note 3 
    to Table 61.05-10.
        The Coast Guard defines ``hybrid boilers'' as boilers that employ 
    design features from both traditional watertube and firetube boilers. 
    This final rule defines them so in Sec. 52.01-3.
    
    Incorporation by Reference
    
        The Director of the Federal Register has approved the materials 
    listed in 33 CFR 164.03 and 46 CFR 58.03-1(b) for incorporation by 
    reference under 5 U.S.C. 552 and 1 CFR part 51. The materials are 
    available as indicated in those sections.
    
    Regulatory Evaluation
    
        This final rule is not a significant regulatory action under 
    section 3(f) of Executive Order 12866 and does not require an 
    assessment of potential costs and benefits under section 6(a)(3) of 
    that Order. It has not been reviewed by the Office of Management and 
    Budget under that Order. It is not significant under the regulatory 
    policies and procedures of the Department of Transportation (44 FR 
    11034 (February 26, 1979)). The Coast Guard expects the economic impact 
    of this final rule to be so minimal that a full Regulatory Assessment 
    is unnecessary. The net benefits due to savings from this rule should 
    outweigh the burden.
        As discussed in Background and Purpose, above, the main purpose of 
    this final rule is to incorporate into domestic regulations amendments 
    to the International Convention for Safety of Life at Sea, 1974, 
    addressing issues of marine engineering. U.S.-flag cargo and tank 
    vessels of 500 gross tons and more, and passenger vessels carrying more 
    than twelve passengers and engaged on international voyages, already 
    must comply with SOLAS 74, as amended. Thus, this rule will have no 
    economic impact on these vessels. This rule does, however, affect 
    vessels that need not yet comply with SOLAS 74, as amended, as such, 
    since the Coast Guard, in general, is applying the standards of the 
    treaty to all new domestic vessels subject to subchapter F.
        Although some of the changes due to SOLAS 74 will result in minor 
    increases in cost, others will result in savings that more than offset 
    these increases. Many of the changes reflect current practice of the 
    marine industry or can be integrated readily into the design of the 
    vessel before construction and will place no direct burden on the 
    industry. The changes that will place the greatest 
    [[Page 24771]] economic burden upon the industry affect steering gear. 
    However, the increase in cost associated with accomplishing the changes 
    represents a small fraction of the total cost for a steering system and 
    should be offset by the savings anticipated from the reduction in the 
    number and cost of casualties.
        The remaining changes in this final rule are not due to SOLAS 74: 
    Greater use of common-rail bilge systems, an increase in the inspection 
    interval for major machinery, and greater use of plastic piping in 
    concealed spaces. These changes will bring only savings to the marine 
    industry. On the bilge system and on plastic piping, this rule permits, 
    without reducing safety, attractive alternatives to the expensive means 
    required by the current regulations. Also, by enlarging the interval 
    for inspection of major machinery, to make the inspection coincide with 
    the vessel's drydocking, this rule will reduce the number of 
    inspections over a vessel's life and reduce the vessel's time out of 
    service, all resulting in long-term savings to the owner.
    
    Small Entities
    
        This final rule will apply to owners and operators of commercial 
    vessels registered in the U.S. Few of these, if any, qualify as small 
    entities. Again, the economic impact of this rule on individual owners 
    and operators should be minimal. Therefore, the Coast Guard certifies 
    under section 605 of the Regulatory Flexibility Act (5 U.S.C. 601 et 
    seq.) that this rule will not have a significant economic impact on a 
    substantial number of small entities.
    
    Collection of Information
    
        This final rule imposes on the public no new or added requirements 
    for collecting information under the Paperwork Reduction Act (44 U.S.C. 
    3501 et seq.). In particular, it does not change any such requirements 
    in 33 CFR part 164 or 46 CFR part 50, 52, 56, 58, 61, or 111.
    
    Environment
    
        The Coast Guard has considered the environmental impact of this 
    final rule and concluded that, under section 2.B.2.c of Commandant 
    Instruction M16475.1B, this rule is categorically excluded from further 
    treatment in environmental documents. A Categorical-Exclusion 
    Determination is available in the docket for inspection or copying 
    where indicated under addresses.
    
    Federalism
    
        The Coast Guard has analyzed this final rule in accordance with the 
    principles and criteria of Executive Order 12612 and has determined 
    that this rule does not have sufficient implications for federalism to 
    warrant the preparation of a Federalism Assessment. The authority to 
    issue regulations on the navigational safety of the vessels covered by 
    this rule is committed to the Coast Guard by Federal statute. 
    Therefore, the Coast Guard intends to preempt State or local laws on 
    the navigational safety of these vessels.
    
    List of Subjects
    
    33 CFR Part 164
    
        Incorporation by reference, Marine safety, Navigation (water), 
    Reporting and recordkeeping requirements, Waterways.
    
    46 CFR Part 50
    
        Reporting and recordkeeping requirements, Vessels.
    
    46 CFR Part 52
    
        Reporting and recordkeeping requirements, Vessels.
    
    46 CFR Part 56
    
        Reporting and recordkeeping requirements, Vessels.
    
    46 CFR Part 58
    
        Incorporation by reference, Reporting and recordkeeping 
    requirements, Vessels.
    
    46 CFR Part 61
    
        Reporting and recordkeeping requirements, Vessels.
    
    46 CFR Part 111
    
        Reporting and recordkeeping requirements, Vessels.
    
        For the reasons set out in the preamble, the Coast Guard amends 
    Title 33, part 164, and Title 46, parts 50, 52, 56, 58, 61, and 111, of 
    the Code of Federal Regulations, as follows:
    
    Title 33--[Amended]
    
    PART 164--NAVIGATION SAFETY REGULATIONS
    
        1. The authority citation for part 164 continues to read as 
    follows:
    
        Authority: 33 U.S.C. 1223, 46 U.S.C. 3703; 49 CFR 1.46(n). Sec. 
    164.61 also issued under 46 U.S.C. 6101.
    
        2. Section 164.03 is amended by revising paragraph (b) to read as 
    follows:
    
    
    Sec. 164.03  Incorporation by reference.
    
    * * * * *
        (b) The materials approved for incorporation by reference in this 
    part, and the sections affected, are:
    
    Radio Technical Commission for Marine Services, P.O. Box 19087, 
    Washington, DC 20036, Paper 12/78/DO-100 Minimum Performance 
    Standards, Loran C Receiving Equipment, 1977--164.41
    International Maritime Organization, 4 Albert Embankment, London SE1 
    7SR U.K., IMO Resolution A.342(IX), Recommendation on Performance 
    Standards for Automatic Pilots, adopted November 12, 1975--164.13.
    
        3. Section 164.11 is amended by revising its heading and paragraph 
    (t) and by adding paragraph (u) to read as follows:
    
    
    Sec. 164.11  Navigation under way: General.
    
    * * * * *
        (t) At least two of the steering-gear power units on the vessel are 
    in operation when such units are capable of simultaneous operation, 
    except when the vessel is sailing on the Great Lakes and their 
    connecting and tributary waters, and except as required by paragraph 
    (u) of this section.
        (u) On each passenger vessel meeting the requirements of the 
    International Convention for the Safety of Life at Sea, 1960 (SOLAS 60) 
    and on each cargo vessel meeting the requirements of SOLAS 74 as 
    amended in 1981, the number of steering-gear power units necessary to 
    move the rudder from 35 deg. on either side to 30 deg. on the other in 
    not more than 28 seconds must be in simultaneous operation.
        4. Section 164.35 is amended by adding paragraph (o) to read as 
    follows:
    
    
    Sec. 164.35  Equipment: All vessels.
    
    * * * * *
        (o) A telephone or other means of communication for relaying 
    headings to the emergency steering station. Also, each vessel of 500 
    gross tons and over and constructed on or after June 9, 1991 must be 
    provided with arrangements for supplying visual compass-readings to the 
    emergency steering station.
        5. Section 164.39 is revised to read as follows:
    
    
    Sec. 164.39  Steering gear: Foreign tankers.
    
        (a) This section applies to each foreign tanker of 10,000 gross 
    tons or more, except a public vessel, that--
        (1) Transfers oil at a port or place subject to the jurisdiction of 
    the United States; or
        (2) Otherwise enters or operates in the navigable waters of the 
    United States, except a vessel described by Sec. 164.02 of this part.
        (b) Definitions. The terms used in this section are as follows: 
    [[Page 24772]] 
        Constructed means the same as in Chapter II-1, Regulations 1.1.2 
    and 1.1.3.1, of SOLAS 74.
        Existing tanker means a tanker--
        (1) For which the building contract is placed on or after June 1, 
    1979;
        (2) In the absence of a building contract, the keel of which is 
    laid or which is at a similar stage of construction on or after January 
    1, 1980;
        (3) The delivery of which occurs on or after June 1, 1982; or
        (4) That has undergone a major conversion contracted for on or 
    after June 1, 1979; or construction of which was begun on or after 
    January 1, 1980, or completed on or after June 1, 1982.
        Public vessel, oil, hazardous materials, and foreign vessel mean 
    the same as in 46 U.S.C. 2101.
        SOLAS 74 means the International Convention for the Safety of Life 
    at Sea, 1974, as amended.
        Tanker means a self-propelled vessel defined as a tanker by 46 
    U.S.C. 2101(38) or as a tank vessel by 46 U.S.C. 2101(39).
        (c) Each tanker constructed on or after September 1, 1984, must 
    meet the applicable requirements of Chapter II-1, Regulations 29 and 
    30, of SOLAS 74.
        (d) Each tanker constructed before September 1, 1984, must meet the 
    requirements of Chapter II-1, Regulation 29.19, of SOLAS 74.
        (e) Each tanker of 40,000 gross tons or more, constructed before 
    September 1, 1984, that does not meet the single-failure criterion of 
    Chapter II-1, Regulation 29.16, of SOLAS 74, must meet the requirements 
    of Chapter II-1, Regulation 29.20, of SOLAS 74.
        (f) Each tanker constructed before September 1, 1984, must meet the 
    applicable requirements of Chapter II-1, Regulations 29.14 and 29.15, 
    of SOLAS 74.
    
    Title 46--[Amended]
    
    PART 50--GENERAL PROVISIONS
    
        6. The authority citation for part 50 is revised to read as 
    follows:
    
        Authority: 43 U.S.C. 1333; 46 U.S.C. 2103, 3306, 3703; E.O. 
    12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; 49 CFR 1.45, 1.46. 
    Section 50.01-20 also issued under the authority of 44 U.S.C. 3507.
    
        7. Subpart 50.10 is amended by adding Sec. 50.10-35 to read as 
    follows:
    
    
    Sec. 50.10-35  Constructed.
    
        The term constructed means the keel has been laid or, for vessels 
    with no keel, assembly of at least 50 tons or 1% of the estimated mass 
    of all structural material, whichever is less, has been completed.
    
    PART 52--POWER BOILERS
    
        8. The authority citation for part 52 continues to read as follows:
    
        Authority: 46 U.S.C. 3306, 2103, 3703; E.O. 12234, 45 FR 58801, 
    3 CFR, 1980 Comp., p. 277; 49 CFR 1.46.
    
        9. Section 52.01-3 is amended by adding paragraph (a)(10) to read 
    as follows:
    
    
    Sec. 52.01-3  Definitions of terms used in this part.
    
        (a) * * *
        (10) Hybrid boiler. A hybrid boiler is a steam boiler whose design 
    employs features from both watertube and firetube boilers.
    * * * * *
        10. Section 52.01-110 is amended by revising its heading and adding 
    paragraph (h) to read as follows:
    
    
    Sec. 52.01-110  Water-level indicators, water columns, gauge-glass 
    connections, gauge cocks, and pressure gauges (modifies PG-60).
    
    * * * * *
        (h) High-water-level alarm. Each watertube boiler for propulsion 
    must have an audible and a visible high-water-level alarm. The alarm 
    indicators must be located where the boiler is controlled.
    
    PART 56--PIPING SYSTEMS AND APPURTENANCES
    
        11. The authority citation for part 56 is revised to read as 
    follows:
    
        Authority: 33 U.S.C. 1321(j), 1509; 43 U.S.C. 1333; 46 U.S.C. 
    2103, 3306, 3703; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 
    277; E.O. 12777, 56 FR 54757; 49 CFR 1.46.
    
        12. Section 56.15-5 is amended by revising its heading and 
    paragraph (c)(1)(ii) to read as follows:
    
    
    Sec. 56.15-5  Fluid-conditioner fittings.
    
    * * * * *
        (c) * * *
        (1) * * *
        (ii) Nonstandard fluid-conditioner fittings that have an internal 
    diameter exceeding 15 centimeters (6 inches) and that are rated for 
    temperatures and pressures exceeding those specified as minimums for 
    Class I piping systems.
    * * * * *
        13. Section 56.30-25 is amended by adding a note after paragraph 
    (f)(2) to read as follows:
    
    
    Sec. 56.30-25  Flared, flareless, and compression joints.
    
    * * * * *
        (f) * * *
        (2) * * *
    
        Note--See Sec. 58.25-20(d) of this subchapter for limitations on 
    the use of compression fittings in hydraulic systems for steering 
    gear.
    
        14. Section 56.50-15 is amended by adding paragraph (k) to read as 
    follows:
    
    
    Sec. 56.50-15  Steam and exhaust piping.
    
    * * * * *
        (k) Means must be provided for draining every steam pipe in which 
    dangerous water hammer might otherwise occur.
        15. Section 56.50-50 is amended by adding paragraphs (a)(4), 
    (a)(5), and (c)(4), revising paragraphs (c)(1), (c)(2), and the 
    definition for ``D'' and adding a Note 6 in paragraph (d)(2), and 
    revising the last sentence of paragraph (h) to read as follows:
    
    
    Sec. 56.50-50  Bilge and ballast piping.
    
        (a) * * *
        (4) Where the vessel is to carry Class 3 flammable liquids with a 
    flashpoint below 23 deg.C (74 deg.F), Class 6, Division 6.1, poisonous 
    liquids, or Class 8 corrosive liquids with a flashpoint below 23 deg.C 
    (74 deg.F) as defined in 49 CFR part 173, in enclosed cargo spaces, the 
    bilge-pumping system must be designed to ensure against inadvertent 
    pumping of such liquids through machinery-space piping or pumps.
        (5) For each vessel constructed on or after June 9, 1995, and on an 
    international voyage, arrangements must be made to drain the enclosed 
    cargo spaces on either the bulkhead deck of a passenger vessel or the 
    freeboard deck of a cargo vessel.
        (i) If the deck edge, at the bulkhead deck of a passenger vessel or 
    the freeboard deck of a cargo vessel, is immersed when the vessel heels 
    5 deg. or less, the drainage of the enclosed cargo spaces must 
    discharge to a space, or spaces, of adequate capacity, each of which 
    has a high-water-level alarm and a means to discharge overboard. The 
    number, size and arrangement of the drains must prevent unreasonable 
    accumulation of water. The pumping arrangements must take into account 
    the requirements for any fixed manual or automatic sprinkling system. 
    In enclosed cargo spaces fitted with carbon-dioxide extinguishing 
    systems, the drains must have traps or other means to prevent escape of 
    the smothering gas. The enclosed cargo spaces must not drain to 
    machinery spaces or other spaces where sources of ignition may be 
    present if water may be contaminated with Class 3 flammable liquids; 
    Class 6, Division 6.1, poisonous liquids; or Class 8 corrosive liquids 
    with a flashpoint below 23 deg.C (74 deg.F).
        (ii) If the deck edge, at the bulkhead deck of a passenger vessel 
    or the [[Page 24773]] freeboard deck of a cargo vessel, is immersed 
    only when the vessel heels more than 5 deg., the drainage of the 
    enclosed cargo spaces may be by means of a sufficient number of 
    scuppers discharging overboard. The installation of scuppers must 
    comply with Sec. 42.15-60 of this chapter.
    * * * * *
        (c)(1) Each bilge suction must lead from a manifold except as 
    otherwise approved by the Commanding Officer, Marine Safety Center. As 
    far as practicable, each manifold must be in, or be capable of remote 
    operation from, the same space as the bilge pump that normally takes 
    suction on that manifold. In either case, the manifold must be capable 
    of being locally controlled from above the floorplates and must be 
    easily accessible at all times. As far as practicable, each overboard-
    discharge valve for a bilge system must comply with the requirements 
    governing location and accessibility for suction manifolds. Except as 
    otherwise permitted by paragraph (c)(4) of this section for a vessel 
    employing a common-rail bilge system, each bilge-manifold valve 
    controlling a bilge suction from any compartment must be of the stop-
    check type.
        (2) Each passenger vessel on an international voyage must have 
    manifolds, where installed, and valves in the bilge-pumping system 
    arranged so that, in case of flooding, one of the bilge pumps can take 
    suction from any compartment and, further, so that damage to a pump or 
    its piping connecting to the bilge main outboard of a line drawn at 
    one-fifth of the beam of the vessel will not render the bilge system 
    inoperative.
    * * * * *
        (4) A common-rail bilge system may be installed as an acceptable 
    alternative to the system required by paragraph (c)(1) of this section, 
    provided it satisfies all of the following criteria:
        (i) The common-rail main runs inboard at least one-fifth of the 
    beam of the vessel.
        (ii) A stop-check valve or both a stop valve and a check valve are 
    provided in each branch line and located inboard at least one-fifth of 
    the beam of the vessel.
        (iii) The stop valve or the stop-check valve is power-driven, is 
    capable of remote operation from the space where the pump is, and, 
    regardless of the status of the power system, is capable of manual 
    operation to both open and close the valve.
        (iv) The stop valve or the stop-check valve is accessible for both 
    manual operation and repair under all operating conditions, and the 
    space used for access contains no expansion joint or flexible coupling 
    that, upon failure, would cause flooding and prevent access to the 
    valve.
        (v) A port and a starboard suction serve each space protected 
    unless, under the worst conditions of list and trim and with liquid 
    remaining after pumping, the vessel's stability remains acceptable, in 
    accordance with subchapter S of this chapter.
        (vi) For each vessel designed for the carriage of combinations of 
    both liquid and dry bulk cargoes (O/B/O), no bilge pump or piping is 
    located in a machinery space other than in a pump room for cargo, and 
    no liquid and other cargoes are carried simultaneously.
        (vii) For each cargo vessel in Great Lakes service, each common-
    rail piping for the bilge and ballast system serving cargo spaces, if 
    installed and if connected to a dedicated common-rail bilge system, 
    must lead separately from a valved manifold located at the pump.
    * * * * *
        (d) * * *
        D=Molded depth (in feet) to the bulkhead deck.(6)
    * * * * *
        Note 6--For each passenger vessel constructed on or after June 
    9, 1995, and being on an international voyage, D must be measured to 
    the next deck above the bulkhead deck if an enclosed cargo space on 
    the bulkhead deck that is internally drained in accordance with 
    paragraph (a)(4) of this section extends the entire length of the 
    vessel. Where the enclosed cargo space extends a lesser length, D 
    must be taken as the sum of the molded depth (in feet) to the 
    bulkhead deck plus lh/L where l and h are the aggregate length and 
    height (in feet) of the enclosed cargo space.
    * * * * *
        (h) Except as allowed by paragraph (c)(4)(vii) of this section, 
    piping for draining a cargo hold or machinery space must be separate 
    from piping used for filling or emptying any tank where water or oil is 
    carried. Piping for bilge and ballast must be arranged so as to 
    prevent, by the appropriate installation of stop and non-return valves, 
    oil or water from the sea or ballast spaces from passing into a cargo 
    hold or machinery space, or from passing from one compartment to 
    another, regardless of the source. The bilge and ballast mains must be 
    fitted with separate control valves at the pumps.
    * * * * *
        16. Section 56.50-55 is amended by revising paragraph (a) and Table 
    56.50-55(a) to read as follows:
    
    
    Sec. 56.50-55  Bilge pumps.
    
        (a) Self-propelled vessels. (1) Each self-propelled vessel must be 
    provided with a power-driven pump or pumps connected to the bilge main 
    as required by Table 56.50-55(a).
    
                        Table 56.50-55(a).--Power Bilge Pumps Required for Self-Propelled Vessels                   
    ----------------------------------------------------------------------------------------------------------------
                                             Passenger vessels\1\         Dry-cargo vessels\2\     Tank      Mobile 
                                    -----------------------------------------------------------  vessels    offshore
                                                      Ocean,                Ocean,             -----------  drilling
         Vessel length, in feet                       coast-                coast-                           units  
                                     International   wise and  All other   wise and     All        All    ----------
                                       voyages\3\     Great      waters     Great      waters     waters      All   
                                                      Lakes                 Lakes                            waters 
    ----------------------------------------------------------------------------------------------------------------
    180' or more...................         \4\3         \4\3          2          2          2          2          2
    Below 180' and exceeding 65'...         \4\3         \5\2       \5\2       \5\2       \5\2          2          2
    65' or less....................            3            1          1          1          1          1  .........
    ----------------------------------------------------------------------------------------------------------------
    \1\Small passenger vessels under 100 gross tons refer to Subpart 182.25 of Subchapter T (Small Passenger Vessel)
      of this chapter.                                                                                              
    \2\Dry-bulk carriers having ballast pumps connected to the tanks outside the engineroom and to the cargo hold   
      may substitute the appropriate requirements for tank vessels.                                                 
    \3\Not applicable to passenger vessels which do not proceed more than 20 mile from the nearest land, or which   
      are employed in the carriage of large numbers of unberthed passengers in special trades.                      
    \4\When the criterion numeral exceeds 30, an additional independent power-driven pump is required. (See Part 171
      of this chapter for determination of criterion numeral.)                                                      
    \5\Vessels operating on lakes (including Great Lakes), bays, sounds, or rivers where steam is always available, 
      or where a suitable water supply is available from a power-driven pump of adequate pressure and capacity, may 
      substitute siphons or eductors for one of the required power-driven pumps, provided a siphon or eductor is    
      permanently installed in each hold or compartment.                                                            
    
    [[Page 24774]] * * * * *
        17. Section 56.50-60 is amended by revising paragraphs (b) and (l) 
    and by adding paragraphs (d)(1) (i), (m), and (n) to read as follows:
    
    
    Sec. 56.50-60  Systems containing oil.
    
    * * * * *
        (b) When oil needs to be heated to lower its viscosity, heating 
    coils must be properly installed in each tank.
        (1) Each drain from a heating coil as well as each drain from an 
    oil heater must run to an open inspection tank or other suitable oil 
    detector before returning to the feed system.
        (2) As far as practicable, no part of the fuel-oil system 
    containing heated oil under pressure exceeding 180 KPa (26 psi) may be 
    placed in a concealed position so that defects and leakage cannot be 
    readily observed. Each machinery space containing a part of the system 
    must be adequately illuminated.
    * * * * *
        (d) * * *
        (1) * * *
        (i) In the special case of a deep tank in any shaft tunnel, piping 
    tunnel, or similar space, one or more valves must be fitted on the 
    tank, but control in the event of fire may be effected by means of an 
    additional valve on the piping outside the tunnel or similar space. Any 
    such additional valve installed inside a machinery space must be 
    capable of being operated from outside this space.
        (ii) [Reserved]
    * * * * *
        (l) Where oil piping passes through a non-oil tank without stop 
    valves complying with paragraph (d) of this section installed at all 
    tank penetrations, the piping must comply with Sec. 56.50-50(k).
        (m) Each arrangement for the storage, distribution, and use of oil 
    in a pressure-lubrication system must--
        (1) As well as comply with Sec. 56.50-80, be such as to ensure the 
    safety of the vessel and all persons aboard; and
        (2) In a machinery space, meet the applicable requirements of 
    Secs. 56.50-60 (b)(2) and (d), 56.50-85(a)(11), 56.50-90 (c) and (d), 
    and 58.01-55(f) of this subchapter. No arrangement need comply with 
    Sec. 58.50-90 (c)(1) and (c)(3) of this subchapter if the sounding pipe 
    is fitted with an effective means of closure, such as a threaded cap or 
    plug or other means acceptable to the Officer in Charge, Marine 
    Inspection. The use of flexible piping or hose is permitted in 
    accordance with the applicable requirements of Secs. 56.35-10, 56.35-
    15, and 56.60-25(c).
        (n) Each arrangement for the storage, distribution, and use of any 
    other flammable oil employed under pressure in a power transmission-
    system, control and activating system, or heating system must be such 
    as to ensure the safety of the vessel and all persons aboard by--
        (1) Complying with Subpart 58.30 of this subchapter; and,
        (2) Where means of ignition are present, meeting the applicable 
    requirements of Secs. 56.50-85(a)(11), 56.50-90 (c) and (d), and 58.01-
    55(f) of this subchapter. Each pipe and its valves and fittings must be 
    of steel or other approved material, except that the use of flexible 
    piping or hose is permitted in accordance with the applicable 
    requirements of Secs. 56.35-10, 56.35-15, and 56.60-25(c).
        18. Section 56.50-65 is amended by revising its heading and 
    paragraph (h) to read as follows:
    
    
    Sec. 56.50-65  Burner fuel-oil service systems.
    
    * * * * *
        (h) Each fuel-oil service pump must be equipped with controls as 
    required by Sec. 58.01-25 of this subchapter.
        19. Section 56.50-70 is amended by revising paragraph (j) to read 
    as follows:
    
    
    Sec. 56.50-70  Gasoline fuel systems.
    
    * * * * *
        (j) Fuel pumps. Each fuel pump must be equipped with controls as 
    required by Sec. 58.01-25 of this subchapter.
        20. Section 56.50-80 is amended by revising its heading and 
    paragraph (h) to read as follows:
    
    
    Sec. 56.50-80  Lubricating-oil systems.
    
    * * * * *
        (h) Sight-flow glasses may be used in lubricating-oil systems 
    provided it has been demonstrated, to the satisfaction of the 
    Commanding Officer, Marine Safety Center, that they can withstand 
    exposure to a flame at a temperature of 927 deg.C (1700 deg.F) for one 
    hour, without failure or appreciable leakage.
    * * * * *
        21. Section 56.50-85 is amended by removing paragraphs (a)(7) (iii) 
    and (iv), by redesignating paragraph (a)(7)(v) as (a)(7)(iii), and by 
    revising the heading and paragraph (a)(7)(ii), newly redesignated 
    paragraph (a)(7)(iii), and paragraph (a)(11) to read as follows:
    
    
    Sec. 56.50-85  Tank-vent piping.
    
        (a) * * *
        (7) * * *
    * * * * *
        (ii) A hinged closure normally open on the outlet of the return 
    bend, which must close automatically by the force of a submerging wave; 
    or
        (iii) Another suitable device acceptable to the Commanding Officer, 
    Marine Safety Center.
    * * * * *
        (11)(i) If a tank may be filled by a pressure head exceeding that 
    for which the tank is designed, the aggregate cross-sectional area of 
    the vents in each tank must be not less than the cross-sectional area 
    of the filling line unless the tank is protected by overflows, in which 
    case the aggregate cross-sectional area of the overflows must be not 
    less than the cross-sectional area of the filling line.
        (ii) Provision must be made to guard against liquids rising in the 
    venting system to a height that would exceed the design head of a cargo 
    tank or fuel-oil tank. It may be made by high-level alarms or overflow-
    control systems or other, equivalent means, together with gauging 
    devices and procedures for filling cargo tanks.
    * * * * *
        22. Section 56.50-90 is amended by revising paragraph (a), 
    redesignating existing paragraphs (c) and (d) as paragraphs (e) and 
    (f), and adding paragraphs (c) and (d) to read as follows:
    
    
    Sec. 56.50-90  Sounding devices.
    
        (a) Each tank must be provided with a suitable means of determining 
    liquid level. Except for a main cargo tank on a tank vessel, each 
    integral hull tank and compartment, unless at all times accessible 
    while the vessel is operating, must be fitted with a sounding pipe.
    * * * * *
        (c) Except as allowed by this paragraph, on each vessel constructed 
    on or after June 9, 1995, no sounding pipe used in a fuel-oil tank may 
    terminate in any space where the risk of ignition of spillage from the 
    pipe might arise. None may terminate in a space for passengers or crew. 
    When practicable, none may terminate in a machinery space. When the 
    Commanding Officer, Marine Safety Center, determines it impracticable 
    to avoid terminating a pipe in a machinery space, a sounding pipe may 
    terminate in a machinery space if all the following requirements are 
    met:
        (1) In addition to the sounding pipe, the fuel-oil tank has an oil-
    level gauge complying with paragraph (d) of this section.
        (2) The pipe terminates in a place remote from ignition hazards 
    unless precautions are taken such as fitting an effective screen 
    (shield) to prevent the fuel oil, in case of spillage through the end 
    of the pipe, from coming into contact with a source of ignition.
        (3) The end of the pipe is fitted with a self-closing blanking 
    device and a small-diameter, self-closing control cock located below 
    the blanking device for the purpose of ascertaining before the blanking 
    device is opened that no fuel [[Page 24775]] oil is present. Provision 
    must be made to ensure that no spillage of fuel oil through the control 
    cock involves an ignition hazard.
        (d) On each vessel constructed on or after June 9, 1995, other oil-
    level gauges may be used instead of sounding pipes if all the following 
    requirements are met:
        (1) In a passenger vessel, no such gauge may require penetration 
    below the top of the tank, and neither the failure of a gauge nor an 
    overfilling of the tank may permit release of fuel into the space.
        (2) In a cargo vessel, neither the failure of such a gauge nor an 
    overfilling of the tank may permit release of fuel into the space. The 
    use of cylindrical gauge-glasses is prohibited. The use of oil-level 
    gauges with flat glasses and self-closing valves between the gauges and 
    fuel tanks is acceptable.
    * * * * *
        23. Section 56.50-105 is amended by revising its heading and 
    paragraphs (a)(5) and (b)(5) to read as follows:
    
    
    Sec. 56.50-105  Low-temperature piping.
    
        (a) * * *
        (5) Other requirements. All other requirements of this part for 
    Class I piping apply to Class I-L piping. Pressure testing must comply 
    with subpart 56.97 of this part, and nondestructive testing of 
    circumferentially welded joints must comply with Sec. 56.95-10. 
    Seamless tubular products must be used except that, when the service 
    pressure does not exceed 1724 KPa (250 psi), the Commanding Officer, 
    Marine Safety Center, may give special consideration to appropriate 
    grades of piping and tubing that are welded without the addition of 
    filler metal in the root pass. Each production procedure and quality-
    control program for welded products must be acceptable to the Officer 
    in Charge, Marine Inspection.
        (b) * * *
        (5) Pressure testing must comply with Subpart 56.97, and 
    nondestructive testing of welded joints must comply with Sec. 56.95-10.
    * * * * *
        24. Section 56.60-25 is amended by revising paragraphs (a)(3) and 
    (b)(1) and by adding paragraph (a)(11) to read as follows:
    
    
    Sec. 56.60-25  Nonmetallic materials.
    
        (a) * * *
        (3) No use of plastic piping within a concealed space in an 
    accommodation or service area is permitted unless--
        (i) Each trunk or duct containing such piping is completely 
    surrounded by ``A'' class divisions; or
        (ii) An approved smoke-detection system is fitted in the concealed 
    space, and each penetration of a bulkhead or deck, and each 
    installation of a draft stop, is made in accordance with paragraph 
    (a)(2) of this section to maintain the integrity of fire divisions.
    * * * * *
        (11) Plastic piping intended for an accommodation area, a service 
    area, or a control station must comply with the standard for the spread 
    of flame or smoke established by Commandant (G-MTH).
        (b) * * *
        (1) Vital machinery served by plastic piping must be duplicated by 
    equivalent machinery served entirely by conventional metallic piping 
    unless allowed otherwise by this section. When such machinery is in 
    separate watertight compartments, or is located or insulated so that 
    damage to both by a single localized fire is unlikely, both may be 
    fitted with plastic piping. (The Marine Inspector will make the final 
    determination as to the adequacy of the separation between duplicate 
    machinery installed in the same watertight compartment.) In no case may 
    failure of plastic piping on one set of machinery affect the operation 
    of the other machinery. Alternatively, a single set of machinery may be 
    installed with parallel, but independent, piping systems, one of 
    plastic and the other of metallic materials. Where metallic piping is 
    required to duplicate or parallel plastic piping, failure of the 
    plastic piping must not interfere with the proper operation of the 
    metallic piping or of the machinery it serves.
    * * * * *
    
    PART 58--MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS
    
        25. The authority citation for part 58 is revised to read as 
    follows:
    
        Authority: 43 U.S.C. 1333; 46 U.S.C. 2103, 3306, 3703; E.O. 
    12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; 49 CFR 1.46.
    
        26. Section 58.01-10 is revised to read as follows:
    
    
    Sec. 58.01-10  Fuel oil.
    
        (a) The following limits apply to the use of oil as fuel:
        (1) Except as otherwise permitted by this section, no fuel oil with 
    a flashpoint of less than 60 deg.C (140 deg.F) may be used.
        (2) Except as otherwise permitted by Sec. 58.50-1(b), fuel oil with 
    a flashpoint of not less than 43 deg.C (110 deg.F) may be used in 
    emergency generators.
        (3) Subject to such additional precautions as the Commanding 
    Officer, Marine Safety Center, considers necessary, and provided that 
    the ambient temperature of the space in which such fuel oil is stored 
    or used does not rise to within 10 deg.C (50 deg.F) below the 
    flashpoint of the fuel oil, fuel oil having a flashpoint of less than 
    60 deg.C (140 deg.F) but not less than 43 deg.C (110 deg.F) may be used 
    in general.
        (4) In a cargo vessel, fuel having a lower flashpoint than 
    otherwise specified in this section--for example, crude oil--may be 
    used provided that such fuel is not stored in any machinery space and 
    that the Commanding Officer, Marine Safety Center, approves the 
    complete installation.
        (b) The flashpoint of oil must be determined by the Pensky-Martens 
    Closed Tester, ASTM-D93-80.
    
    
    Sec. 58.01-15  [Removed]
    
        27. Section 58.01-15 is removed.
        28. Section 58.01-25 is revised to read as follows:
    
    
    Sec. 58.01-25  Means of stopping machinery.
    
        Machinery driving forced-draft and induced-draft fans, fuel-oil 
    transfer pumps, fuel-oil unit and service pumps, and similar fuel-oil 
    pumps must be fitted with remote controls from a readily accessible 
    position outside the space concerned so that the fans or pumps may be 
    stopped in case of fire in the compartment in which they are located. 
    The controls must be suitably protected against accidental operation 
    and against tampering and must be suitably marked.
        29. Sections 58.01-40, 58.01-45, 58.01-50, and 58.01-55 are added 
    to read as follows:
    
    
    Sec. 58.01-40  Machinery, angles of inclination.
    
        (a) Propulsion machinery and all auxiliary machinery essential to 
    the propulsion and safety of the vessel must be designed to operate 
    when the vessel is upright, when the vessel is inclined under static 
    conditions at any angle of list up to and including 15 deg., and when 
    the vessel is inclined under dynamic conditions (rolling) at any angle 
    of list up to and including 22.5 deg. and, simultaneously, at any angle 
    of trim (pitching) up to and including 7.5 deg. by bow or stern.
        (b) Deviations from these angles of inclination may be permitted by 
    the Commanding Officer, Marine Safety Center, considering the type, 
    size, and service of the vessel.
    
    
    Sec. 58.01-45  Machinery space, ventilation.
    
        Each machinery space must be ventilated to ensure that, when 
    machinery or boilers are operating at full power in all weather 
    including heavy weather, an adequate supply of air is maintained for 
    the operation of the [[Page 24776]] machinery and for the safety, 
    efficiency, and comfort of the crew.
    
    
    Sec. 58.01-50  Machinery space, noise.
    
        (a) Each machinery space must be designed to minimize the exposure 
    of personnel to noise in accordance with IMO Assembly Resolution 
    A.468(XII), Code on Noise Levels on Board Ships, 1981. No person may 
    encounter a 24-hour effective noise level greater than 82 dB(A) when 
    noise is measured using a sound-level meter and an A-weighting filter.
        (b) Except as allowed by paragraph (c) of this section, no 
    machinery space may exceed the following noise levels:
    
    (1) Machinery control room--75 dB(A)
    (2) Manned machinery space--90 dB(A)
    (3) Unmanned machinery space--110 dB(A)
    (4) Periodically unattended machinery space--110 dB(A)
    (5) Workshop--85 dB(A)
    (6) Any other work space around machinery--90 dB(A)
    
        (c) If adding a source of noise would cause a machinery space to 
    exceed the noise level permitted by paragraph (b) of this section, the 
    new source must be suitably insulated or isolated so that the space 
    does not exceed that noise level. If the space is manned, a refuge from 
    noise must be provided within the space.
        (d) Ear protection must be provided for any person entering any 
    space with a noise level greater than 85 dB(A).
        (e) Each entrance to a machinery space with a noise level greater 
    than 85 dB(A) must have a warning sign stating that each person 
    entering the space must wear ear protection.
    
    
    Sec. 58.01-55  Tanks for flammable and combustible oil.
    
        (a) For the purposes of this section, a machinery space of category 
    A is a space that contains any of the following:
        (1) Internal-combustion machinery used for main propulsion.
        (2) Internal-combustion machinery used for other than main 
    propulsion, whose power output is equal to or greater than 500 HP (375 
    kw).
        (3) Any oil-fired boiler.
        (4) Any equipment used to prepare fuel oil for delivery to an oil-
    fired boiler, or equipment used to prepare heated oil for delivery to 
    an internal-combustion engine, including any oil-pressure pumps, 
    filters, and heaters dealing with oil pressures above 26 psi.
        (b) As far as practicable, each fuel-oil tank must be part of the 
    vessel's structure and be located outside a machinery space of category 
    A.
        (c) If a fuel-oil tank, other than a double-bottom tank, must be 
    located adjacent to or within a machinery space of category A--
        (1) At least one of its vertical sides must be contiguous to the 
    boundary of the machinery space;
        (2) The tank must have a common boundary with the double-bottom 
    tanks; and
        (3) The area of the tank boundary common with the machinery spaces 
    must be kept as small as practicable.
        (d) If a fuel-oil tank must be located within a machinery space of 
    category A, it must not contain fuel oil with a flashpoint of less than 
    60 deg.C (140 deg.F).
        (e) In general, no freestanding fuel-oil tank is permitted in any 
    machinery space of Category A on a passenger vessel. A freestanding 
    fuel-oil tank is permitted in other spaces only if authorized by the 
    Commanding Officer, Marine Safety Center. If so authorized, each 
    freestanding fuel-oil tank must--
        (i) Comply with Subpart 58.50 of this subchapter; and
        (ii) Be placed in an oil-tight spill tray with a drain pipe leading 
    to a spill-oil tank.
        (f) No fuel-oil tank may be located where spillage or leakage from 
    it can constitute a hazard by falling on heated surfaces. The design 
    must also prevent any oil that may escape under pressure from any pump, 
    filter, or heater from coming into contact with heated surfaces.
    
    
    Sec. 58.03-1  [Amended]
    
        30. Section 58.03-1(b) is amended by adding, in alphabetical order, 
    two publications of the International Maritime Organization to read as 
    follows:
    * * * * *
        (b) * * *
    
    International Maritime Organization (IMO) 4 Albert Embankment, 
    London SE1 7SR, England
    
    A.467(XII), Guidelines for Acceptance of Non-Duplicated Rudder 
    Actuators for Tankers, Chemical Tankers and Gas Carriers of 10,000 
    Tons Gross Tonnage and Above But Less Than 100,000 Tonnes 
    Deadweight, 1981--58.25-60
    A.468(XII), Code on Noise Levels on Board Ships, 1981--58.01-50
    * * * * *
    
    Subpart 58.05--Main Propulsion Machinery
    
        31-32. Subpart 58.05 is amended by revising paragraph (a) of 
    Sec. 58.05-1 and adding Sec. 58.05-10 to read as follows:
    
    
    Sec. 58.05-1  Material, design, and construction.
    
        (a) The material, design, construction, workmanship, and 
    arrangement of main propulsion machinery and of each auxiliary, 
    directly connected to the engine and supplied as such, must be at least 
    equivalent to the standards established by the American Bureau of 
    Shipping or other recognized classification society, except as 
    otherwise provided by this subchapter.
    * * * * *
    
    
    Sec. 58.05-10  Automatic shut-off.
    
        Main propulsion machinery must be provided with automatic shut-off 
    controls in accordance with part 62 of this subchapter. These controls 
    must shut down main propulsion machinery in case of a failure, such as 
    failure of the lubricating-oil supply, that could lead rapidly to 
    complete breakdown, serious damage, or explosion.
    
    
    Sec. 58.10-15  [Amended]
    
        33. Section 58.10-15 is amended by removing paragraph (e) and by 
    redesignating paragraphs (f), (g), (h), (i), and (j), respectively, as 
    (e), (f), (g), (h), and (i).
        34. Subpart 58.25 is revised to read as follows:
    
    Subpart 58.25--Steering Gear
    
    Sec.
    58.25-1  Applicability.
    58.25-5  General.
    58.25-10  Main and auxiliary steering gear.
    58.25-15  Voice communications.
    58.25-20  Piping for steering gear.
    58.25-25  Indicating and alarm systems.
    58.25-30  Automatic restart.
    58.25-35  Helm arrangements.
    58.25-40  Arrangement of the steering-gear compartment.
    58.25-45  Buffers.
    58.25-50  Rudder stops.
    58.25-55  Overcurrent protection for steering-gear systems.
    58.25-60  Non-duplicated hydraulic rudder actuators.
    58.25-65  Feeder circuits.
    58.25-70  Steering-gear control systems.
    58.25-75  Materials.
    58.25-80  Automatic pilots and ancillary steering gear.
    58.25-85  Special requirements for tank vessels.
    
    Subpart 58.25--Steering Gear
    
    
    Sec. 58.25-1  Applicability.
    
        (a) Except as specified otherwise, this subpart applies to--
        (1) Each vessel or installation of steering gear contracted for on 
    or after June 9, 1995; and
        (2) Each vessel on an international voyage with an installation of 
    steering gear contracted for on or after September 1, 1984.
        (b) Each vessel not on an international voyage with an installation 
    of steering gear contracted for before June 9, 1995, and each vessel on 
    an international voyage with such an installation 
    [[Page 24777]] contracted for before September 1, 1984, may meet either 
    the requirements of this subpart or those in effect on the date of the 
    installation.
    
    
    Sec. 58.25-5  General.
    
        (a) Definitions.
        Ancillary steering equipment means steering equipment, other than 
    the required control systems and power actuating systems, that either 
    is not required, such as automatic pilot or non-followup control from 
    the pilothouse, or is necessary to perform a specific required 
    function, such as the automatic detection and isolation of a defective 
    section of a tanker's hydraulic steering gear.
        Auxiliary steering gear means the equipment, other than any part of 
    the main steering gear, necessary to steer the vessel in case of 
    failure of the main steering gear, not including a tiller, quadrant, or 
    other component serving the same purpose. Control system means the 
    equipment by which orders for rudder movement are transmitted from the 
    pilothouse to the steering-gear power units. A control system for 
    steering gear includes, but is not limited to, one or more--
        (1) Transmitters;
        (2) Receivers;
        (3) Feedback devices;
        (4) Hydraulic servo-control pumps, with associated motors and motor 
    controllers;
        (5) Differential units, hunting gear, and similar devices;
        (6) All gearing, piping, shafting, cables, circuitry, and ancillary 
    devices for controlling the output of power units; and
        (7) Means of bringing steering-gear power units into operation.
        Fast-acting valve, as used in this subpart, means a ball, plug, 
    spool, or similar valve with a handle connected for quick manual 
    operation.
        Followup control means closed-loop (feedback) control that relates 
    the position of the helm to a specific rudder angle by transmitting the 
    helm-angle order to the power actuating system and, by means of 
    feedback, automatically stopping the rudder when the angle selected by 
    the helm is reached.
        Main steering gear means the machinery, including power actuating 
    systems, and the means of applying torque to the rudder stock, such as 
    a tiller or quadrant, necessary for moving the rudder to steer the 
    vessel in normal service.
        Maximum ahead service speed means the greatest speed that a vessel 
    is designed to maintain in service at sea at the deepest loadline 
    draft.
        Maximum astern speed means the speed that it is estimated the 
    vessel can attain at the maximum designed power astern at the deepest 
    loadline draft.
        Power actuating system means the hydraulic equipment for applying 
    torque to the rudder stock. It includes, but is not limited to--
        (1) Rudder actuators;
        (2) Steering-gear power units; and
        (3) Pipes, valves, fittings, linkages, and cables for transmitting 
    power from the power unit or units to the rudder actuator or actuators.
        Speedily regained, as used in this subpart, refers to the time it 
    takes one qualified crewmember, after arriving in the steering-gear 
    compartment, and without the use of tools, to respond to a failure of 
    the steering gear and take the necessary corrective action.
        Steering capability means steering equivalent to that required of 
    auxiliary steering gear by Sec. 58.25-10(c)(2).
        Steering gear means the machinery, including power actuating 
    systems, control systems, and ancillary equipment, necessary for moving 
    the rudder to steer the vessel.
        Steering-gear power unit means:
        (1) In the case of electric steering gear, an electric motor and 
    its associated electrical equipment, including motor controller, 
    disconnect switch, and feeder circuit.
        (2) In the case of an electro-hydraulic steering gear, an electric 
    motor, connected pump, and associated electrical equipment such as the 
    motor controller, disconnect switch, and feeder circuit.
        (3) In the case of hydraulic steering gear, the pump and its prime 
    mover.
        Tank vessel, as used in this subpart, means a self-propelled 
    vessel, including a chemical tanker or a gas carrier, defined either as 
    a tanker by 46 U.S.C. 2101(38) or as a tank vessel by 46 U.S.C. 
    2101(39).
        (b) Unless it otherwise complies with this subpart, each self-
    propelled vessel must be provided with a main steering gear and an 
    auxiliary steering gear. These gear must be arranged so that--
        (1) The failure of one will not render the other inoperative; and
        (2) Transfer from the main to the auxiliary can be effected 
    quickly.
        (c) Each substantial replacement of steering-gear components or 
    reconfiguration of steering-gear arrangements on an existing vessel 
    must comply with the requirements of this subpart for new installations 
    to the satisfaction of the cognizant Officer in Charge, Marine 
    Inspection.
        (d) Each non-pressure-containing steering-gear component and each 
    rudder stock must be of sound and reliable construction, meet the 
    minimum material requirements of Sec. 58.25-75, and be designed to 
    standards at least equal to those established by the American Bureau of 
    Shipping or other recognized classification society.
        (e) The suitability of any essential steering-gear component not 
    duplicated must be specifically approved by the Commanding Officer, 
    Marine Safety Center. Where a steering-gear component is shared by--
        (1) A control system (e.g., a control-system transfer switch 
    located in the steering-gear compartment);
        (2) The main and auxiliary steering gear (e.g., an isolation 
    valve); or
        (3) A power actuating system and its control system (e.g., a 
    directional control valve)--the requirements for both systems apply, to 
    provide the safest and most reliable arrangement.
        (f) Steering gear must be separate and independent of all other 
    shipboard systems, except--
        (1) Electrical switchboards from which they are powered;
        (2) Automatic pilots and similar navigational equipment; and
        (3) Propulsion machinery for an integrated system of propulsion and 
    steering.
        (g) Except on a vessel with an integrated system of propulsion and 
    steering, no thruster may count as part of a vessel's required steering 
    capability.
        (h) Except for a tank vessel subject to Sec. 58.25-85(e), each 
    oceangoing vessel required to have power-operated steering gear must be 
    provided with arrangements for steadying the rudder both in an 
    emergency and during a shift from one steering gear to another. On 
    hydraulic steering gear, a suitable arrangement of stop valves in the 
    main piping is an acceptable means of steadying the rudder.
        (i) General arrangement plans for the main and auxiliary steering 
    gear and their piping must be submitted for approval in accordance with 
    subpart 50.20 of this subchapter.
    
    
    Sec. 58.25-10  Main and auxiliary steering gear.
    
        (a) Power-operated main and auxiliary steering gear must be 
    separate systems that are independent throughout their length. Other 
    systems and arrangements of steering gear will be acceptable if the 
    Commanding Officer, Marine Safety Center, determines that they comply 
    with, or exceed the requirements of, this subpart.
        (b) The main steering gear and rudder stock must be--
        (1) Of adequate strength for and capable of steering the vessel at 
    [[Page 24778]] maximum ahead service speed, which must be demonstrated 
    to the satisfaction of the cognizant Officer in Charge, Marine 
    Inspection;
        (2) Capable of moving the rudder from 35 deg. on either side to 
    35 deg. on the other with the vessel at its deepest loadline draft and 
    running at maximum ahead service speed, and from 35 deg. on either side 
    to 30 deg. on the other in not more than 28 seconds under the same 
    conditions;
        (3) Operated by power when necessary to comply with paragraph 
    (b)(2) of this section or when the diameter of the rudder stock is over 
    12 centimeters (4.7 inches) in way of the tiller, excluding 
    strengthening for navigation in ice; and
        (4) Designed so that they will not be damaged when operating at 
    maximum astern speed; however, this requirement need not be proved by 
    trials at maximum astern speed and maximum rudder angle.
        (c) The auxiliary steering gear must be--
        (1) Of adequate strength for and capable of steering the vessel at 
    navigable speed and of being brought speedily into action in an 
    emergency;
        (2) Capable of moving the rudder from 15 deg. on either side to 
    15 deg. on the other in not more than 60 seconds with the vessel at its 
    deepest loadline draft and running at one-half maximum ahead service 
    speed or 7 knots, whichever is greater; and
        (3) Operated by power when necessary to comply with paragraph 
    (c)(2) of this section or when the diameter of the rudder stock is over 
    23 centimeters (9 inches) in way of the tiller, excluding strengthening 
    for navigation in ice.
        (d) No auxiliary means of steering is required on a double-ended 
    ferryboat with independent main steering gear fitted at each end of the 
    vessel.
        (e) When the main steering gear includes two or more identical 
    power units, no auxiliary steering gear need be fitted, if--
        (1) In a passenger vessel, the main steering gear is capable of 
    moving the rudder as required by paragraph (b)(2) of this section while 
    any one of the power units is not operating;
        (2) In a cargo vessel, the main steering gear is capable of moving 
    the rudder as required by paragraph (b)(2) of this section while all 
    the power units are operating;
        (3) In a vessel with an installation completed on or after 
    September 1, 1984, and on an international voyage, and in any other 
    vessel with an installation completed after June 9, 1995, the main 
    steering gear is arranged so that, after a single failure in its piping 
    system (if hydraulic), or in one of the power units, the defect can be 
    isolated so that steering capability can be maintained or speedily 
    regained in less than ten minutes; or
        (4) In a vessel with an installation completed before September 1, 
    1986, and on an international voyage, with steering gear not complying 
    with paragraph (e)(3) of this section, the installed steering gear has 
    a proved record of reliability and is in good repair.
    
        Note.--The place where isolation valves join the piping system, 
    as by a flange, constitutes a single-failure point. The valve itself 
    need not constitute a single-failure point if it has a double seal 
    to prevent substantial loss of fluid under pressure. Means to purge 
    air that enters the system as a result of the piping failure must be 
    provided, if necessary, so that steering capability can be 
    maintained or speedily regained in less than ten minutes.
    
        (f) In each vessel of 70,000 gross tons or over, the main steering 
    gear must have two or more identical power units complying with 
    paragraph (e) of this section.
    
    
    Sec. 58.25-15  Voice communications.
    
        Each vessel must be provided with a sound-powered telephone system, 
    complying with subpart 113.30 of this chapter, to communicate between 
    the pilothouse and the steering-gear compartment, unless an alternative 
    means of communication between them has been approved by the Commanding 
    Officer, Marine Safety Center.
    
    
    Sec. 58.25-20  Piping for steering gear.
    
        (a) Pressure piping must comply with subpart 58.30 of this part.
        (b) Relief valves must be fitted in any part of a hydraulic system 
    that can be isolated and in which pressure can be generated from the 
    power units or from external forces such as wave action. The valves 
    must be of adequate size, and must be set to limit the maximum pressure 
    to which the system may be exposed, in accordance with Sec. 56.07-10(b) 
    of this subchapter.
        (c) Each hydraulic system must be provided with--
        (1) Arrangements to maintain the cleanliness of the hydraulic 
    fluid, appropriate to the type and design of the hydraulic system; and
        (2) For a vessel on an ocean, coastwise, or Great Lakes voyage, a 
    fixed storage tank having sufficient capacity to recharge at least one 
    power actuating system including the reservoir. The storage tank must 
    be permanently connected by piping so that the hydraulic system can be 
    readily recharged from within the steering-gear compartment and must be 
    fitted with a device to indicate liquid level that complies with 
    Sec. 56.50-90 of this subchapter.
        (d) Neither a split flange nor a flareless fitting of the grip or 
    bite type, addressed by Sec. 56.30-25 of this subchapter, may be used 
    in hydraulic piping for steering gear.
    
    
    Sec. 58.25-25  Indicating and alarm systems.
    
        (a) Indication of the rudder angle must be provided both at the 
    main steering station in the pilothouse and in the steering-gear 
    compartment. The rudder-angle indicator must be independent of control 
    systems for steering gear.
        (b) Each electric-type rudder-angle indicator must comply with 
    Sec. 113.40-10 of this chapter and, in accordance with Sec. 112.15-5(h) 
    of this chapter, draw its power from the source of emergency power.
        (c) On each vessel of 1,600 gross tons or over, a steering-failure 
    alarm must be provided in the pilothouse in accordance with 
    Secs. 113.43-3 and 113.43-5 of this chapter.
        (d) An audible and a visible alarm must activate in the pilothouse 
    upon--
        (1) Failure of the electric power to the control system of any 
    steering gear;
        (2) Failure of that power to the power unit of any steering gear; 
    or
        (3) Occurrence of a low oil level in any oil reservoir of a 
    hydraulic, power-operated steering-gear system.
        (e) An audible and a visible alarm must activate in the machinery 
    space upon--
        (1) Failure of any phase of a three-phase power supply;
        (2) Overload of any motor described by Sec. 58.25-55(c); or
        (3) Occurrence of a low oil level in any oil reservoir of a 
    hydraulic, power-operated steering-gear system.
    
        Note.--See Sec. 62.50-30(f) of this subchapter regarding 
    extension of alarms to the navigating bridge on vessels with 
    periodically unattended machinery spaces.
    
        (f) Each power motor for the main and auxiliary steering gear must 
    have a ``motor running'' indicator light in the pilothouse, and in the 
    machinery space, that activates when the motor is energized.
    
    
    Sec. 58.25-30  Automatic restart.
    
        Each control system for main and auxiliary steering gear and each 
    power actuating system must restart automatically when electrical power 
    is restored after it has failed.
    
    
    Sec. 58.25-35  Helm arrangements.
    
        (a) The arrangement of each steering station, other than in the 
    steering-gear [[Page 24779]] compartment, must be such that the 
    helmsman is abaft the wheel. The rim of the wheel must be plainly 
    marked with arrows and lettering for right and left rudder, or a 
    suitable notice indicating these directions must be posted directly in 
    the helmsman's line of sight.
        (b) Each steering wheel must turn clockwise for ``right rudder'' 
    and counterclockwise for ``left rudder.'' When the vessel is running 
    ahead, after clockwise movement of the wheel the vessel's heading must 
    change to the right.
        (c) If a lever-type control is provided, it must be installed and 
    marked so that its movement clearly indicates both the direction of the 
    rudder's movement and, if followup control is also provided, the amount 
    of the rudder's movement.
        (d) Markings in the pilothouse must not interfere with the 
    helmsman's vision, but must be clearly visible at night.
    
        Note.--See Sec. 113.40-10 of this chapter for the arrangement of 
    rudder-angle indicators at steering stations.
    
    
    Sec. 58.25-40  Arrangement of the steering-gear compartment.
    
        (a) The steering-gear compartment must--
        (1) Be readily accessible and, as far as practicable, separated 
    from any machinery space;
        (2) Ensure working access to machinery and controls in the 
    compartment; and
        (3) Include handrails and either gratings or other non-slip 
    surfaces to ensure a safe working environment if hydraulic fluid leaks.
    
        Note.--Where practicable, all steering gear should be located in 
    the steering-gear compartment.
    
        (b) [Reserved]
    
    
    Sec. 58.25-45  Buffers.
    
        For each vessel on an ocean, coastwise, or Great Lakes voyage, 
    steering gear other than hydraulic must be designed with suitable 
    buffering arrangements to relieve the gear from shocks to the rudder.
    
    
    Sec. 58.25-50  Rudder stops.
    
        (a) Power-operated steering gear must have arrangements for cutting 
    off power to the gear before the rudder reaches the stops. These 
    arrangements must be synchronized with the rudder stock or with the 
    gear itself rather than be within the control system for the steering 
    gear, and must work by limit switches that interrupt output of the 
    control system or by other means acceptable to the Commanding Officer, 
    Marine Safety Center.
        (b) Strong and effective structural rudder stops must be fitted; 
    except that, where adequate positive stops are provided within the 
    steering gear, such structural stops need not be fitted.
    
    
    Sec. 58.25-55  Overcurrent protection for steering-gear systems.
    
        (a) Each feeder circuit for steering must be protected by a circuit 
    breaker on the switchboard that supplies it and must have an 
    instantaneous trip set at a current of at least--
        (1) 300% and not more than 375% of the rated full-load current of 
    one steering-gear motor for a direct-current motor; or
        (2) 175% and not more than 200% of the locked-rotor current of one 
    steering-gear motor for an alternating-current motor.
        (b) No feeder circuit for steering may have any overcurrent 
    protection, except that required by paragraph (a) of this section.
        (c) Neither a main or an auxiliary steering-gear motor, nor a motor 
    for a steering-gear control system, may be protected by an overload 
    protective device. The motor must have a device that activates an 
    audible and a visible alarm at the main machinery-control station if 
    there is an overload that would cause overheating of the motor.
        (d) No control circuit of a motor controller, steering-gear control 
    system, or indicating or alarm system may have overcurrent protection 
    except short-circuit protection that is instantaneous and rated at 400% 
    to 500% of--
        (1) The current-carrying capacity of the conductor; or
        (2) The normal load of the system.
        (e) The short-circuit protective device for each steering-gear 
    control system must be in the steering-gear compartment and in the 
    control circuit immediately following the disconnect switch for the 
    system.
        (f) When, in a vessel of less than 1,600 gross tons, an auxiliary 
    steering gear, which Sec. 58.25-10(c)(3) requires to be operated by 
    power, is not operated by electric power or is operated by an electric 
    motor primarily intended for other service, the main steering gear may 
    be fed by one circuit from the main switchboard. When such an electric 
    motor is arranged to operate an auxiliary steering gear, neither 
    Sec. 58.25-25(e) nor paragraphs (a) through (c) of this section need be 
    complied with if both the overcurrent protection and compliance with 
    Secs. 58.25-25(d), 58.25-30, and 58.25-70 (j) and (k) satisfy the 
    Commanding Officer, Marine Safety Center.
    
    
    Sec. 58.25-60  Non-duplicated hydraulic rudder actuators.
    
        Non-duplicated hydraulic rudder actuators may be installed in the 
    steering-gear control systems on each vessel of less than 100,000 
    deadweight tons. These actuators must meet IMO Assembly Resolution 
    A.467(XII), Guidelines for Acceptance of Non-Duplicated Rudder 
    Actuators for Tankers, Chemical Tankers, and Gas Carriers of 10,000 
    Tons Gross Tonnage and Above But Less Than 100,000 Tonnes Deadweight, 
    1981, and be acceptable to the Commanding Officer, Marine Safety 
    Center. Also, the piping for the main gear must comply with Sec. 58.25-
    10(e)(3).
    
    
    Sec. 58.25-65  Feeder circuits.
    
        (a) Each vessel with one or more electric-driven steering-gear 
    power units must have at least two feeder circuits, which must be 
    separated as widely as practicable. One or more of these circuits must 
    be supplied from the vessel's service switchboard. On a vessel where 
    the rudder stock is over 23 centimeters (9 inches) in diameter in way 
    of the tiller, excluding strengthening for navigation in ice, and where 
    a final source of emergency power is required by Sec. 112.05-5(a) of 
    this chapter, one or more of these circuits must be supplied from the 
    emergency switchboard, or from an alternative source of power that--
        (1) Is available automatically within 45 seconds of loss of power 
    from the vessel's service switchboard;
        (2) Comes from an independent source of power in the steering-gear 
    compartment;
        (3) Is used for no other purpose; and
        (4) Has a capacity for one half-hour of continuous operation, to 
    move the rudder from 15 deg. on either side to 15 deg. on the other in 
    not more than 60 seconds with the vessel at its deepest loadline draft 
    and running at one-half maximum ahead service speed or 7 knots, 
    whichever is greater.
        (b) Each vessel that has a steering gear with multiple electric-
    driven power units must be arranged so that each power unit is supplied 
    by a separate feeder.
        (c) Each feeder circuit must have a disconnect switch in the 
    steering-gear compartment.
        (d) Each feeder circuit must have a current-carrying capacity of--
        (1) 125% of the rated full-load current rating of the electric 
    steering-gear motor or power unit; and
        (2) 100% of the normal current of one steering-gear control system 
    including all associated motors. [[Page 24780]] 
    
    
    Sec. 58.25-70  Steering-gear control systems.
    
        (a) Each power-driven steering-gear system must be provided with at 
    least one steering-gear control system.
        (b) The main steering gear must be operable from the pilothouse by 
    mechanical, hydraulic, electrical, or other means acceptable to the 
    Commanding Officer, Marine Safety Center. This gear and its components 
    must give full followup control of the rudder. Supplementary steering-
    gear control not giving full followup may also be provided from the 
    pilothouse.
        (c) Each steering-gear control system must have in the pilothouse a 
    switch arranged so that one operation of the switch's lever 
    automatically supplies power to a complete system and its associated 
    power unit or units. This switch must be--
        (1) Operated by one lever;
        (2) Arranged so that not more than one control system and its 
    associated power unit or units can be energized from the pilothouse at 
    any one time;
        (3) Arranged so that the lever passes through ``off'' during 
    transfer of control from one control system to another; and
        (4) Arranged so that the switches for each control system are in 
    separate enclosures or are separated by fire-resistant barriers.
        (d) Each steering-gear control system must receive its power from--
        (1) The feeder circuit supplying power to its steering-gear power 
    unit or units in the steering-gear compartment; or
        (2) A direct connection to the busbars supplying the circuit for 
    its steering-gear power unit or units from a point on the switchboard 
    adjacent to that supply.
        (e) Each steering-gear control system must have a switch that--
        (1) Is in the steering-gear compartment; and
        (2) Disconnects the system from its power source and from the 
    steering gear that the system serves.
        (f) Each motor controller for a steering gear must be in the 
    steering-gear compartment.
        (g) A means of starting and stopping each motor for a steering gear 
    must be in the steering-gear compartment.
        (h) When the main steering gear is arranged in accordance with 
    Sec. 58.25-10(e), two separate and independent systems for full 
    followup control must be provided in the pilothouse; except that--
        (1) The steering wheel or lever need not be duplicated; and
        (2) If the system consists of a hydraulic telemotor, no second 
    separate and independent system need be provided other than on each 
    tank vessel subject to Sec. 58.25-85.
        (i) When only the main steering gear is power-driven, two separate 
    and independent systems for full followup control must be provided in 
    the pilothouse; except that the steering wheel or lever need not be 
    duplicated.
        (j) When the auxiliary steering gear is power-driven, a control 
    system for the auxiliary steering gear must be provided in the 
    pilothouse that is separate and independent from the control system for 
    the main steering gear; except that the steering wheel or lever need 
    not be duplicated.
        (k) On a vessel of 500 gross tons or above, each main steering gear 
    and auxiliary steering gear must be arranged so that its power unit or 
    units are operable by controls from the steering-gear compartment. 
    These controls must not be rendered inoperable by failure of the 
    controls in the pilothouse.
    
    
    Sec. 58.25-75  Materials.
    
        (a) Materials used for the mechanical or hydraulic transmission of 
    power to the rudder stock must have an elongation of at least 15% in 5 
    centimeters (2 inches); otherwise, components used for this purpose 
    must be shock-tested in accordance with subpart 58.30 of this part.
        (b) No materials with low melting-points, including such materials 
    as aluminum and nonmetallic seals, may be used in control systems for 
    steering gear or in power actuating systems unless--
        (1) The materials are within a compartment having little or no risk 
    of fire;
        (2) Because of redundancy in the system, damage by fire to any 
    component would not prevent immediate restoration of steering 
    capability; or
        (3) The materials are within a steering-gear power actuating 
    system.
    
    
    Sec. 58.25-80  Automatic pilots and ancillary steering gear.
    
        (a) Automatic pilots and ancillary steering gear, and steering-gear 
    control systems, must be arranged to allow immediate resumption of 
    manual operation of the steering-gear control system required in the 
    pilothouse. A switch must be provided, at the primary steering position 
    in the pilothouse, to completely disconnect the automatic equipment 
    from the steering-gear controls.
        (b) Automatic pilots and ancillary steering gear must be arranged 
    so that no single failure affects proper operation and independence of 
    the main or auxiliary steering gear, required controls, rudder-angle 
    indicators, or steering-failure alarm.
    
    
    Sec. 58.25-85  Special requirements for tank vessels.
    
        (a) Each tank vessel must meet the applicable requirements of 
    Secs. 58.25-1 through 58.25-80.
        (b) On each tank vessel of 10,000 gross tons or over, the main 
    steering gear must comprise two or more identical power units that 
    comply with Sec. 58.25-10(e)(2).
        (c) Each tank vessel of 10,000 gross tons or over constructed on or 
    after September 1, 1984, must comply with the following:
        (1) The main steering gear must be arranged so that, in case of 
    loss of steering capability due to a single failure in any part of the 
    power actuating system of the main steering gear, excluding seizure of 
    a rudder actuator or failure of the tiller, quadrant, or components 
    serving the same purpose, steering capability can be regained not more 
    than 45 seconds after the loss of one power actuating system.
        (2) The main steering gear must include either--
        (i) Two separate and independent power actuating systems, complying 
    with Sec. 58.25-10(b)(2); or
        (ii) At least two identical hydraulic-power actuating systems, 
    which, acting simultaneously in normal operation, must comply with 
    Sec. 58.25-10(b)(2). (When they must so comply, these systems must be 
    connected. Loss of hydraulic fluid from one system must be capable of 
    being detected, and the defective system automatically isolated, so the 
    other system or systems remain fully operational.)
        (3) Steering gear other than hydraulic must meet equivalent 
    standards to the satisfaction of the Commanding Officer, Marine Safety 
    Center.
        (d) On each tank vessel of 10,000 gross tons or over, but less than 
    100,000 deadweight tons, the main steering gear need not comply with 
    paragraph (c) of this section if the rudder actuator or actuators 
    installed are non-duplicated hydraulic and if--
        (1) The actuators comply with Sec. 58.25-60; and
        (2) In case of loss of steering capability due to a single failure 
    either of any part of the piping systems or in one of the power units, 
    steering capability can be regained in not more than 45 seconds.
        (e) On each tank vessel of less than 70,000 deadweight tons, 
    constructed before, and with a steering-gear installation before, 
    September 1, 1986, and on an international voyage, the steering gear 
    not complying with paragraph (c) (1), (2), or (3) of this section, as 
    applicable, may continue in service if the steering gear has a proved 
    [[Page 24781]] record of reliability and is in good repair.
        (f) Each tank vessel of 10,000 gross tons or over, constructed 
    before, and with a steering-gear installation before, September 1, 
    1984, must--
        (1) Meet the applicable requirements in Secs. 58.25-15, 58.25-
    20(c), 58.25-25 (a), (d), and (e), and 58.25-70 (e), (h), (i), and (j);
        (2) Ensure working access to machinery and controls in the 
    steering-gear compartment (which must include handrails and either 
    gratings or other non-slip surfaces to ensure a safe working 
    environment in case hydraulic fluid leaks);
        (3) Have two separate and independent steering-gear control 
    systems, each of which can be operated from the pilothouse; except that 
    it need not have separate steering wheels or steering levers;
        (4) Arrange each system required by paragraph (f)(3) of this 
    section so that, if the one in operation fails, the other can be 
    operated from the pilothouse immediately; and
        (5) Supply each system required by paragraph (f)(3) of this 
    section, if electric, with power by a circuit that is--
        (i) Used for no other purpose; and either--
        (ii) Connected in the steering-gear compartment to the circuit 
    supplying power to the power unit or units operated by that system; or
        (iii) Connected directly to the busbars supplying the circuit for 
    its steering-gear power unit or units at a point on the switchboard 
    adjacent to that supply.
        (g) Each tank vessel of 40,000 gross tons or over, constructed 
    before, and with a steering-gear installation before, September 1, 
    1984, and on an international voyage, must have the steering gear 
    arranged so that, in case of a single failure of the piping or of one 
    of the power units, either steering capability equivalent to that 
    required of the auxiliary steering gear by Sec. 58.25-10(c)(2) can be 
    maintained or the rudder's movement can be limited so that steering 
    capability can be speedily regained in less than 10 minutes. This 
    arrangement must be achieved by--
        (1) An independent means of restraining the rudder;
        (2) Fast-acting valves that may be manually operated to isolate the 
    actuator or actuators from the external hydraulic piping, together with 
    a means of directly refilling the actuators by a fixed, independent, 
    power-operated pump and piping; or
        (3) An arrangement such that, if hydraulic-power actuating systems 
    are connected, loss of hydraulic fluid from one system must be detected 
    and the defective system isolated either automatically or from within 
    the pilothouse so that the other system remains fully operational.
    
        Note.--The term ``piping or * * * one of the power units'' in 
    paragraph (g) of this section refers to the pressure-containing 
    components in hydraulic or electro-hydraulic steering gear. It does 
    not include rudder actuators or hydraulic-control servo piping and 
    pumps used to stroke the pump or valves of the power unit, unless 
    their failure would result in failure of the unit or of the piping 
    to the actuator.
    
        35. Section 58.30-5 is amended by adding paragraph (d) to read as 
    follows:
    
    
    Sec. 58.30-5  Design requirements.
    
    * * * * *
        (d) Each pneumatic system must minimize the entry of oil into the 
    system and must drain the system of liquids.
    
    PART 61--PERIODIC TESTS AND INSPECTIONS
    
        36. The authority citation for part 61 is revised to read as 
    follows:
    
        Authority: 43 U.S.C. 1333; 46 U.S.C. 2103, 3306, 3703; E.O. 
    12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; 49 CFR 1.46.
    
        37. Section 61.05-10 is amended by revising paragraphs (a) and (b), 
    removing current Table 61.05-10, and adding new Table 61.05-10 after 
    current paragraph (g) to read as follows:
    
    
    Sec. 61.05-10  Boilers in service.
    
        (a) Each boiler, including superheater, reheater, economizer, 
    auxiliary boiler, low-pressure heating boiler, and unfired steam 
    boiler, must be available for examination by the marine inspector at 
    intervals specified by Table 61.05-10, and more often if necessary, to 
    determine that the complete unit is in a safe and satisfactory 
    condition. When a hydrostatic test is required, the marine inspector 
    may examine all accessible parts of the boiler while it is under 
    pressure.
        (b) The owner, master, or person in charge of the vessel shall give 
    ample notice to the cognizant Officer in Charge, Marine Inspection, so 
    that a marine inspector may witness the tests and make the required 
    inspections.
    * * * * *
    
                                  Table 61.05-10.--Inspection Intervals for Boilers123                              
    ----------------------------------------------------------------------------------------------------------------
                                                                 Firetube                      Any                  
                                                                boiler  150     boiler      boiler for  boiler < 150="" psi="" propulsion="" psi="" ----------------------------------------------------------------------------------------------------------------="" hydro="" test:="" passenger="" vessel.....................................="" 2.5="" 2.5="" 1="" 2.5="" other="" vessel.........................................="" 2.5="" 5="" 1="" 5="" fireside="" inspection......................................="" 1="" 2.5="" 1="" 2.5="" waterside="" inspection.....................................="" 1="" 2.5="" 1="" 2.5="" boiler="" safety-valve="" test.................................="" 1="" coi="" 1="" 1="" valves="" inspection........................................="" 5="" 5="" 5="" 5="" studs="" and="" bolts="" inspection...............................="" 10="" 10="" 10="" 10="" mountings="" inspection.....................................="" 10="" 10="" 10="" 10="" steam="" gauge="" test.........................................="" coi="" coi="" coi="" coi="" fusible="" plug="" inspection..................................="" 2.5="" ............="" coi="" 2.5="" ----------------------------------------------------------------------------------------------------------------="" \1\all="" intervals="" are="" in="" years;="" where="" coi="" is="" used,="" the="" intervals="" coincide="" with="" the="" applicable="" vessel's="" inspection="" for="" certification.="" \2\where="" the="" 2.5-year="" interval="" is="" indicated:="" two="" tests="" or="" inspections="" must="" occur="" within="" any="" five-year="" period,="" and="" no="" more="" than="" three="" years="" may="" elapse="" between="" any="" test="" or="" inspection="" and="" its="" immediate="" predecessor.="" \3\intervals="" for="" hybrid="" boilers="" are="" the="" same="" as="" for="" firetube="" boilers.="" [[page="" 24782]]="" 38.="" section="" 61.05-15="" is="" amended="" by="" revising="" paragraphs="" (a),="" (b),="" (c)(1),="" (f),="" and="" (g)="" to="" read="" as="" follows:="" sec.="" 61.05-15="" boiler="" mountings="" and="" attachments.="" (a)="" each="" valve="" shall="" be="" opened="" and="" examined="" by="" the="" marine="" inspector="" at="" the="" interval="" specified="" in="" table="" 61.05-10.="" (b)="" each="" stud="" or="" bolt="" for="" each="" boiler="" mounting="" that="" paragraph="" (c)="" of="" this="" section="" requires="" to="" be="" removed="" may="" be="" examined="" by="" the="" marine="" inspector.="" (c)(1)="" each="" boiler="" mounting="" may="" be="" removed="" from="" the="" boiler="" and="" be="" examined="" by="" the="" marine="" inspector="" at="" the="" interval="" specified="" by="" table="" 61.05-10="" when="" any="" of="" the="" following="" conditions="" exist:="" *="" *="" *="" *="" *="" (f)="" each="" steam="" gauge="" for="" a="" boiler="" or="" a="" main="" steam="" line="" may="" be="" examined="" and="" checked="" for="" accuracy="" by="" the="" marine="" inspector="" at="" the="" interval="" specified="" by="" table="" 61.05-10.="" (g)="" each="" fusible="" plug="" may="" be="" examined="" by="" the="" marine="" inspector="" at="" the="" interval="" specified="" by="" table="" 61.05-10.="" 39.="" section="" 61.05-20="" is="" revised="" to="" read="" as="" follows:="" sec.="" 61.05-20="" boiler="" safety="" valves.="" each="" safety="" valve="" for="" a="" drum,="" superheater,="" or="" reheater="" of="" a="" boiler="" shall="" be="" tested="" and="" resealed="" in="" the="" presence="" of="" the="" marine="" inspector="" at="" the="" interval="" specified="" by="" table="" 61.05-10.="" 40.="" section="" 61.10-5="" is="" amended="" by="" revising="" the="" heading="" and="" paragraphs="" (a),="" (b),="" (d),="" and="" (g)="" to="" read="" as="" follows:="" sec.="" 61.10-5="" pressure="" vessels="" in="" service.="" (a)="" basic="" requirement.="" each="" pressure="" vessel="" must="" be="" examined="" or="" tested="" twice="" within="" any="" five-year="" period,="" except="" that="" no="" more="" than="" three="" years="" may="" elapse="" between="" any="" test="" or="" examination="" and="" its="" immediate="" predecessor.="" the="" extent="" of="" the="" test="" or="" examination="" should="" be="" that="" necessary="" to="" determine="" that="" the="" pressure="" vessel's="" condition="" is="" satisfactory="" and="" that="" the="" pressure="" vessel="" is="" fit="" for="" the="" service="" intended.="" (b)="" internal="" and="" external="" tests="" and="" inspections.="" each="" pressure="" vessel="" stamped="" with="" the="" coast="" guard="" symbol,="" and="" each="" pressure="" vessel="" in="" a="" system="" regulated="" under="" subpart="" 58.60="" of="" this="" subchapter="" that="" is="" fitted="" with="" a="" manhole="" or="" other="" inspection="" opening="" so="" it="" can="" be="" satisfactorily="" examined="" internally,="" must="" be="" opened="" twice="" within="" any="" five-year="" period,="" except="" that="" no="" more="" than="" three="" years="" may="" elapse="" between="" any="" examination="" and="" its="" immediate="" predecessor.="" each="" pressure="" vessel="" must="" be="" thoroughly="" examined="" internally="" and="" externally.="" no="" pressure="" vessel="" need="" be="" hydrostatically="" tested="" except="" when="" any="" defect="" in="" a="" pressure="" vessel="" is="" found="" that,="" in="" the="" marine="" inspector's="" opinion,="" may="" affect="" the="" safety="" of="" the="" pressure="" vessel;="" in="" this="" case,="" the="" pressure="" vessel="" should="" be="" hydrostatically="" tested="" at="" a="" pressure="" of="" 1\1/="" 2\="" times="" the="" maximum="" allowable="" working="" pressure.="" *="" *="" *="" *="" *="" (d)="" hydrostatic="" tests="" under="" pressure.="" each="" pressure="" vessel,="" other="" than="" one="" exempted="" by="" this="" section,="" must="" be="" subjected="" to="" a="" hydrostatic="" test="" at="" a="" pressure="" of="" 1\1/4\="" times="" the="" maximum="" allowable="" working="" pressure="" twice="" within="" any="" five-year="" period,="" except="" that="" no="" more="" than="" three="" years="" may="" elapse="" between="" any="" test="" and="" its="" immediate="" predecessor.="" *="" *="" *="" *="" *="" (g)="" bulk="" storage="" tanks.="" each="" bulk="" storage="" tank="" containing="" refrigerated="" liquefied="">2 for use aboard a vessel as a fire-
    extinguishing agent shall be subjected to a hydrostatic test of 1\1/2\ 
    times the maximum allowable working pressure in the tenth year of the 
    installation and at ten-year intervals thereafter. After the test, the 
    tank should be drained and an internal examination made. Parts of the 
    jacket and lagging on the underside of the tank designated by the 
    marine inspector must be removed at the time of the test so the marine 
    inspector may determine the external condition of the tank.
    * * * * *
        41. Section 61.15-5 is amended by revising paragraph (b) to read as 
    follows:
    
    
    Sec. 61.15-5  Steam piping.
    
    * * * * *
        (b) All steam piping subject to pressure from the main boiler 
    should be subjected to a hydrostatic test at a pressure of 1\1/4\ times 
    the maximum allowable working pressure of the boiler after every five 
    years of service except as otherwise provided for in paragraph (a) of 
    this section. Unless the covering of the piping is removed, the test 
    pressure must be maintained on the piping for ten minutes. If any 
    evidence of moisture or leakage is detected, the covering should be 
    removed and the piping thoroughly examined. No piping with a nominal 
    size of 3 inches or less need be hydrostatically tested.
    * * * * *
    
    PART 111--ELECTRIC SYSTEMS--GENERAL REQUIREMENTS
    
        42. The authority citation for part 111 is revised to read as 
    follows:
    
        Authority: 46 U.S.C. 2103, 3306, 3703; 49 CFR 1.46.
    
        43. Subpart 111.93 (consisting of Secs. 111.93-1, 111.93-3, 111.93-
    5, 111.93-7, 111.93-9, 111.93-11, and 111.93-13) is removed.
    
    Secs. 111.93-1, 111.93-3, 111.93-5, 111.93-7, 111.93-9, 111.93-11, and 
    111.93-13 (Subpart 111.93)  [Removed]
    
        Dated: April 13, 1995.
    G.N. Naccara,
    Acting Chief, Office of Marine Safety, Security and Environmental 
    Protectoin.
    [FR Doc. 95-10921 Filed 5-9-95; 8:45 am]
    BILLING CODE 4910-14-P
    
    

Document Information

Effective Date:
6/9/1995
Published:
05/10/1995
Department:
Coast Guard
Entry Type:
Rule
Action:
Final rule.
Document Number:
95-10921
Dates:
This final rule is effective on June 9, 1995. The Director of the Federal Register approves as of June 9, 1995 the incorporation by reference of certain materials listed in this rule.
Pages:
24767-24782 (16 pages)
Docket Numbers:
CGD 83-043
RINs:
2115-AB41
PDF File:
95-10921.pdf
CFR: (61)
46 CFR 58.25-10(b)(2)
46 CFR 58.25-25(e)
46 CFR 58.25-10(e)
33 CFR 164.03
33 CFR 164.11
More ...