2018-24747. Testing Regulations for Air Emission Sources  

  • Start Preamble

    AGENCY:

    Environmental Protection Agency (EPA).

    ACTION:

    Final rule.

    SUMMARY:

    This action amends certain existing testing regulations to reflect corrections, updates, and the addition of alternative equipment and methods for source testing of emissions. These revisions will improve the quality of data and provide flexibility in the use of Start Printed Page 56714approved alternative procedures. The revisions do not impose any new substantive requirements on source owners or operators.

    DATES:

    The final rule is effective on January 14, 2019. The incorporation by reference materials listed in the rule are approved by the Director of the Federal Register as of January 14, 2019.

    ADDRESSES:

    The EPA has established a docket for this action under Docket ID No. EPA-HQ-OAR-2016-0510. All documents in the docket are listed on the http://www.regulations.gov website. Although listed in the index, some information is not publicly available, e.g., confidential business information or other information whose disclosure is restricted by statute. Certain other material, such as copyrighted material, is not placed on the internet and will be publicly available only in hard copy. Publicly available docket materials are available electronically through http://www.regulations.gov.

    Start Further Info

    FOR FURTHER INFORMATION CONTACT:

    Ms. Lula H. Melton, Office of Air Quality Planning and Standards, Air Quality Assessment Division (E143-02), Environmental Protection Agency, Research Triangle Park, NC 27711; telephone number: (919) 541-2910; fax number: (919) 541-0516; email address: melton.lula@epa.gov.

    End Further Info End Preamble Start Supplemental Information

    SUPPLEMENTARY INFORMATION:

    The supplementary information in this preamble is organized as follows:

    Table of Contents

    I. General Information

    A. Does this action apply to me?

    B. What action is the agency taking?

    C. Judicial Review

    II. Background

    III. Summary of Amendments

    A. Method 201A of Appendix M of Part 51

    B. Method 204 of Appendix M of Part 51

    C. Method 205 of Appendix M of Part 51

    D. General Provisions (Subpart A) of Part 60

    E. Fossil-Fuel-Fired Steam Generators (Subpart D) Part 60

    F. Electric Utility Steam Generating Units (Subpart Da) Part 60

    G. Industrial-Commercial-Institutional Steam Generating Units (Subpart Db) Part 60

    H. Small Industrial-Commercial-Institutional Steam Generating Units (Subpart Dc) Part 60

    I. Municipal Waste Combustors for Which Construction is Commenced After December 20, 1989 and on or Before September 20, 1994 (Subpart Ea) Part 60

    J. Glass Manufacturing Plants (Subpart CC) Part 60

    K. New Residential Wood Heaters, New Residential Hydronic Heaters and Forced-Air Furnaces (Subpart QQQQ) Part 60

    L. Method 2B of Appendix A-1 of Part 60

    M. Method 5 of Appendix A-3 of Part 60

    N. Method 5B of Appendix A-3 of Part 60

    O. Method 5I of Appendix A-3 of Part 60

    P. Method 7 of Appendix A-4 of Part 60

    Q. Method 8 of Appendix A-4 of Part 60

    R. Method 18 of Appendix A-6 of Part 60

    S. Method 22 of Appendix A-7 of Part 60

    T. Method 26 of Appendix A-8 of Part 60

    U. Method 26A of Appendix A-8 of Part 60

    V. Test Method 28WHH of Appendix A-8 of Part 60

    W. Performance Specification 1 of Appendix B of Part 60

    X. Performance Specification 2 of Appendix B of Part 60

    Y. Performance Specification 3 of Appendix B of Part 60

    Z. Performance Specification 11 of Appendix B of Part 60

    AA. Performance Specification 15 of Appendix B of Part 60

    BB. Performance Specification 18 of Appendix B of Part 60

    CC. Procedure 1 of Appendix F of Part 60

    DD. General Provisions (Subpart A) Part 63

    EE. Wool Fiberglass Manufacturing (Subpart NNN) Part 63

    FF. Major Sources: Industrial, Commercial, and Institutional Boilers and Process Heaters (Subpart DDDDD) Part 63

    GG. Coal- and Oil-Fired Electric Utility Steam Generating Units (Subpart UUUUU) Part 63

    HH. Method 303 of Appendix A of Part 63

    II. Method 308 of Appendix A of Part 63

    JJ. Method 320 of Appendix A of Part 63

    KK. Method 323 of Appendix A of Part 63

    LL. Method 325A of Appendix A of Part 63

    MM. Method 325B of Appendix A of Part 63

    IV. Public Comments on the Proposed Rule

    V. Statutory and Executive Order Reviews

    A. Executive Order 12866: Regulatory Planning and Review and Executive Order 13563: Improving Regulation and Regulatory Review

    B. Executive Order 13771: Reducing Regulations and Controlling Regulatory Costs

    C. Paperwork Reduction Act (PRA)

    D. Regulatory Flexibility Act (RFA)

    E. Unfunded Mandates Reform Act (UMRA)

    F. Executive Order 13132: Federalism

    G. Executive Order 13175: Consultation and Coordination with Indian Tribal Governments

    H. Executive Order 13045: Protection of Children from Environmental Health Risks and Safety Risks

    I. Executive Order 13211: Actions Concerning Regulations That Significantly Affect Energy Supply, Distribution or Use

    J. National Technology Transfer and Advancement Act (NTTAA) and 1 CFR part 51

    K. Executive Order 12898: Federal Actions to Address Environmental Justice in Minority Populations and Low-Income Populations

    L. Congressional Review Act (CRA)

    I. General Information

    A. Does this action apply to me?

    The revisions promulgated in this final rule apply to industries that are subject to the current provisions of 40 Code of Federal Regulations (CFR) parts 51, 60, and 63. We did not list all of the specific affected industries or their North American Industry Classification System (NAICS) codes herein since there are many affected sources in numerous NAICS categories. If you have any questions regarding the applicability of this action to a particular entity, consult either the air permitting authority for the entity or your EPA Regional representative as listed in 40 CFR 63.13.

    B. What action is the agency taking?

    We are promulgating corrections and updates to regulations for source testing of emissions. More specifically, we are correcting typographical and technical errors, updating obsolete testing procedures, adding approved testing alternatives, and clarifying testing requirements.

    C. Judicial Review

    Under section 307(b)(1) of the Clean Air Act (CAA), judicial review of this final rule is available by filing a petition for review in the United States Court of Appeals for the District of Columbia Circuit by January 14, 2019. Under section 307(d)(7)(B) of the CAA, only an objection to this final rule that was raised with reasonable specificity during the period for public comment can be raised during judicial review. Moreover, under section 307(b)(2) of the CAA, the requirements that are the subject of this final rule may not be challenged later in civil or criminal proceedings brought by the EPA to enforce these requirements.

    II. Background

    The revisions to testing regulations for air emission sources were proposed in the Federal Register on January 26, 2018 (83 FR 3636). The public comment period ended March 27, 2018, and 83 comment letters were received from the public; 23 of the comment letters were relevant, and the other 60 comment letters were considered beyond the scope of the proposed rule. This final rule was developed based on public comments that the agency received on the proposed rule.

    III. Summary of Amendments

    A. Method 201A of Appendix M of Part 51

    In Method 201A, in section 12.5, the denominator of equation 24 is corrected Start Printed Page 56715as proposed; the proposed c′p in the denominator is changed to Cp′ to be consistent with the nomenclature in section 12.1. The cp in the numerator is changed to Cp also to be consistent with the nomenclature in section 12.1.

    B. Method 204 of Appendix M of Part 51

    In Method 204, in section 8.2, the statement regarding equation 204-2 is corrected to “The NEAR must be ≤0.05,” as proposed.

    C. Method 205 of Appendix M of Part 51

    In Method 205, section 2.1.1 is revised to allow the use of National Institute of Standards and Technology (NIST)-traceable transfer standards to calibrate the gas dilution system as proposed. The agency continues to believe that these standards are widely available and provide the accuracy necessary to perform the calibration. Section 2.1.1 is also revised as proposed to require testers to report the results of the calibration of the dilution system to enable the regulatory authority to review this information.

    D. General Provisions (Subpart A) of Part 60

    In the General Provisions of part 60, § 60.17(h) is revised as proposed to add ASTM D6216-12 to the list of incorporations by reference and to re-number the remaining consensus standards that are incorporated by reference in alpha-numeric order.

    E. Fossil-Fuel-Fired Steam Generators (Subpart D) Part 60

    In a change from proposal, the allowed filter temperature in § 60.46(b)(2)(i) is not revised. Based on comments we received on the proposed revisions, we are deferring finalizing the proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    F. Electric Utility Steam Generating Units (Subpart Da) Part 60

    In a change from proposal, the allowed filter temperature in § 60.50Da (b)(1)(ii)(A) is not revised. Based on comments we received on the proposed revisions, we are deferring finalizing the proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    G. Industrial-Commercial-Institutional Steam Generating Units (Subpart Db) Part 60

    In a change from proposal, the allowed filter temperature in § 60.46b(d)(4) is not revised. Based on comments we received on the proposed revisions, we are deferring finalizing the proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    H. Small Industrial-Commercial-Institutional Steam Generating Units (Subpart Dc) Part 60

    In a change from proposal, the allowed filter temperature in § 60.45c(a)(5) is not revised. Based on comments we received on the proposed revisions, we are deferring finalizing the proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    I. Municipal Waste Combustors for Which Construction is Commenced After December 20, 1989 and on or Before September 20, 1994 (Subpart Ea) Part 60

    In a change from proposal, the allowed filter temperature in § 60.58a(b)(3) is not revised. Based on comments we received on the proposed revisions, we are deferring finalizing the proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    J. Glass Manufacturing Plants (Subpart CC) Part 60

    In a change from proposal, the allowed filter temperatures in §§ 60.293(f) and 60.296(d)(2) are not revised. Based on comments we received on the proposed revisions, we are deferring finalizing the proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    K. New Residential Wood Heaters, New Residential Hydronic Heaters and Forced-Air Furnaces (Subpart QQQQ) Part 60

    In subpart QQQQ, in Method 28WHH, in section 13.5.1, equation 8 is corrected as proposed.

    L. Method 2B of Appendix A-1 of Part 60

    In Method 2B, in section 12.1, the definition of ambient carbon dioxide concentration is revised as proposed. The agency continues to believe that the global monthly mean (CO2)a concentration varies over time. Also, a website link is added to the definition as specified at proposal.

    M. Method 5 of Appendix A-3 of Part 60

    In a change from proposal, allowed filter temperatures in Method 5, sections 2.0, 6.1.1.2, 6.1.1.6, 6.1.1.7, and 8.5 are not revised. Based on comments we received on the proposed revisions, we are deferring finalizing the proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    Section 6.1.1.9 is revised as proposed to allow the use of a single temperature sensor in lieu of two temperature sensors on the dry gas meter as allowed by Technical Information Document 19 (TID-19) and the approved broadly applicable alternative, ALT-117 (see https://www.epa.gov/​emc). Consistent with our response to the comment regarding allowing flexibility for the weighing container in section 11.2.1, Method 5B, the first sentence in section 11.2.1, Method 5 is revised similarly.

    N. Method 5B of Appendix A-3 of Part 60

    In a change from proposal, the allowed filter temperatures in Method 5B, sections 2.0, 6.1, and 8.2 are not revised. Based on comments we received on the proposed revisions, we are deferring finalizing the proposed revisions of the temperature tolerances of probe and filter holder heating Start Printed Page 56716systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    Section 11.0 is revised as proposed to replace the reference to Method 5, section 11.0 with specific analytical procedures and to report the results using Figure 5B-1 for complete data review. Section 17.0 is revised as proposed to delete the word “Reserved” from the title, and Figure 5B-1 (Analytical Data Sheet) is added.

    O. Method 5I of Appendix A-3 of Part 60

    In a change from proposal, Method 5I, sections 2.1 and 8.5.2.2 are not revised to tighten the allowed filter temperatures. Based on comments we received on the proposed revisions, we are deferring finalizing the proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    P. Method 7 of Appendix A-4 of Part 60

    In Method 7, sections 10.1.2 and 11.3 reference erroneous sections; the correct section is inserted, as proposed. The proposed referenced section 10.1.1.2 is changed to 10.1.1 to include procedures in both sections 10.1.1.1 and 10.1.1.2.

    Q. Method 8 of Appendix A-4 of Part 60

    As proposed, Method 8, sections 6.1.1.1 through 6.1.1.4 are renumbered to 6.1.1.2 through 6.1.1.5; a new section 6.1.1.1 is added to clarify the requirements that apply to the probe nozzle; and, in response to comments, Figure 8-1 (Sulfuric Acid Sampling Train) is corrected by: (1) Modifying the impinger graphics to make it consistent with the text in section 6.1.1.4 and (2) revising the proposed label S-Type Pitot Tube to Type S Pitot Tube for consistency. The proposed first sentence in section 6.1.1.1 is revised to “Borosilicate or quartz glass with a sharp, tapered leading edge and coupled to the probe liner using a polytetrafluoroethylene (PTFE) or glass-lined union (e.g., fused silica, Silico, or equivalent).” Based on a public comment that recommended adding Silco coated stainless steel unions as an option for Teflon unions, and for consistency with other test methods, we have replaced Teflon with the generic option polytetrafluoroethylene (PTFE).

    R. Method 18 of Appendix A-6 of Part 60

    In Method 18, in section 13.1, the erroneous paragraph (c) designation is re-designated as (b), as proposed.

    S. Method 22 of Appendix A-7 of Part 60

    In Method 22, sections 11.2.1 and 11.2.2 are revised as proposed to allow digital photography to be used for a subset of the recordkeeping requirements. As proposed, section 11.2.3 is added to specify the requirements for digital photographic records. In response to comments on the proposal, the next to the last sentence in section 11.2.3 regarding photographs that must be taken within 15 minutes of the observation period is revised from the proposal, and another sentence is added to provide clarity. The revised and new sentences read: “The photograph(s) representing the environmental conditions including the sky conditions and the position of the sun relative to the observer and the emission point must be taken within a reasonable time of the observation (i.e., 15 minutes). When observations are taken from exactly the same observation point on a routine basis (e.g., daily) and as long as there are no modifications to the units depicted, only a single photograph each day is necessary to document the observer's location relative to the emissions source, the process unit being observed, and the location of potential and actual emission points.” The agency notes that ALT-109 (see https://www.epa.gov/​emc) is the associated broadly applicable alternative that allows the use of digital photographs for specific recordkeeping requirements.

    T. Method 26 of Appendix A-8 of Part 60

    As proposed, Method 26, section 6.2.2 is revised to allow the use of glass sample storage containers as an option to allow flexibility and to be consistent with Method 26A. The proposed title of section 6.2.2, “Storage Bottles,” is changed to “Storage Containers” to be consistent with the language in section 6.2.2.

    U. Method 26A of Appendix A-8 of Part 60

    As proposed, in Method 26A, section 6.2.1 is revised to remove the language regarding sample storage containers. In response to comments on our proposal, we have determined that high-density polyethylene is an acceptable material for sample storage containers in addition to the currently allowed glass. Therefore, in a new section 6.2.4., we have specified that both high-density polyethylene and glass are acceptable sample storage containers.

    V. Test Method 28WHH of Appendix A-8 of Part 60

    In Test Method 28WHH, equation 8 in section 13.5.1 is corrected, as proposed.

    W. Performance Specification 1 of Appendix B of Part 60

    As proposed, in Performance Specification 1, references to ASTM D6216-98 (in sections 2.1, 3.1, 6.1, 8.1(1), 8.1(3)(ii), 8.2(1), 8.2(2), 8.2(3), 9.0, 12.1, 13.0, 13.1, 13.2, and 16.0 paragraph 8) are replaced with ASTM D6216-12. As noted at proposal, if the initial certification of the continuous opacity monitoring system (COMS) has already occurred using D6216-98, D6216-03, or D6216-07, it will not be necessary to recertify using D6216-12. In response to comments on our decision to add ASTM D6216 to the list of consensus standards, the April 1998 publication date for ASTM D6216 in paragraph 8 in section 16.0 is replaced with October 2012, the ASTM D6216-12 publication date. In response to comments, for consistency with section 2.1, and for purposes of clarification, the note at the end of section 2.1 is added to section 13.0.

    X. Performance Specification 2 of Appendix B of Part 60

    In Performance Specification 2, section 13.2 is replaced with a table that indicates the relative accuracy performance specifications, as proposed. Given that the equals to (=) signs were erroneously omitted from several of the < and > values during publication of the table in the proposed rule, these values have been corrected.

    Y. Performance Specification 3 of Appendix B of Part 60

    In Performance Specification 3, the two sentences in section 12.0 that read, “Calculate the arithmetic difference between the RM and the CEMS output for each run. The average difference of the nine (or more) data sets constitute the RA.” are deleted, as proposed; these two sentences are no longer necessary since equations 3-1 and 3-2 would be moved from section 13.2 to section 12.0. The sentence, “Calculate the RA using equations 3-1 and 3-2.” is added to the beginning of section 12.0.

    Z. Performance Specification 11 of Appendix B of Part 60

    In Performance Specification 11, section 13.1, the word “average” erroneously exists in the second sentence and is deleted, as proposed.Start Printed Page 56717

    AA. Performance Specification 15 of Appendix B of Part 60

    As proposed, in Performance Specification 15, section 13.0 is added as “Method Performance [Reserved].”

    BB. Performance Specification 18 of Appendix B of Part 60

    As proposed, in Performance Specification 18, in section 11.8.7, the last sentence is revised to clarify the duration of the drift check. In Table 1, the erroneous acronym “NO2” is replaced with “NO,” as proposed. In the appendix of Performance Specification 18, the inadvertently omitted reserved section 12.0 is added, as proposed.

    CC. Procedure 1 of Appendix F of Part 60

    As proposed, in Procedure 1, in section 5.1.2 (1), the sentence immediately following the table that reads, “Challenge the CEMS three times at each audit point, and use the average of the three responses in determining accuracy.” is replaced with, “Introduce each of the audit gases, three times each for a total of six challenges. Introduce the gases in such a manner that the entire CEMS is challenged. Do not introduce the same gas concentration twice in succession.” In order to obtain six distinct readings during the cylinder gas audit (CGA), the same gas must not be introduced twice in succession, and this revised language accurately reflects this standard scientific practice. As also proposed, in section 5.1.2 (3), the reference to EPA's traceability protocol for gaseous calibration standards is updated, and the language regarding the use of EPA Method 205 for dilution of audit gases is clarified.

    DD. General Provisions (Subpart A) of Part 63

    Sections 63.7(g)(2), 63.7(g)(2)(v), and 63.8(e)(5)(i) of the General Provisions (subpart A) of part 63 are revised, as proposed, to require the reporting of specific test data for continuous monitoring system performance evaluation tests and ongoing quality assurance (QA) tests. These data elements are required regardless of the format of the report, i.e., electronic or paper. These modifications will ensure that performance evaluation and QA test reporting include all data necessary for the compliance authority to assess and assure the quality of the reported data and that the reported information describes and identifies the specific unit covered by the evaluation test report. In response to comment, we specified the level of reporting needed for continuous parameter monitoring systems (CPMS) versus other continuous monitoring systems including continuous emission monitoring systems (CEMS), COMS, and predictive emissions monitoring systems (PEMS).

    EE. Wool Fiberglass Manufacturing (Subpart NNN) Part 63

    In a change from proposal, the allowed filter temperature in § 63.1385(a)(5) is not revised. Based on comments we received on the proposed revisions, we are deferring finalizing proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    FF. Major Sources: Industrial, Commercial, and Institutional Boilers and Process Heaters (Subpart DDDDD) Part 63

    As proposed, in Table 6 of subpart DDDDD, row 1.f. is revised to allow the use of EPA SW-846-7471B (for liquid samples) in addition to EPA SW-846-7470A for measuring mercury to allow for compliance flexibility.

    GG. Coal- and Oil-Fired Electric Utility Steam Generating Units (Subpart UUUUU) Part 63

    In a change from proposal, the allowed filter temperature in § 63.10010(h)(7)(i)(1) is not revised. Based on comments we received on the proposed revisions, we are deferring finalizing proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    As proposed, in Table 5, Method 5I is specified as a test method option because, as explained at proposal, Method 5I is designed for low particulate matter (PM) application.

    HH. Method 303 of Appendix A of Part 63

    In Method 303, section 12.4, equation 303-3 is corrected, as proposed, by inserting “where y = ” in front of the equation.

    II. Method 308 of Appendix A of Part 63

    As proposed, in Method 308, deionized distilled water replaces the aqueous n-proponal solution; the affected sections are 2.0, 7.2.2, 7.2.3.3, and 11.3.2. Section 7.2.2, which defines the aqueous n-proponal solution, is removed, as proposed. In section 7.2.3.3, the erroneous “four” is replaced as proposed, with “three” in the sentence that reads “Pipette 5, 15, and 25 ml of this standard, respectively into four 50-ml volumetric flasks.” Section 8.1.2 is revised, as proposed, to require a leak check prior to the sampling run (in addition to after the sampling run) for QA purposes; as explained at proposal, requiring a leak check prior to the sampling run would potentially save time and money. In section 9.1, methanol spike recovery check is added as a quality control (QC) measure in Table 9.1, as proposed. In section 12.1, variables used in equations 308-4 and 308-5 are added and section 12.5, which includes equations 308-4 and 308-5, is added, as proposed. In section 13.0, the title “Reserved” is replaced with “Method Performance” and QA requirements would be added to be consistent with other methods, as proposed. The erroneous proposed paragraph (a) of section 13.0 is replaced, as proposed, with “Calibration standards must meet the requirements in section 10.2.1 or 10.2.2 as applicable.”

    JJ. Method 320 of Appendix A of Part 63

    In section 8.2.2.4, the denominator in equation 2 is corrected from PSS to PS, as proposed. In section 9.2.3, the word “where” in the statement, “Calculate the dilution ratio using the tracer gas as follows: where:” is deleted, as proposed. Also in section 9.2.3, the inadvertently superscripted “dir” on the definition of spike is subscripted, as proposed.

    KK. Method 323 of Appendix A of Part 63

    In Method 323, section 12.9, the denominator in equation 323-8 is corrected, as proposed.

    LL. Method 325A of Appendix A of Part 63

    In Method 325A, section 8.2.1.3 is revised, as proposed, to clarify that only one extra sampling site is required near known sources of volatile organic compounds (VOCs) when the source is located both within 50 meters of the boundary and between two monitors. Based on a public comment we received on the proposed regulatory text, wording changes have been made to the language in section 8.2.1.3. As proposed, the label under Figure 8.1 is corrected from “Refinery (20% angle)” to “Refinery (20° angle).” Section 8.2.3.2 is revised, as proposed, to include facilities with a monitoring perimeter length equal to 7,315 meters (24,000 feet). Section 8.2.3.3 is added, as Start Printed Page 56718proposed, to provide clarification and an equivalent procedure in Option 2 (linear distance between sites) for site locations that parallel section 8.2.2.2.4 in Option 1 (radial distance between sites). In response to comments, section 8.4.3 is added to address worker safety during extenuating circumstances.

    MM. Method 325B of Appendix A of Part 63

    In Method 325B, section 9.3.2 is revised, as proposed, to correct an error in the number of field blank samples required for a sampling period and to provide consistency with the sample analysis required in Method 325B. In sections 9.13 and 11.3.2.5, the erroneous reference to section 10.6.3 is corrected to 10.0, as proposed. Also in section 11.3.2.5, the erroneous reference to section 10.9.5 is corrected to 9.13, as proposed. Section 12.2.2 is revised, as proposed, to correct the calculation of target compound concentrations at standard conditions, and the erroneous reference to Ustd in the note in section 12.2.2 is revised to UNTP. Sections 12.2.3 and 12.2.4 are deleted, as proposed, because the equations for target concentrations are incorrect. Table 17-1 is revised, as proposed, to add inadvertently omitted QC criteria from section 9.3.3.

    IV. Public Comments on the Proposed Rule

    Eighty-three (83) comment letters were received from the public; 23 of the comment letters were relevant, and the other 60 comment letters were considered as beyond the scope of the proposed rule. The public comments and the agency's responses are summarized in the Response to Comments document located in the docket for this rule. See the ADDRESSES section of this preamble.

    A summary of the relevant portions of significant comments that we received on the proposal and agency responses are presented below.

    Comment: Three commenters provided comments on our proposed revisions to the General Provisions (Subpart A) of Part 63. One commenter stated that the proposed revisions impose new requirements on CMS performance evaluations and QA testing for types of monitors not previously subject to such requirements. Another commenter remarked that the proposed revisions to various requirements in Part 63 revisions were vague. Yet another commenter remarked that the proposed revisions to § 63.8(e)(5) would shorten the CMS performance evaluation reporting period for CMS associated with performance tests.

    Response: We disagree with the comment that the proposed changes to § 63.8(e)(5)(i) would impose new requirements given that at proposal, the agency had explained that they were intended to clarify and codify data elements and reporting requirements that are already routinely requested by the Administrator's delegated authorities. With regard to § 63.8(e)(5), in a change from proposal, we have retained the existing requirement that allows for the simultaneous submission of the report of a CMS performance evaluation with results of performance testing required under 40 CFR 63.7. We also edited the final rule language for 40 CFR 63.7(g)(2)(v) to improve clarity and to eliminate confusion.

    Comment: Fifteen commenters provided comments arguing against the proposal to tighten the filter temperature tolerance in 40 CFR 60.46(b)(2)(i); 60.50Da(b)(1)(ii)(A); 60.45c(a)(5); 60.58a(b)(3); 60.293(f); 60.296(d)(2); 63.1385(a)(5); and sections 2.0, 6.1.1.2, 6.1.1.6, 6.1.1.7 and 8.5 of Method 5, Appendix A-3 of Part 60. They cited issues that included: weather (e.g., ambient temperature fluctuations and windy conditions); costs; lack of justification and data for the revision; inconsistent language (e.g., the use of “shall” vs. “may” and proposed revisions to temperature tolerance in Methods 5, 5B, and 5I but not in Methods 5D, 5E, and 5F); and safety risks. Nine commenters remarked that ambient conditions (cold climates, wind gusts, etc.) can cause temperature fluctuations that are difficult to manage. More specifically, one commenter stated that the reduced allowable temperature range would be problematic during testing in cold, windy ambient conditions that are persistent in the winter months in northern climates because the time required for temperature recovery after a component change in these conditions could add hours and possibly days to testing programs. One commenter remarked that the proposed ±5 °C is unattainable for sources in cold or windy climates.

    Eight commenters stated that alteration or replacement of equipment components would likely be necessary to achieve the proposed temperature tolerances resulting in additional costs. One commenter noted potential equipment improvements, such as increased probe sheath tubing diameter to make room for added insulation around every probe heater; re-design of filter heating ovens; improved sealing and insulation of the openings at the inlet and outlet of filter heating ovens; and/or for sources with high stack temperatures, more frequent use of air-cooled or water-cooled probes. One commenter remarked that this revision would force cold weather stack testers to replace or retrofit equipment with higher power heating devices and possibly more refined control devices which would be costly. One commenter remarked that this revision will most likely require air sampling equipment suppliers to redesign sample probes by either increasing sheath diameter, altering the placement or increasing the number of thermocouples used to control the probe heating system, and/or increasing the insulation around the sample liner. The commenter added that an increase in the diameter of the probe sheath would have a cascading effect either requiring test companies to purchase new sample hot boxes or retrofit existing sample hot boxes to accommodate the increased probe sheath diameter.

    Seven commenters stated that neither information nor data was provided to support, justify, or quantify the claimed increased precision of filterable PM measurements, and a few of these commenters noted that the Electric Power Research Institute (EPRI) paper that the EPA used as the basis for tightening the filter temperature tolerance was from a comparison of results measured at four coal-fired power plants.

    One commenter requested that the statement in § 60.50Da(b)(1)(ii)(A), “The probe and filter holder heating system in the sampling train may be set to provide an average gas temperature of no greater than 160 ±5 °C (320 ±9 °F),” be changed to, “The probe and filter holder heating system in the sampling train shall be set to provide an average gas temperature of 160 ±5 °C (320 ±9 °F),” because they believe that this was the agency's intent. Similarly, another commenter requested that the statement in § 60.296(d)(2), “The probe and filter holder heating system may be set to provide a gas temperature no greater than 177 ±5 °C (320 ±9 °F),” be changed to, “The probe and filter holder heating system shall be set to provide an average gas temperature 160 ±5 °C (320 ±9 °F),” because they believe that this was the agency's intent. One commenter also recommended changing the sentence in Method 5B to, “The collected sample is then heated in an oven at 160 °C (320 °F) for 6 hours . . . ,” to, “The collected sample is then heated in an oven at 160 ±5 °C (320 ±9 °F) for 6 hours . . .,” to be internally consistent.

    Three commenters noted that if the temperature tolerances are changed in Method 5, methods that reference Method 5 (namely Method 5D, section Start Printed Page 567192.1; Method 5E, section 2.0; and Method 5F, section 2.0) would also need to be revised.

    Three commenters remarked that tightening the filter temperature tolerance conflicts with the assertion that the proposed rule will improve the quality of data but will not impose new substantive requirements. Two of the three commenters further remarked that the proposed rule does not meet the requirements of Executive Order 13771 nor the Paperwork Reduction Act (PRA).

    Three commenters acknowledged that an improvement in measurement precision could benefit the data quality in limited situations, such as the Mercury and Air Toxics Standards (MATS).

    Four commenters remarked that if the proposed revisions to the temperature tolerances lead to a measurable change in reported PM emissions, sources that were previously in compliance with their emission standards may become non-compliant; one commenter added that the opposite situation may occur. One commenter stated that the proposed revision may have the unintended consequence of redefining the filterable PM being measured leading to either higher or lower PM measurements as compared to sampling runs conducted with wider tolerances.

    Two commenters mentioned that this revision could result in a potential safety risk. One of the commenters remarked that the added weight and handling difficulties associated with air- or water-cooled probes (if necessary to control the probe temperature) can increase safety risks to testing personnel, and the other commenter remarked that the proposed requirements may require the use of encapsulated probes which are heavy and cumbersome resulting in hazards.

    Response: In response to these comments and in a change from proposal, we are deferring finalizing proposed revisions of the temperature tolerances of probe and filter holder heating systems as part of this rulemaking. We will continue to review supporting information and data we received on the proposed rule and may propose either revisions or similar requirements as part of future rulemakings.

    V. Statutory and Executive Order Reviews

    Additional information about these statutes and Executive Orders can be found at http://www2.epa.gov/​laws-regulations/​laws-and-executive-orders.

    A. Executive Order 12866: Regulatory Planning and Review and Executive Order 13563: Improving Regulation and Regulatory Review

    This action is not a significant regulatory action and was, therefore, not submitted to the Office of Management and Budget (OMB) for review.

    B. Executive Order 13771: Reducing Regulations and Controlling Regulatory Costs

    This action is considered an Executive Order 13771 deregulatory action. This final rule provides meaningful burden reduction by allowing regulated facilities the flexibility to use newly-approved alternative procedures for compliance demonstration purposes, which may result in lower labor costs for some facilities (e.g., allowing digital photography in lieu of manual documentation in EPA Method 22); lower compliance testing costs (e.g., additional sample storage container options now allowed by Method 26); reducing the likelihood of re-testing (e.g., revised QA requirements in Method 308); and expediting data processing (e.g., simplified calculations in Method 325B).

    C. Paperwork Reduction Act (PRA)

    This action does not impose an information collection burden under the PRA. The revisions do not substantively revise the existing information collection requirements but simply corrects, updates, and clarifies performance testing and continuous monitoring requirements.

    D. Regulatory Flexibility Act (RFA)

    I certify that this action will not have a significant economic impact on a substantial number of small entities under the RFA. In making this determination, the impact of concern is any significant adverse economic impact on small entities. An agency may certify that a rule will not have a significant economic impact on a substantial number of small entities if the rule relieves regulatory burden, has no net burden or otherwise has a positive economic effect on the small entities subject to the rule. This action will not impose emission measurement requirements beyond those specified in the current regulations, nor does it change any emission standard. We have, therefore, concluded that this action will have no net regulatory burden for all directly regulated small entities.

    E. Unfunded Mandates Reform Act (UMRA)

    This action does not contain any unfunded mandate as described in UMRA, 2 U.S.C. 1531-1538, and does not significantly or uniquely affect small governments. The action imposes no enforceable duty on any state, local or tribal governments or the private sector.

    F. Executive Order 13132: Federalism

    This action does not have federalism implications. It will not have substantial direct effects on the states, on the relationship between the national government and the states, or on the distribution of power and responsibilities among the various levels of government.

    G. Executive Order 13175: Consultation and Coordination With Indian Tribal Governments

    This action does not have tribal implications, as specified in Executive Order 13175. This action simply corrects and updates existing testing regulations. Thus, Executive Order 13175 does not apply to this action.

    H. Executive Order 13045: Protection of Children From Environmental Health Risks and Safety Risks

    The EPA interprets Executive Order 13045 as applying only to those regulatory actions that concern environmental health or safety risks that the EPA has reason to believe may disproportionately affect children, per the definition of “covered regulatory action” in section 2-202 of the Executive Order. This action is not subject to Executive Order 13045 because it does not concern an environmental health risk or safety risk.

    I. Executive Order 13211: Actions Concerning Regulations That Significantly Affect Energy Supply, Distribution or Use

    This action is not subject to Executive Order 13211, because it is not a significant regulatory action under Executive Order 12866.

    J. National Technology Transfer and Advancement Act (NTTAA) and 1 CFR part 51

    This action involves technical standards. The EPA used ASTM D6216-12 for continuous opacity monitors in Performance Specification 1. The ASTM D6216-12 standard covers the procedure for certifying continuous opacity monitors and includes design and performance specifications, test procedures, and QA requirements to ensure that continuous opacity monitors meet minimum design and calibration Start Printed Page 56720requirements necessary, in part, for accurate opacity monitoring measurements in regulatory environmental opacity monitoring applications subject to 10 percent or higher opacity standards.

    The ASTM D6216-12 standard was developed and adopted by the American Society for Testing and Materials (ASTM). The standard may be obtained from http://www.astm.org or from the ASTM at 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959.

    K. Executive Order 12898: Federal Actions To Address Environmental Justice in Minority Populations and Low-Income Populations

    The EPA believes that this action is not subject to Executive Order 12898 (59 FR 7629, February 16, 1994) because it does not establish an environmental health or safety standard. This action is a technical correction to previously promulgated regulatory actions and does not have an impact on human health or the environment.

    L. Congressional Review Act (CRA)

    This action is subject to the CRA, and the EPA will submit a rule report to each house of the Congress and to the Comptroller General of the United States. This action is not a “major rule” as defined by 5 U.S.C. 804(2).

    Start List of Subjects

    List of Subjects

    40 CFR Part 51

    • Environmental protection
    • Air pollution control
    • Performance specifications
    • Test methods and procedures

    40 CFR Part 60

    • Environmental protection
    • Air pollution control
    • Incorporation by reference
    • Performance specifications
    • Test methods and procedures

    40 CFR Part 63

    • Environmental protection
    • Air pollution control
    • Incorporation by reference
    • Performance specifications
    • Test methods and procedures
    End List of Subjects Start Signature

    Dated: November 5, 2018.

    Andrew R. Wheeler,

    Acting Administrator.

    End Signature

    For the reasons stated in the preamble, the Environmental Protection Agency amends title 40, chapter I of the Code of Federal Regulations as follows:

    Start Part

    PART 51—REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS

    End Part Start Amendment Part

    1. The authority citation for part 51 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 23 U.S.C. 101; 42 U.S.C. 7401-7671q.

    End Authority Start Amendment Part

    2. Amend appendix M to part 51 as follows:

    End Amendment Part Start Amendment Part

    a. Revise section 12.5, equation 24, in Method 201A.

    End Amendment Part Start Amendment Part

    b. Revise the last sentence in section 8.2 in Method 204.

    End Amendment Part Start Amendment Part

    c. Revise section 2.1.1 in Method 205.

    End Amendment Part

    The revisions read as follows:

    Appendix M to Part 51—Recommended Test Methods for State Implementation Plans

    * * * * *

    Method 201A—Determination of PM10 and PM2.5 Emissions From Stationary Sources (Constant Sampling Rate Procedure)

    * * * * *

    12.5 * * *

    * * * * *

    Method 204—Criteria for and Verification of a Permanent or Temporary Total Enclosure

    * * * * *

    8.2 * * *

    The NEAR must be ≤0.05.

    * * * * *

    Method 205—Verification of Gas Dilution Systems for Field Instrument Calibrations

    * * * * *

    2.1.1 The gas dilution system shall be recalibrated once per calendar year using NIST-traceable flow standards with an uncertainty ≤0.25 percent. You shall report the results of the calibration by the person or manufacturer who carried out the calibration whenever the dilution system is used, listing the date of the most recent calibration, the due date for the next calibration, calibration point, reference flow device (ID, S/N), and acceptance criteria. Follow the manufacturer's instructions for the operation and use of the gas dilution system. A copy of the manufacturer's instructions for the operation of the instrument, as well as the most recent calibration documentation, shall be made available for inspection at the test site.

    * * * * *
    Start Part

    PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES

    End Part Start Amendment Part

    3. The authority citation for part 60 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 42 U.S.C. 7401 et seq.

    End Authority Start Amendment Part

    4. In § 60.17, revise paragraph (h)(177) to read as follows:

    End Amendment Part
    Incorporations by reference.
    * * * * *

    (h) * * *

    (177) ASTM D6216-12, Standard Practice for Opacity Monitor Manufacturers to Certify Conformance with Design and Performance Specifications, approved October 1, 2012; IBR approved for appendix B to part 60.

    * * * * *
    Start Amendment Part

    5. In Appendix A-1 to part 60, revise “(CO 2)a” in section 12.1 in Method 2B to read as follows:

    End Amendment Part

    Appendix A-1 to Part 60—Test Methods 1 through 2F

    * * * * *

    Method 2B—Determination of Exhaust Gas Volume Flow Rate From Gasoline Vapor Incinerators

    * * * * *

    12.1 * * *

    (CO2)a = Ambient carbon dioxide concentration, ppm (if not measured during the test period, may be assumed to equal the global monthly mean CO2 concentration posted at http://www.esrl.noaa.gov/​gmd/​ccgg/​trends/​global.html#global_​data).

    * * * * *
    Start Amendment Part

    6. In appendix A-3 to part 60:

    End Amendment Part Start Amendment Part

    a. Revise sections 6.1.1.9 and 11.2.1 in Method 5.

    End Amendment Part Start Amendment Part

    b. Revise section 11.0 in Method 5B.

    End Amendment Part Start Amendment Part

    c. Add section 17.0 in Method 5B.

    End Amendment Part

    The revisions and addition read as follows:Start Printed Page 56721

    Appendix A-3 to Part 60—Test Methods 4 through 5I

    * * * * *

    Method 5—Determination of Particulate Matter Emissions From Stationary Sources

    * * * * *

    6.1.1.9 Metering System. Vacuum gauge, leak-free pump, calibrated temperature sensors, dry gas meter (DGM) capable of measuring volume to within 2 percent, and related equipment, as shown in Figure 5-1. Other metering systems capable of maintaining sampling rates within 10 percent of isokinetic and of determining sample volumes to within 2 percent may be used, subject to the approval of the Administrator. When the metering system is used in conjunction with a pitot tube, the system shall allow periodic checks of isokinetic rates. The average DGM temperature for use in the calculations of section 12.0 may be obtained by averaging the two temperature sensors located at the inlet and outlet of the DGM as shown in Figure 5-3 or alternatively from a single temperature sensor located at the immediate outlet of the DGM or the plenum of the DGM.

    * * * * *

    11.2.1 Container No. 1. Leave the contents in the shipping container or transfer the filter and any loose PM from the sample container to a tared weighing container. Desiccate for 24 hours in a desiccator containing anhydrous calcium sulfate. Weigh to a constant weight, and report the results to the nearest 0.1 mg. For the purposes of this section, the term “constant weight” means a difference of no more than 0.5 mg or 1 percent of total weight less tare weight, whichever is greater, between two consecutive weighings, with no less than 6 hours of desiccation time between weighings. Alternatively, the sample may be oven dried at 104 °C (220 °F) for 2 to 3 hours, cooled in the desiccator, and weighed to a constant weight, unless otherwise specified by the Administrator. The sample may be oven dried at 104 °C (220 °F) for 2 to 3 hours. Once the sample has cooled, weigh the sample, and use this weight as a final weight.

    * * * * *

    Method 5B-Determination of Nonsulfuric Acid Particulate Matter Emissions From Stationary Sources

    * * * * *

    11.0 Analytical Procedure

    11.1 Record and report the data required on a sheet such as the one shown in Figure 5B-1.

    11.2 Handle each sample container as follows:

    11.2.1 Container No. 1. Leave the contents in the shipping container or transfer the filter and any loose PM from the sample container to a tared non-reactive oven-proof container. Oven dry the filter sample at a temperature of 160 ±5 °C (320 ±9 °F) for 6 hours. Cool in a desiccator for 2 hours, and weigh to constant weight. Report the results to the nearest 0.1 mg. For the purposes of this section, the term “constant weight” means a difference of no more than 0.5 mg or 1 percent of total weight less tare weight, whichever is greater, between two consecutive weighings, with no less than 6 hours of desiccation time between weighings.

    11.2.2 Container No. 2. Note the level of liquid in the container, and confirm on the analysis sheet whether leakage occurred during transport. If a noticeable amount of leakage has occurred, either void the sample or use methods, subject to the approval of the Administrator, to correct the final results. Measure the liquid in this container either volumetrically to ±1 ml or gravimetrically to ±0.5 g. Transfer the contents to a tared 250 ml beaker, and evaporate to dryness at ambient temperature and pressure. Then oven dry the probe sample at a temperature of 160 ±5 °C (320 ±9 °F) for 6 hours. Cool in a desiccator for 2 hours, and weigh to constant weight. Report the results to the nearest 0.1 mg.

    11.2.3 Container No. 3. Weigh the spent silica gel (or silica gel plus impinger) to the nearest 0.5 g using a balance. This step may be conducted in the field.

    11.2.4 Acetone Blank Container. Measure the acetone in this container either volumetrically or gravimetrically. Transfer the acetone to a tared 250 ml beaker, and evaporate to dryness at ambient temperature and pressure. Desiccate for 24 hours, and weigh to a constant weight. Report the results to the nearest 0.1 mg.

    Note: The contents of Container No. 2 as well as the acetone blank container may be evaporated at temperatures higher than ambient. If evaporation is done at an elevated temperature, the temperature must be below the boiling point of the solvent; also, to prevent “bumping,” the evaporation process must be closely supervised, and the contents of the beaker must be swirled occasionally to maintain an even temperature. Use extreme care, as acetone is highly flammable and has a low flash point.

    * * * * *

    17.0 Tables, Diagrams, Flowcharts, and Validation Data

    Container numberWeight of particulate collected, mg
    Final weightTare weightWeight gain
    1.
    2.
    Total:
    Less acetone blank
    Weight of particulate matter
    Volume of liquid water collected
    Impinger volume,Silica gel weight,
    mlg
    Final
    Initial
    Liquid collected
    Total volume collectedg* ml
    * Convert weight of water to volume by dividing total weight increase by density of water (1 g/ml).

    Figure 5B-1. Analytical Data Sheet

    * * * * *
    Start Amendment Part

    7. In appendix A-4 to part 60:

    End Amendment Part Start Amendment Part

    a. Revise sections 10.1.2 and 11.3 in Method 7.

    End Amendment Part Start Amendment Part

    b. Redesignate sections 6.1.1.1 through 6.1.1.4 as sections 6.1.1.2 through 6.1.1.5 in Method 8.

    End Amendment Part Start Amendment Part

    c. Add a new section 6.1.1.1 in Method 8.

    End Amendment Part Start Amendment Part

    d. Revise Figure 8-1 in Method 8.

    End Amendment Part

    The revisions and addition read as follows:

    Appendix A-4 to Part 60—Test Methods 6 Through 10B

    * * * * *
    Start Printed Page 56722

    Method 7—Determination of Nitrogen Oxide Emissions From Stationary Sources

    * * * * *

    10.1.2 Determination of Spectrophotometer Calibration Factor Kc. Add 0 ml, 2.0 ml, 4.0 ml, 6.0 ml, and 8.0 ml of the KNO3 working standard solution (1 ml = 100 µg NO2) to a series of five 50-ml volumetric flasks. To each flask, add 25 ml of absorbing solution and 10 ml water. Add 1 N NaOH to each flask until the pH is between 9 and 12 (about 25 to 35 drops). Dilute to the mark with water. Mix thoroughly, and pipette a 25-ml aliquot of each solution into a separate porcelain evaporating dish. Beginning with the evaporation step, follow the analysis procedure of section 11.2 until the solution has been transferred to the 100-ml volumetric flask and diluted to the mark. Measure the absorbance of each solution at the optimum wavelength as determined in section 10.1.1. This calibration procedure must be repeated on each day that samples are analyzed. Calculate the spectrophotometer calibration factor as shown in section 12.2.

    * * * * *

    11.3 Sample Analysis. Mix the contents of the flask thoroughly, and measure the absorbance at the optimum wavelength used for the standards (section 10.1.1), using the blank solution as a zero reference. Dilute the sample and the blank with equal volumes of water if the absorbance exceeds A4, the absorbance of the 400-µg NO2 standard (see section 10.1.3).

    * * * * *

    Method 8—Determination of Sulfuric Acid and Sulfur Dioxide Emissions From Stationary Sources

    * * * * *

    6.1.1.1 Probe Nozzle. Borosilicate or quartz glass with a sharp, tapered leading edge and coupled to the probe liner using a polytetrafluoroethylene (PTFE) or glass-lined union (e.g., fused silica, Slico, or equivalent). When the stack temperature exceeds 210 °C (410 °F), a leak-free ground glass fitting or other leak free, non-contaminating fitting must be used to couple the nozzle to the probe liner. It is also acceptable to use a one-piece glass nozzle/liner assembly. The angle of the taper shall be ≤30°, and the taper shall be on the outside to preserve a constant internal diameter. The probe nozzle shall be of the button-hook or elbow design, unless otherwise specified by the Administrator. Other materials of construction may be used, subject to the approval of the Administrator. A range of nozzle sizes suitable for isokinetic sampling should be available. Typical nozzle sizes range from 0.32 to 1.27 cm (1/8 to 1/2 in) inside diameter (ID) in increments of 0.16 cm (1/16 in). Larger nozzles sizes are also available if higher volume sampling trains are used.

    * * * * *

    17.0 * * *

    Start Printed Page 56723
    * * * * *

    Appendix A-6 to Part 60—[Amended]

    Start Amendment Part

    8. In Appendix A-6 to part 60, redesignate paragraph (c) as paragraph (b) in section 13.1 in Method 18.

    End Amendment Part Start Amendment Part

    9. In appendix A-7 to part 60:

    End Amendment Part Start Amendment Part

    a. Revise sections 11.2.1 and 11.2.2 in Method 22.

    End Amendment Part Start Amendment Part

    b. Add section 11.2.3 in Method 22.

    End Amendment Part

    The revisions and addition read as follows:

    Appendix A-7 to Part 60—Test Methods 19 Through 25E

    * * * * *

    Method 22—Visual Determination of Fugitive Emissions From Material Sources and Smoke Emissions From Flares

    * * * * *

    11.2.1 Outdoor Location. Record the following information on the field data sheet (Figure 22-1): Company name, industry, process unit, observer's name, observer's affiliation, and date. Record also the estimated wind speed, wind direction, and sky condition. Sketch the process unit being observed, and note the observer location relative to the source and the sun. Indicate the potential and actual emission points on the sketch. Alternatively, digital photography as described in section 11.2.3 may be used for a subset of the recordkeeping requirements of this section.

    11.2.2 Indoor Location. Record the following information on the field data sheet (Figure 22-2): Company name, industry, process unit, observer's name, observer's affiliation, and date. Record as appropriate the type, location, and intensity of lighting on the data sheet. Sketch the process unit being observed, and note the observer location relative to the source. Indicate the potential and actual fugitive emission points on the sketch. Alternatively, digital photography as described in section 11.2.3 may be used for a subset of the recordkeeping requirements of this section.

    11.2.3 Digital Photographic Records. Digital photographs, annotated or unaltered, may be used to record and report sky conditions, observer's location relative to the source, observer's location relative to the sun, process unit being observed, potential emission points and actual emission points for the requirements in sections 11.2.1 and 11.2.2. The image must have the proper lighting, field of view and depth of field to properly distinguish the sky condition (if applicable), process unit, potential emission point and actual emission point. At least one digital photograph must be from the point of the view of the observer. The photograph(s) representing the environmental conditions including the sky conditions and the position of the sun relative to the observer and the emission point must be taken within a reasonable time of the observation (i.e., 15 minutes). When observations are taken from exactly the same observation point on a routine basis (i.e., daily) and as long as there are no modifications to the units depicted, only a single photograph each is necessary to document the observer's location relative to the emissions source, the process unit being observed, and the location of potential and actual emission points. Any photographs altered or annotated must be retained in an unaltered format for recordkeeping purposes.

    * * * * *
    Start Amendment Part

    10. In appendix A-8 to part 60:

    End Amendment Part Start Amendment Part

    a. Revise section 6.2.2 in Method 26.

    End Amendment Part Start Amendment Part

    b. Revise section 6.2.1 in Method 26A.

    End Amendment Part Start Amendment Part

    c. Add section 6.2.4 in Method 26A.

    End Amendment Part Start Amendment Part

    d. Revise equation 8 in section 13.5.1 in Test Method 28WHH.

    End Amendment Part

    The revisions and additions read as follows:

    Appendix A-8 to Part 60—Test Methods 26 Through 30B

    * * * * *

    Method 26—Determination of Hydrogen Halide and Halogen Emissions From Stationary Sources Non-Isokinetic Method

    * * * * *

    6.2.2 Storage Containers. 100- or 250-ml, high-density polyethylene or glass sample storage containers with Teflon screw cap liners to store impinger samples.

    * * * * *

    Method 26A—Determination of Hydrogen Halide and Halogen Emissions From Stationary Sources Isokinetic Method

    * * * * *

    6.2.1 Probe-Liner and Probe-Nozzle Brushes, Wash Bottles, Petri Dishes, Graduated Cylinder and/or Balance, and Rubber Policeman. Same as Method 5, sections 6.2.1, 6.2.2, 6.2.4, 6.2.5, and 6.2.7.

    * * * * *

    6.2.4 Sample Storage Containers. High-density polyethylene or glass sample storage containers with Teflon screw cap liners to store impinger samples.

    * * * * *

    Test Method 28WHH for Measurement of Particulate Emissions and Heating Efficiency of Wood-Fired Hydronic Heating Appliances

    * * * * *

    13.5.1 * * *

    * * * * *
    Start Amendment Part

    11. In appendix B to part 60:

    End Amendment Part Start Amendment Part

    a. Add the following entries to the list of Performance Specifications in numeric order:

    End Amendment Part Start Amendment Part

    i. Performance Specification 12B—Specifications and Test Procedures for Monitoring Total Vapor Phase Mercury Emissions From Stationary Sources Using A Sorbent Trap Monitoring System

    End Amendment Part Start Amendment Part

    ii. Performance Specification 17 [Reserved]

    End Amendment Part Start Amendment Part

    iii. Performance Specification 18—Performance Specifications and Test Procedures for Gaseous Hydrogen Chloride (HCl) Continuous Emission Monitoring Systems at Stationary Sources

    End Amendment Part Start Amendment Part

    iv. PS-18—Appendix A Standard Addition Procedures

    End Amendment Part Start Amendment Part

    b. In Performance Specification 1, remove “D 6216-98” wherever it appears and add in its place “D6216-12”, and revise section 2.1, the introductory text of section 13.0, sections 13.1 and 13.2, and paragraph 8. of section 16.0.

    End Amendment Part Start Amendment Part

    c. In Performance Specification 2, revise section 13.2.

    End Amendment Part Start Amendment Part

    d. In Performance Specification 3, revise sections 12.0 and 13.2.

    End Amendment Part Start Amendment Part

    e. In Performance Specification 11, revise section 13.1.

    End Amendment Part Start Amendment Part

    f. In Performance Specification 15, add reserved section 13.0.

    End Amendment Part Start Amendment Part

    g. In Performance Specification 18, revise section 11.8.7 and table 1 in section 17.0, and add reserved section 12.0 to PS-18.

    End Amendment Part

    The revisions and additions read as follows:

    Appendix B to Part 60—Performance Specifications

    * * * * *

    Performance Specification 1—Specifications and Test Procedures for Continuous Opacity Monitoring Systems in Stationary Sources

    * * * * *

    2.1 ASTM D6216-12 (incorporated by reference, see § 60.17) is the reference for design specifications, manufacturer's performance specifications, and test procedures. The opacity monitor manufacturer must periodically select and test an opacity monitor, that is representative of a group of monitors produced during a specified period or lot, for conformance with the design specifications in ASTM D6216-12. The opacity monitor manufacturer must test each opacity monitor for conformance with the manufacturer's performance specifications in ASTM D6216-12. Note: If the initial certification of the opacity monitor occurred before November 14, 2018 using D6216-98, D6216-03, or D6216-07, it is not necessary to recertify using D6216-12.

    * * * * *

    13.0 What Specifications Does a COMS Have to Meet for Certification?Start Printed Page 56724

    A COMS must meet the following design, manufacturer's performance, and field audit performance specifications:

    Note: If the initial certification of the opacity monitor occurred before November 14, 2018 using D6216-98, D6216-03, or D6216-07, it is not necessary to recertify using D6216-12.A. COMS must meet the following design, manufacturer's performance, and field audit performance specifications.

    13.1 Design Specifications. The opacity monitoring equipment must comply with the design specifications of ASTM D6216-12.

    13.2 Manufacturer's Performance Specifications. The opacity monitor must comply with the manufacturer's performance specifications of ASTM D6216-12.

    * * * * *

    16.0 * * *

    8. ASTM D6216-12: Standard Practice for Opacity Monitor Manufacturers to Certify Conformance with Design and Performance Specifications. ASTM. October 2012.

    * * * * *

    Performance Specification 2—Specifications and Test Procedures for SO2 and NOX Continuous Emission Monitoring Systems in Stationary Sources

    * * * * *

    13.2 Relative Accuracy Performance Specification.

    Calculate . . .RA criteria (%)
    If average emissions during the RATA are ≥50% of emission standardUse Eq. 2-6, with RM in the denominator≤20.0
    If average emissions during the RATA are <50% of emission standardUse Eq. 2-6, emission standard in the denominator≤10.0
    For SO2 emission standards ≤130 but ≥86 ng/J (0.30 and 0.20 lb/million Btu)Use Eq. 2-6, emission standard in the denominator≤15.0
    For SO2 emission standards <86 ng/J (0.20 lb/million Btu)Use Eq. 2-6, emission standard in the denominator≤20.0
    * * * * *

    Performance Specification 3—Specifications and Test Procedures for O2 and CO2 Continuous Emission Monitoring Systems in Stationary Sources

    * * * * *

    12.0 Calculations and Data Analysis

    Calculate the RA using equations 3-1 and 3-2. Summarize the results on a data sheet similar to that shown in Figure 2.2 of PS2.

    * * * * *

    13.2 CEMS Relative Accuracy Performance Specification. The RA of the CEMS must be no greater than 20.0 percent of the mean value of the reference method (RM) data when calculated using equation 3-1. The results are also acceptable if the result of Equation 3-2 is less than or equal to 1.0 percent O2 (or CO2).

    * * * * *

    Performance Specification 11—Specifications and Test Procedures for Particulate Matter Continuous Emission Monitoring Systems at Stationary Sources

    * * * * *

    13.1 What is the 7-day drift check performance specification? Your daily PM CEMS internal drift checks must demonstrate that the daily drift of your PM CEMS does not deviate from the value of the reference light, optical filter, Beta attenuation signal, or other technology-suitable reference standard by more than 2 percent of the response range. If your CEMS includes diluent and/or auxiliary monitors (for temperature, pressure, and/or moisture) that are employed as a necessary part of this performance specification, you must determine the calibration drift separately for each ancillary monitor in terms of its respective output (see the appropriate performance specification for the diluent CEMS specification). None of the calibration drifts may exceed their individual specification.

    * * * * *
    Start Printed Page 56725

    Performance Specification 15—Performance Specification for Extractive FTIR Continuous Emissions Monitor Systems in Stationary Sources

    * * * * *

    13.0 Method Performance [Reserved]

    * * * * *

    Performance Specification 18—Performance Specifications and Test Procedures for Gaseous Hydrogen Chloride (HCl) Continuous Emission Monitoring Systems at Stationary Sources

    * * * * *

    11.8.7 The zero-level and mid-level CD for each day must be less than 5.0 percent of the span value as specified in section 13.2 of this PS. You must meet this criterion for 7 consecutive operating days.

    * * * * *

    17.0 * * *

    Table 1—Interference Test Gas Concentrations

    Potential interferent gas 1Approximate concentration (balance N2)
    CO215% ± 1% CO2.2
    CO100 ± 20 ppm.
    CH2 O20 ± 5 ppm.
    CH4100 ± 20 ppm.
    NH310 ± 5 ppm (extractive CEMS only).
    NO250 ± 50 ppm.
    SO2200 ± 20 ppm.
    O23% ± 1% O2.2
    H2 O10% ± 1% H2 O.2
    N2Balance.2
    1 Any of these specific gases can be tested at a lower level if the manufacturer has provided reliable means for limiting or scrubbing that gas to a specified level in CEMS field installations.
    2 Gases for short path IP cell interference tests cannot be added above 100 percent stack equivalent concentration. Add these gases at the indicated percentages to make up the remaining cell volume.
    * * * * *

    PS-18 Appendix A Standard Addition Procedures

    * * * * *

    12.0 [Reserved]

    * * * * *
    Start Amendment Part

    12. Revise sections 5.1.2(1) and (3) in Procedure 1 of appendix F to part 60 to read as follows:

    End Amendment Part

    Appendix F to Part 60—Quality Assurance Procedures

    Procedure 1—Quality Assurance Requirements for Gas Continuous Emission Monitoring Systems Used For Compliance Determination

    * * * * *

    5.1.2 * * *

    (1) Challenge the CEMS (both pollutant and diluent portions of the CEMS, if applicable) with an audit gas of known concentration at two points within the following ranges:

    Audit pointAudit range
    Pollutant monitorsDiluent monitors for—
    CO2O2
    120 to 30% of span value5 to 8% by volume4 to 6% by volume.
    250 to 60% of span value10 to 14% by volume8 to 12% by volume.

    Introduce each of the audit gases, three times each for a total of six challenges. Introduce the gases in such a manner that the entire CEMS is challenged. Do not introduce the same gas concentration twice in succession.

    Use of separate audit gas cylinder for audit points 1 and 2. Do not dilute gas from audit cylinder when challenging the CEMS.

    The monitor should be challenged at each audit point for a sufficient period of time to assure adsorption-desorption of the CEMS sample transport surfaces has stabilized.

    * * * * *

    (3) Use Certified Reference Materials (CRM's) (See Citation 1) audit gases that have been certified by comparison to National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM's) or EPA Protocol Gases following the most recent edition of the EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards (See Citation 2). Procedures for preparation of CRM's are described in Citation 1. Procedures for preparation of EPA Protocol Gases are described in Citation 2. In the case that a suitable audit gas level is not commercially available, Method 205 (See Citation 3) may be used to dilute CRM's or EPA Protocol Gases to the needed level. The difference between the actual concentration of the audit gas and the concentration indicated by the monitor is used to assess the accuracy of the CEMS.

    * * * * *
    Start Part

    PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES

    End Part Start Amendment Part

    13. The authority citation for part 63 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 42 U.S.C. 7401 et seq.

    End Authority Start Amendment Part

    14. In § 63.7, revise paragraphs (g)(2) introductory text and (g)(2)(v) to read as follows:

    End Amendment Part
    Performance testing requirements.
    * * * * *

    (g) * * *

    (2) Contents of a performance test, CMS performance evaluation, or CMS quality assurance test report (electronic or paper submitted copy). Unless otherwise specified in a relevant standard, test method, CMS performance specification, or quality assurance requirement for a CMS, or as otherwise approved by the Administrator in writing, the report shall include the elements identified in paragraphs (g)(2)(i) through (vi) of this section.

    * * * * *

    (v) Where a test method, CEMS, PEMS, or COMS performance specification, or on-going quality assurance requirement for a CEMS, PEMS, or COMS requires you record or report, the following shall be included in your report: Record of preparation of standards, record of calibrations, raw data sheets for field sampling, raw data sheets for field and laboratory analyses, chain-of-custody documentation, and example calculations for reported results.

    * * * * *
    Start Amendment Part

    15. In § 63.8, revise paragraph (e)(5)(i) to read as follows:

    End Amendment Part
    Monitoring requirements.
    * * * * *

    (e) * * *

    (5) * * * (i) The owner or operator shall furnish the Administrator a copy of a written report of the results of the performance evaluation containing the information specified in § 63.7(g)(2)(i) through (vi) simultaneously with the results of the performance test required under § 63.7 or within 60 days of completion of the performance evaluation, unless otherwise specified in a relevant standard.

    * * * * *
    Start Amendment Part

    16. Revise Table 6 to Subpart DDDDD of part 63 to read as follows:

    End Amendment Part

    Table 6 to Subpart DDDDD of Part 63—Fuel Analysis Requirements

    As stated in § 63.7521, you must comply with the following requirements Start Printed Page 56726for fuel analysis testing for existing, new or reconstructed affected sources. However, equivalent methods (as defined in § 63.7575) may be used in lieu of the prescribed methods at the discretion of the source owner or operator:

    To conduct a fuel analysis for the following pollutant . . .You must . . .Using . . .
    1. Mercurya. Collect fuel samplesProcedure in § 63.7521(c) or ASTM D5192a, or ASTM D7430a, or ASTM D6883a, or ASTM D2234/D2234Ma (for coal) or EPA 1631 or EPA 1631E or ASTM D6323a (for solid), or EPA 821-R-01-013 (for liquid or solid), or ASTM D4177a (for liquid), or ASTM D4057a (for liquid), or equivalent.
    b. Composite fuel samplesProcedure in § 63.7521(d) or equivalent.
    c. Prepare composited fuel samplesEPA SW-846-3050Ba (for solid samples), ASTM D2013/D2013Ma (for coal), ASTM D5198a (for biomass), or EPA 3050a (for solid fuel), or EPA 821-R-01-013a (for liquid or solid), or equivalent.
    d. Determine heat content of the fuel typeASTM D5865a (for coal) or ASTM E711a (for biomass), or ASTM D5864a for liquids and other solids, or ASTM D240a or equivalent.
    e. Determine moisture content of the fuel typeASTM D3173a, ASTM E871a, or ASTM D5864a, or ASTM D240a, or ASTM D95a (for liquid fuels), or ASTM D4006a (for liquid fuels), or equivalent.
    f. Measure mercury concentration in fuel sampleASTM D6722a (for coal), EPA SW-846-7471Ba or EPA 1631 or EPA 1631Ea (for solid samples), or EPA SW-846-7470Aa or EPA SW-846-7471Ba (for liquid samples), or EPA 821-R-01-013a (for liquid or solid), or equivalent.
    g. Convert concentration into units of pounds of mercury per MMBtu of heat contentFor fuel mixtures use Equation 8 in § 63.7530.
    2. HCla. Collect fuel samplesProcedure in § 63.7521(c) or ASTM D5192a, or ASTM D7430a, or ASTM D6883a, or ASTM D2234/D2234Ma (for coal) or ASTM D6323a (for coal or biomass), ASTM D4177a (for liquid fuels) or ASTM D4057a (for liquid fuels), or equivalent.
    b. Composite fuel samplesProcedure in § 63.7521(d) or equivalent.
    c. Prepare composited fuel samplesEPA SW-846-3050Ba (for solid samples), ASTM D2013/D2013Ma (for coal), or ASTM D5198a (for biomass), or EPA 3050a or equivalent.
    d. Determine heat content of the fuel typeASTM D5865a (for coal) or ASTM E711a (for biomass), ASTM D5864a, ASTM D240a or equivalent.
    e. Determine moisture content of the fuel typeASTM D3173a or ASTM E871a, or D5864a, or ASTM D240a, or ASTM D95a (for liquid fuels), or ASTM D4006a (for liquid fuels), or equivalent.
    f. Measure chlorine concentration in fuel sampleEPA SW-846-9250a, ASTM D6721a, ASTM D4208a (for coal), or EPA SW-846-5050a or ASTM E776a (for solid fuel), or EPA SW-846-9056a or SW-846-9076a (for solids or liquids) or equivalent.
    g. Convert concentrations into units of pounds of HCl per MMBtu of heat contentFor fuel mixtures use Equation 7 in § 63.7530 and convert from chlorine to HCl by multiplying by 1.028.
    3. Mercury Fuel Specification for other gas 1 fuelsa. Measure mercury concentration in the fuel sample and convert to units of micrograms per cubic meter, orMethod 30B (M30B) at 40 CFR part 60, appendix A-8 of this chapter or ASTM D5954a, ASTM D6350a, ISO 6978-1:2003(E)a, or ISO 6978-2:2003(E)a, or EPA-1631a or equivalent.
    b. Measure mercury concentration in the exhaust gas when firing only the other gas 1 fuel is fired in the boiler or process heaterMethod 29, 30A, or 30B (M29, M30A, or M30B) at 40 CFR part 60, appendix A-8 of this chapter or Method 101A or Method 102 at 40 CFR part 61, appendix B of this chapter, or ASTM Method D6784a or equivalent.
    4. TSMa. Collect fuel samplesProcedure in § 63.7521(c) or ASTM D5192a, or ASTM D7430a, or ASTM D6883a, or ASTM D2234/D2234Ma (for coal) or ASTM D6323a (for coal or biomass), or ASTM D4177a, (for liquid fuels), or ASTM D4057a (for liquid fuels), or equivalent.
    b. Composite fuel samplesProcedure in § 63.7521(d) or equivalent.
    c. Prepare composited fuel samplesEPA SW-846-3050Ba (for solid samples), ASTM D2013/D2013Ma (for coal), ASTM D5198a or TAPPI T266a (for biomass), or EPA 3050a or equivalent.
    d. Determine heat content of the fuel typeASTM D5865a (for coal) or ASTM E711a (for biomass), or ASTM D5864a for liquids and other solids, or ASTM D240a or equivalent.
    e. Determine moisture content of the fuel typeASTM D3173a or ASTM E871a, or D5864a, or ASTM D240a, or ASTM D95a (for liquid fuels), or ASTM D4006a (for liquid fuels), or ASTM D4177a (for liquid fuels) or ASTM D4057a (for liquid fuels), or equivalent.
    f. Measure TSM concentration in fuel sampleASTM D3683a, or ASTM D4606a, or ASTM D6357a or EPA 200.8a or EPA SW-846-6020a, or EPA SW-846-6020Aa, or EPA SW-846-6010Ca, EPA 7060a or EPA 7060Aa (for arsenic only), or EPA SW-846-7740a (for selenium only).
    Start Printed Page 56727
    g. Convert concentrations into units of pounds of TSM per MMBtu of heat contentFor fuel mixtures use Equation 9 in § 63.7530.
    a Incorporated by reference, see § 63.14.
    * * * * *
    Start Amendment Part

    17. Revise Table 5 to Subpart UUUUU of part 63 to read as follows:

    End Amendment Part

    Table 5 to Subpart UUUUU of Part 63—Performance Testing Requirements

    As stated in § 63.10007, you must comply with the following requirements for performance testing for existing, new or reconstructed affected sources: [1]

    To conduct a performance test for the following pollutant . . .Using . . .You must perform the following activities, as applicable to your input- or output-based emission limit . . .Using . . .2
    1. Filterable Particulate matter (PM)Emissions Testinga. Select sampling ports location and the number of traverse pointsMethod 1 at appendix A-1 to part 60 of this chapter.
    b. Determine velocity and volumetric flow-rate of the stack gasMethod 2, 2A, 2C, 2F, 2G or 2H at appendix A-1 or A-2 to part 60 of this chapter.
    c. Determine oxygen and carbon dioxide concentrations of the stack gasMethod 3A or 3B at appendix A-2 to part 60 of this chapter, or ANSI/ASME PTC 19.10-1981.3
    d. Measure the moisture content of the stack gasMethod 4 at appendix A-3 to part 60 of this chapter.
    e. Measure the filterable PM concentrationMethods 5 and 5I at appendix A-3 to part 60 of this chapter. For positive pressure fabric filters, Method 5D at appendix A-3 to part 60 of this chapter for filterable PM emissions. Note that the Method 5 or 5I front half temperature shall be 160° ±14 °C (320° ±25 °F).
    f. Convert emissions concentration to lb/MMBtu or lb/MWh emissions ratesMethod 19 F-factor methodology at appendix A-7 to part 60 of this chapter, or calculate using mass emissions rate and gross output data (see § 63.10007(e)).
    OROR
    PM CEMSa. Install, certify, operate, and maintain the PM CEMSPerformance Specification 11 at appendix B to part 60 of this chapter and Procedure 2 at appendix F to part 60 of this chapter.
    b. Install, certify, operate, and maintain the diluent gas, flow rate, and/or moisture monitoring systemsPart 75 of this chapter and § 63.10010(a), (b), (c), and (d).
    c. Convert hourly emissions concentrations to 30 boiler operating day rolling average lb/MMBtu or lb/MWh emissions ratesMethod 19 F-factor methodology at appendix A-7 to part 60 of this chapter, or calculate using mass emissions rate and gross output data (see § 63.10007(e)).
    2. Total or individual non-Hg HAP metalsEmissions Testinga. Select sampling ports location and the number of traverse pointsMethod 1 at appendix A-1 to part 60 of this chapter.
    b. Determine velocity and volumetric flow-rate of the stack gasMethod 2, 2A, 2C, 2F, 2G or 2H at appendix A-1 or A-2 to part 60 of this chapter.
    c. Determine oxygen and carbon dioxide concentrations of the stack gasMethod 3A or 3B at appendix A-2 to part 60 of this chapter, or ANSI/ASME PTC 19.10-1981.3
    d. Measure the moisture content of the stack gasMethod 4 at appendix A-3 to part 60 of this chapter.
    Start Printed Page 56728
    e. Measure the HAP metals emissions concentrations and determine each individual HAP metals emissions concentration, as well as the total filterable HAP metals emissions concentration and total HAP metals emissions concentrationMethod 29 at appendix A-8 to part 60 of this chapter. For liquid oil-fired units, Hg is included in HAP metals and you may use Method 29, Method 30B at appendix A-8 to part 60 of this chapter; for Method 29, you must report the front half and back half results separately. When using Method 29, report metals matrix spike and recovery levels.
    f. Convert emissions concentrations (individual HAP metals, total filterable HAP metals, and total HAP metals) to lb/MMBtu or lb/MWh emissions ratesMethod 19 F-factor methodology at appendix A-7 to part 60 of this chapter, or calculate using mass emissions rate and gross output data (see § 63.10007(e)).
    3. Hydrogen chloride (HCl) and hydrogen fluoride (HF)Emissions Testinga. Select sampling ports location and the number of traverse pointsMethod 1 at appendix A-1 to part 60 of this chapter.
    b. Determine velocity and volumetric flow-rate of the stack gasMethod 2, 2A, 2C, 2F, 2G or 2H at appendix A-1 or A-2 to part 60 of this chapter.
    c. Determine oxygen and carbon dioxide concentrations of the stack gasMethod 3A or 3B at appendix A-2 to part 60 of this chapter, or ANSI/ASME PTC 19.10-1981.3
    d. Measure the moisture content of the stack gasMethod 4 at appendix A-3 to part 60 of this chapter.
    e. Measure the HCl and HF emissions concentrationsMethod 26 or Method 26A at appendix A-8 to part 60 of this chapter or Method 320 at appendix A to part 63 of this chapter or ASTM D6348-03 3 with
    (1) the following conditions when using ASTM D6348-03:
    (A) The test plan preparation and implementation in the Annexes to ASTM D6348-03, Sections A1 through A8 are mandatory;
    (B) For ASTM D6348-03 Annex A5 (Analyte Spiking Technique), the percent (%) R must be determined for each target analyte (see Equation A5.5);
    (C) For the ASTM D6348-03 test data to be acceptable for a target analyte, %R must be 70% ≥R ≤130%; and

    3.e.1(D) The %R value for each compound must be reported in the test report and all field measurements corrected with the calculated %R value for that compound using the following equation:

    and

    To conduct a performance test for the following pollutant . . . (cont'd)Using . . . (cont'd)You must perform the following activities, as applicable to your input- or output-based emission limit . . . (cont'd)Using . . .2 (cont'd)
    (2) spiking levels nominally no greater than two times the level corresponding to the applicable emission limit.
    Method 26A must be used if there are entrained water droplets in the exhaust stream.
    Start Printed Page 56729
    f. Convert emissions concentration to lb/MMBtu or lb/MWh emissions ratesMethod 19 F-factor methodology at appendix A-7 to part 60 of this chapter, or calculate using mass emissions rate and gross output data (see § 63.10007(e)).
    OROR
    HCl and/or HF CEMSa. Install, certify, operate, and maintain the HCl or HF CEMSAppendix B of this subpart.
    b. Install, certify, operate, and maintain the diluent gas, flow rate, and/or moisture monitoring systemsPart 75 of this chapter and § 63.10010(a), (b), (c), and (d).
    c. Convert hourly emissions concentrations to 30 boiler operating day rolling average lb/MMBtu or lb/MWh emissions ratesMethod 19 F-factor methodology at appendix A-7 to part 60 of this chapter, or calculate using mass emissions rate and gross output data (see § 63.10007(e)).
    4. Mercury (Hg)Emissions Testinga. Select sampling ports location and the number of traverse pointsMethod 1 at appendix A-1 to part 60 of this chapter or Method 30B at Appendix A-8 for Method 30B point selection.
    b. Determine velocity and volumetric flow-rate of the stack gasMethod 2, 2A, 2C, 2F, 2G or 2H at appendix A-1 or A-2 to part 60 of this chapter.
    c. Determine oxygen and carbon dioxide concentrations of the stack gasMethod 3A or 3B at appendix A-1 to part 60 of this chapter, or ANSI/ASME PTC 19.10-1981.3
    d. Measure the moisture content of the stack gasMethod 4 at appendix A-3 to part 60 of this chapter.
    e. Measure the Hg emission concentrationMethod 30B at appendix A-8 to part 60 of this chapter, ASTM D6784,3 or Method 29 at appendix A-8 to part 60 of this chapter; for Method 29, you must report the front half and back half results separately.
    f. Convert emissions concentration to lb/TBtu or lb/GWh emission ratesMethod 19 F-factor methodology at appendix A-7 to part 60 of this chapter, or calculate using mass emissions rate and gross output data (see § 63.10007(e)).
    OROR
    Hg CEMSa. Install, certify, operate, and maintain the CEMSSections 3.2.1 and 5.1 of appendix A of this subpart.
    b. Install, certify, operate, and maintain the diluent gas, flow rate, and/or moisture monitoring systemsPart 75 of this chapter and § 63.10010(a), (b), (c), and (d).
    c. Convert hourly emissions concentrations to 30 boiler operating day rolling average lb/TBtu or lb/GWh emissions ratesSection 6 of appendix A to this subpart.
    OROR
    Sorbent trap monitoring systema. Install, certify, operate, and maintain the sorbent trap monitoring systemSections 3.2.2 and 5.2 of appendix A to this subpart.
    b. Install, operate, and maintain the diluent gas, flow rate, and/or moisture monitoring systemsPart 75 of this chapter and § 63.10010(a), (b), (c), and (d).
    c. Convert emissions concentrations to 30 boiler operating day rolling average lb/TBtu or lb/GWh emissions ratesSection 6 of appendix A to this subpart.
    OROR
    LEE testinga. Select sampling ports location and the number of traverse pointsSingle point located at the 10% centroidal area of the duct at a port location per Method 1 at appendix A-1 to part 60 of this chapter or Method 30B at Appendix A-8 for Method 30B point selection.
    b. Determine velocity and volumetric flow-rate of the stack gasMethod 2, 2A, 2C, 2F, 2G, or 2H at appendix A-1 or A-2 to part 60 of this chapter or flow monitoring system certified per appendix A of this subpart.
    c. Determine oxygen and carbon dioxide concentrations of the stack gasMethod 3A or 3B at appendix A-1 to part 60 of this chapter, or ANSI/ASME PTC 19.10-1981,3 or diluent gas monitoring systems certified according to part 75 of this chapter.
    Start Printed Page 56730
    d. Measure the moisture content of the stack gasMethod 4 at appendix A-3 to part 60 of this chapter, or moisture monitoring systems certified according to part 75 of this chapter.
    e. Measure the Hg emission concentrationMethod 30B at appendix A-8 to part 60 of this chapter; perform a 30 operating day test, with a maximum of 10 operating days per run (i.e., per pair of sorbent traps) or sorbent trap monitoring system or Hg CEMS certified per appendix A of this subpart.
    f. Convert emissions concentrations from the LEE test to lb/TBtu or lb/GWh emissions ratesMethod 19 F-factor methodology at appendix A-7 to part 60 of this chapter, or calculate using mass emissions rate and gross output data (see § 63.10007(e)).
    g. Convert average lb/TBtu or lb/GWh Hg emission rate to lb/year, if you are attempting to meet the 29.0 lb/year thresholdPotential maximum annual heat input in TBtu or potential maximum electricity generated in GWh.
    5. Sulfur dioxide (SO2)SO2 CEMSa. Install, certify, operate, and maintain the CEMSPart 75 of this chapter and § 63.10010(a) and (f).
    b. Install, operate, and maintain the diluent gas, flow rate, and/or moisture monitoring systemsPart 75 of this chapter and § 63.10010(a), (b), (c), and (d).
    c. Convert hourly emissions concentrations to 30 boiler operating day rolling average lb/MMBtu or lb/MWh emissions ratesMethod 19 F-factor methodology at appendix A-7 to part 60 of this chapter, or calculate using mass emissions rate and gross output data (see § 63.10007(e)).
    Start Amendment Part

    18. In appendix A to Part 63:

    End Amendment Part Start Amendment Part

    a. Revise section 12.4 in Method 303.

    End Amendment Part Start Amendment Part

    b. Revise section 2.0 in Method 308.

    End Amendment Part Start Amendment Part

    c. Remove and reserve section 7.2.2 in Method 308.

    End Amendment Part Start Amendment Part

    d. Revise sections 7.2.3.3, 8.1.2, 9.1, 11.3.2, and 12.1 in Method 308.

    End Amendment Part Start Amendment Part

    e. Add sections 12.5 and 13.0 in Method 308.

    End Amendment Part Start Amendment Part

    f. Revise sections 8.2.2.4 and 9.2.3 in Method 320.

    End Amendment Part Start Amendment Part

    g. Revise section 12.9 in Method 323.

    End Amendment Part Start Amendment Part

    h. Revise section 8.2.1.3, Figure 8.1. and section 8.2.3.2 in Method 325A.

    End Amendment Part Start Amendment Part

    i. Add sections 8.2.3.3 and 8.4.3 in Method 325A.

    End Amendment Part Start Amendment Part

    j. Revise sections 9.3.2, 9.13, 11.3.2.5, and 12.2.2 in Method 325B.

    End Amendment Part Start Amendment Part

    k. Remove sections 12.2.3 and 12.2.4 in Method 325B.

    End Amendment Part Start Amendment Part

    l. Revise table 17.1 in Method 325B.

    End Amendment Part

    The revisions and additions read as follows:

    Appendix A to Part 63—Test Methods

    * * * * *

    Method 303—Determination of Visible Emissions From By-Product Coke Oven Batteries

    * * * * *

    12.4 Average Duration of VE from Charging Operations. Use Equation 303-3 to calculate the daily 30-day rolling log average of seconds of visible emissions from the charging operation for each battery using these current day's observations and the 29 previous valid daily sets of observations.

    * * * * *

    Method 308—Procedure for Determination of Methanol Emission From Stationary Sources

    * * * * *

    2.0 Summary of Method

    A gas sample is extracted from the sampling point in the stack. The methanol is collected in deionized distilled water and adsorbed on silica gel. The sample is returned to the laboratory where the methanol in the water fraction is separated from other organic compounds with a gas chromatograph (GC) and is then measured by a flame ionization detector (FID). The fraction adsorbed on silica gel is extracted with deionized distilled water and is then separated and measured by GC/FID.

    * * * * *

    7.2.2 [Reserved]

    * * * * *

    7.2.3.3 Methanol Standards for Adsorbent Tube Samples. Prepare a series of methanol standards by first pipetting 10 ml of the methanol working standard into a 100-ml volumetric flask and diluting the contents to exactly 100 ml with deionized distilled water. This standard will contain 10 µg/ml of methanol. Pipette 5, 15, and 25 ml of this Start Printed Page 56731standard, respectively, into three 50-ml volumetric flasks. Dilute each solution to 50 ml with deionized distilled water. These standards will have 1, 3, and 5 µg/ml of methanol, respectively. Transfer all four standards into 40-ml glass vials capped with Teflon®-lined septa and store under refrigeration. Discard any excess solution.

    * * * * *

    8.1.2 Leak Check. A leak check before and after the sampling run is mandatory. The leak-check procedure is as follows:

    Temporarily attach a suitable (e.g., 0- to 40-ml/min) rotameter to the outlet of the DGM, and place a vacuum gauge at or near the probe inlet. Plug the probe inlet, pull a vacuum of at least 250 mm (10 inch) Hg or the highest vacuum experienced during the sampling run, and note the flow rate as indicated by the rotameter. A leakage rate in excess of 2 percent of the average sampling rate is acceptable.

    Note: Carefully release the probe inlet plug before turning off the pump.

    * * * * *

    9.1 Miscellaneous Quality Control Measures. The following quality control measures are required:

    SectionQuality control measureEffect
    8.1.2, 8.1.3, 10.1Sampling equipment leak check and calibrationEnsures accurate measurement of sample volume.
    10.2GC calibrationEnsures precision of GC analysis.
    13.0Methanol spike recovery checkVerifies all methanol in stack gas is being captured in impinge/adsorbent tube setup.
    * * * * *

    11.3.2 Desorption of Samples. Add 3 ml of deionized distilled water to each of the stoppered vials and shake or vibrate the vials for 30 minutes.

    * * * * *

    12.1 Nomenclature.

    Caf = Concentration of methanol in the front of the adsorbent tube, µg/ml.

    Cab = Concentration of methanol in the back of the adsorbent tube, µg/ml.

    Ci = Concentration of methanol in the impinger portion of the sample train,µg/ml.

    E = Mass emission rate of methanol, µg/hr (lb/hr).

    ms = Total mass of compound measured in impinger and on adsorbent with spiked train (mg).

    mu = Total mass of compound measured in impinger and on adsorbent with unspiked train (mg).

    mv = Mass per volume of spiked compound measured (mg/L).

    Mtot = Total mass of methanol collected in the sample train, µg.

    Pbar = Barometric pressure at the exit orifice of the DGM, mm Hg (in. Hg).

    Pstd = Standard absolute pressure, 760 mm Hg (29.92 in. Hg).

    Qstd = Dry volumetric stack gas flow rate corrected to standard conditions, dscm/hr (dscf/hr).

    R = fraction of spiked compound recovered

    s = theoretical concentration (ppm) of spiked target compound

    Tm = Average DGM absolute temperature, degrees K (°R).

    Tstd = Standard absolute temperature, 293 degrees K (528 °R).

    Vaf = Volume of front half adsorbent sample, ml.

    Vab = Volume of back half adsorbent sample, ml.

    Vi = Volume of impinger sample, ml.

    Vm = Dry gas volume as measured by the DGM, dry cubic meters (dcm), dry cubic feet (dcf).

    Vm(std) = Dry gas volume measured by the DGM, corrected to standard conditions, dry standard cubic meters (dscm), dry standard cubic feet (dscf).

    * * * * *

    12.5 Recovery Fraction (R)

    13.0 Method Performance

    Since a potential sample may contain a variety of compounds from various sources, a specific precision limit for the analysis of field samples is impractical. Precision in the range of 5 to 10 percent relative standard deviation (RSD) is typical for gas chromatographic techniques, but an experienced GC operator with a reliable instrument can readily achieve 5 percent RSD. For this method, the following combined GC/operator values are required.

    (a) Precision. Calibration standards must meet the requirements in section 10.2.1 or 10.2.2 as applicable.

    (b) Recovery. After developing an appropriate sampling and analytical system for the pollutants of interest, conduct the following spike recovery procedure at each sampling point where the method is being applied.

    i. Methanol Spike. Set up two identical sampling trains. Collocate the two sampling probes in the stack. The probes shall be placed in the same horizontal plane, where the first probe tip is 2.5 cm from the outside edge of the other. One of the sampling trains shall be designated the spiked train and the other the unspiked train. Spike methanol into the impinger, and onto the adsorbent tube in the spiked train prior to sampling. The total mass of methanol shall be 40 to 60 percent of the mass expected to be collected with the unspiked train. Sample the stack gas into the two trains simultaneously. Analyze the impingers and adsorbents from the two trains utilizing identical analytical procedures and instrumentation. Determine the fraction of spiked methanol recovered (R) by combining the amount recovered in the impinger and in the adsorbent tube, using the equations in section 12.5. Recovery values must fall in the range: 0.70 ≤ R ≤ 1.30. Report the R value in the test report.

    ii. [Reserved]

    * * * * *

    Method 320—Measurement of Vapor Phase Organic and Inorganic Emissions By Extractive Fourier Transform Infrared (FTIR) Spectroscopy

    * * * * *

    8.2.2.4 Determine the percent leak volume %VL for the signal integration time tSS and for ΔPmax, i.e., the larger of ΔPv or ΔPp, as follows:

    Start Printed Page 56732

    Where:

    50 = 100% divided by the leak-check time of 2 minutes.

    * * * * *

    9.2.3 Calculate the dilution ratio using the tracer gas as follows:

    DF = Dilution factor of the spike gas; this value shall be ≥10.

    SF6(dir) = SF6 (or tracer gas) concentration measured directly in undiluted spike gas.

    SF6(spk) = Diluted SF6 (or tracer gas) concentration measured in a spiked sample.

    Spikedir = Concentration of the analyte in the spike standard measured by filling the FTIR cell directly.

    CS = Expected concentration of the spiked samples.

    Unspike = Native concentration of analytes in unspiked samples.

    * * * * *

    Method 323—Measurment of Formaldehyde Emissions From Natural Gas-Fired Stationary Sources-Acetyl Acetone Derivitization Method

    * * * * *

    12.9 Formaldehyde Concentration Corrected to 15% Oxygen

    * * * * *

    Method 325A—Volatile Organic Compounds From Fugitive and Area Sources: Sampler Deployment and VOC Sample Collection

    * * * * *

    8.2.1.3 An extra sampler must be placed near known sources of VOCs if potential emission sources are within 50 meters (162 feet) of the boundary and the source or sources are located between two monitors. Measure the distance (x) between the two monitors and place another monitor approximately halfway between (x/2 ±10 percent) the two monitors. Only one extra sampler is required between two monitors to account for known sources of VOCs. For example, in Figure 8.1, the facility added three additional monitors (i.e., light shaded sampler locations), and in Figure 8.2, the facility added two additional monitors to provide sufficient coverage of all area sources.

    Start Printed Page 56733

    Figure 8.1. Facility with a Regular Shape Between 750 and 1,500 Acres in Area

    * * * * *

    8.2.3.2 For facilities with a monitoring perimeter length greater than or equal to 7,315 meters (24,000 feet), sampling locations are spaced 610 ± 76 meters (2,000 ± 250 feet) apart.

    8.2.3.3 Unless otherwise specified in an applicable regulation, permit or other requirement, for small disconnected subareas with known sources within 50 meters (162 feet) of the monitoring perimeter, sampling points need not be placed closer than 152 meters (500 feet) apart as long as a minimum of 3 monitoring locations are used for each subarea.

    * * * * *

    8.4.3 When extenuating circumstances do not permit safe deployment or retrieval of passive samplers (e.g., extreme weather, power failure), sampler placement or retrieval earlier or later than the prescribed schedule is allowed but must occur as soon as safe access to sampling sites is possible.

    * * * * *

    Method 325B—Volatile Organic Compounds From Fugitive and Area Sources: Sampler Preparation and Analysis

    * * * * *

    9.3.2 Field blanks must be shipped to the monitoring site with the sampling tubes and must be stored at the sampling location throughout the monitoring exercise. The field blanks must be installed under a protective hood/cover at the sampling location, but the long-term storage caps must remain in place throughout the monitoring period (see Method 325A). The field blanks are then shipped back to the laboratory in the same container as the sampled tubes. Collect at least two field blank samples per sampling period to ensure sample integrity associated with shipment, collection, and storage.

    * * * * *

    9.13 Routine CCV at the Start of a Sequence. Run CCV before each sequence of analyses and after every tenth sample to ensure that the previous multi-level calibration (see section 10.0) is still valid.

    * * * * *

    11.3.2.5 Whenever the thermal desorption—GC/MS analytical method is changed or major equipment maintenance is performed, you must conduct a new five-level calibration (see section 10.0). System calibration remains valid as long as results from subsequent CCV are within 30 percent of the most recent 5-point calibration (see section 9.13). Include relevant CCV data in the supporting information in the data report for each set of samples.

    * * * * *

    12.2.2 Determine the equivalent concentrations of compounds in atmospheres as follows. Correct target compound concentrations determined at the sampling site temperature and atmospheric pressure to standard conditions (25 °C and 760 mm mercury) using Equation 12.5.

    Where:

    mmeas = The mass of the compound as measured in the sorbent tube (µg).

    t = The exposure time (minutes).

    tss = The average temperature during the collection period at the sampling site (K).

    UNTP = The method defined diffusive uptake rate (sampling rate) (mL/min).

    Note: Diffusive uptake rates (UNTP) for common VOCs, using carbon sorbents packed into sorbent tubes of the dimensions specified in section 6.1, are listed in Table 12.1. Adjust analytical conditions to keep expected sampled masses within range (see sections 11.3.1.3 to 11.3.1.5). Best possible method detection limits are typically in the order of 0.1 ppb for 1,3-butadiene and 0.05 ppb for volatile aromatics such as benzene for 14-day monitoring. However, actual detection limits will depend upon the analytical conditions selected.

    * * * * *

    Table 17.1—Summary of GC/MS Analysis Quality Control Procedures

    ParameterFrequencyAcceptance criteriaCorrective action
    Bromofluorobenzene Instrument Tune Performance CheckDaily a prior to sample analysisEvaluation criteria presented in Section 9.5 and Table 9.2(1) Retune and or (2) Perform Maintenance.
    Five point calibration bracketing the expected sample concentrationFollowing any major change, repair or maintenance or if daily CCV does not meet method requirements. Recalibration not to exceed three months(1) Percent Deviation (%DEV) of response factors ±30% (2) Relative Retention Times (RRTs) for target peaks ±0.06 units from mean RRT(1) Repeat calibration sample analysis. (2) Repeat linearity check. (3) Prepare new calibration standards as necessary and repeat analysis.
    Calibration Verification (CCV Second source calibration verification check)Following the calibration curveThe response factor ±30% DEV from calibration curve average response factor(1) Repeat calibration check. (2) Repeat calibration curve.
    Laboratory Blank AnalysisDaily a following bromofluoro benzene and calibration check; prior to sample analysis(1) ≤0.2 ppbv per analyte or ≤3 times the LOD, whichever is greater (2) Internal Standard (IS) area response ±40% and IS Retention Time (RT) ±0.33 min. of most recent calibration check(1) Repeat analysis with new blank tube. (2) Check system for leaks, contamination. (3) Analyze additional blank.
    Blank Sorbent Tube CertificationOne tube analyzed for each batch of tubes cleaned or 10 percent of tubes whichever is greater<0.2 ppbv per VOC targeted compound or 3 times the LOD, whichever is greaterRe-clean all tubes in batch and reanalyze.
    Samples—Internal StandardsAll samplesIS area response ±40% and IS RT ±0.33 min. of most recent calibration validationFlag Data for possible invalidation.
    Start Printed Page 56734
    Field BlanksTwo per sampling periodNo greater than one-third of the measured target analyte or compliance limitFlag Data for possible invalidation due to high blank bias.
    a Every 24 hours.
    * * * * *
    End Supplemental Information

    Footnotes

    1.  Regarding emissions data collected during periods of startup or shutdown, see §§ 63.10020(b) and (c) and 63.10021(h).

    Back to Citation

    2.  See Tables 1 and 2 to this subpart for required sample volumes and/or sampling run times.

    3.  Incorporated by reference, see § 63.14.

    Back to Citation

    [FR Doc. 2018-24747 Filed 11-13-18; 8:45 am]

    BILLING CODE 6560-50-P

Document Information

Effective Date:
1/14/2019
Published:
11/14/2018
Department:
Environmental Protection Agency
Entry Type:
Rule
Action:
Final rule.
Document Number:
2018-24747
Dates:
The final rule is effective on January 14, 2019. The incorporation by reference materials listed in the rule are approved by the Director of the Federal Register as of January 14, 2019.
Pages:
56713-56734 (22 pages)
Docket Numbers:
EPA-HQ-OAR-2016-0510, FRL-9986-42-OAR
RINs:
2060-AS95: Revisions to Testing Regulations for Air Emission Sources
RIN Links:
https://www.federalregister.gov/regulations/2060-AS95/revisions-to-testing-regulations-for-air-emission-sources
Topics:
Air pollution control, Environmental protection, Incorporation by reference
PDF File:
2018-24747.pdf
Supporting Documents:
» Exit Filter Temperature rev1
» Filterable Particulate Matter Stack Test Methods: Performance Characteristics and Potential Improvements
» Docket Memo Eqn 12.4 and 12.5 in Method 325B
CFR: (3)
40 CFR 60.17
40 CFR 63.7
40 CFR 63.8