99-1075. Maine Yankee Atomic Power Company (Maine Yankee Atomic Power Station); Application of Exemption  

  • [Federal Register Volume 64, Number 11 (Tuesday, January 19, 1999)]
    [Notices]
    [Pages 2920-2921]
    From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
    [FR Doc No: 99-1075]
    
    
    -----------------------------------------------------------------------
    
    NUCLEAR REGULATORY COMMISSION
    
    [Docket No. 50-309]
    
    
    Maine Yankee Atomic Power Company (Maine Yankee Atomic Power 
    Station); Application of Exemption
    
    Exemption
    
    I
    
        Maine Yankee Atomic Power Company is the holder of Facility 
    Operating License No. DPR-36, which authorizes the licensee to possess 
    the Maine Yankee Atomic Power Station (MYAPS). The license states, 
    among other things, that the facility is subject to all the rules, 
    regulations, and orders of the U.S. Nuclear Regulatory Commission (the 
    Commission or NRC) now or hereafter in effect. The facility consists of 
    a pressurized-water reactor located at the licensee's site in Lincoln 
    County, Maine. The facility is permanently shut down and defueled, and 
    the licensee is no longer authorized to operate or place fuel in the 
    reactor.
    
    II
    
        Section 50.54(w) of 10 CFR Part 50 requires power reactor licensees 
    to maintain onsite property damage insurance coverage in the amount of 
    $1.06 billion. Section 140.11(a)(4) of 10 CFR Part 140 requires a 
    reactor with a rated capacity of 100,000 electrical kilowatts or more 
    to maintain liability insurance of $200 million and to participate in a 
    secondary insurance pool.
        NRC may grant exemptions from the requirements of 10 CFR Part 50 of 
    the regulations, which, pursuant to 10 CFR 50.12(a), (1) are authorized 
    by law, will not present an undue risk to public health and safety, and 
    are consistent with the common defense and security and (2) present 
    special circumstances. Special circumstances exist when (1) application 
    of the regulation in the particular circumstances would not serve the 
    underlying purpose of the rule or is not necessary to achieve the 
    underlying purpose of the rule (10 CFR 50.12(a)(2)(ii)) or (2) 
    compliance would result in undue hardship or costs that are 
    significantly in excess of those incurred by others similarly situated. 
    The underlying purpose of Section 50.54(w) is to provide sufficient 
    property damage insurance coverage to ensure funding for onsite post-
    accident recovery stabilization and decontamination costs in the 
    unlikely event of an accident at a nuclear power plant.
        NRC may grant exemptions from the requirements of 10 CFR Part 140 
    of the regulations, which, pursuant to 10 CFR 140.8, are authorized by 
    law and are otherwise in the public interest. The underlying purpose of 
    Section 140.11 is to provide sufficient liability insurance to ensure 
    funding for claims resulting from a nuclear incident or a precautionary 
    evacuation.
    
    III
    
        On January 20, 1998, the licensee requested exemption from the 
    financial protection requirement limits of 10 CFR 50.54(w) and 10 CFR 
    140.11. The licensee requested that the amount of insurance coverage it 
    must maintain be reduced to $50 million for onsite property damage and 
    $100 million for offsite financial protection. The licensee stated that 
    special circumstances exist because of the permanently shutdown and 
    defueled condition of MYAPS.
        The financial protection limits of 10 CFR 50.54(w) and 10 CFR 
    140.11 were established to require a licensee to maintain sufficient 
    insurance to cover the costs of a nuclear accident at an operating 
    reactor. Those costs were derived from the consequences of a release of 
    radioactive material from the reactor. Although the risk of an accident 
    at an operating reactor is very low, the consequences can be large. In 
    an operating plant, the high temperature and pressure of the reactor 
    coolant system, as well as the inventory of relatively short-lived 
    radionuclides, contribute to both the risk and consequences of an 
    accident. In a permanently shutdown and defueled reactor facility, the 
    reactor coolant system will never again be operated, thus eliminating 
    the possibility of accidents involving the reactor. A further reduction 
    in risk occurs because decay heat from the spent fuel decreases over 
    time. This reduction in decay heat reduces the amount of energy 
    available to heat up the spent fuel to a temperature that could 
    compromise the ability of the fuel cladding to retain fission products.
        Along with the reduction in risk, the consequences of a release 
    decline after a reactor permanently shuts down and defuels. The short-
    lived radionuclides contained in the spent fuel, particularly volatile 
    components such as iodine-131 and most of the noble gases, decay away, 
    thereby reducing the inventory of radioactive materials that are 
    readily dispersible and transportable in air.
        Although the risk and consequences of a radiological release 
    decline substantially after a plant permanently defuels its reactor, 
    they are not completely eliminated. There are potential onsite and 
    offsite radiological consequences that could be associated with the 
    onsite storage of the spent fuel in the spent fuel pool (SFP). In 
    addition, a site may contain a radioactive inventory of liquid 
    radwaste, activated reactor components, and contaminated structural 
    materials. For purposes of modifying the amount of insurance coverage 
    maintained by a power reactor licensee, the potential consequences, 
    despite very low risk, are an appropriate consideration.
        To determine the insurance coverage sufficient for a permanently 
    defueled facility, the cost of recovery from potential accident 
    scenarios must be evaluated. At MYAPS, spent fuel is the largest source 
    term on the site. The spent fuel is stored in the SFP, which uses water 
    to cool the fuel. Wet storage of spent fuel possesses inherently large 
    safety margins because of the simplicity and robustness of the SFP 
    design. The
    
    [[Page 2921]]
    
    design basis includes the ability to withstand an earthquake and to 
    retain sufficient water to adequately cool and shield the stored spent 
    fuel. In the MYAPS Defueled Safety Analysis Report, the licensee 
    specifically states that the SFP structure is designed to Seismic Class 
    I requirements and is capable of performing its intended safety 
    function under the licensee's design-basis hypothetical earthquake with 
    a 0.1-g peak ground acceleration. The floor and walls of the SFP are 
    constructed of 6-ft thick reinforced concrete and are completely lined 
    with \1/4\-inch steel plates. To add to the robustness of the design, 
    the pool is founded on bedrock and is embedded 12.5 feet below grade 
    level. Since the analyses used in designing the capability of 
    structures, systems, and components (SSCs) to perform their safety 
    function under a hypothetical earthquake have significant margin in 
    them, it is expected that an SSC built to withstand the hypothetical 
    design-basis earthquake actually will be able to withstand a larger 
    earthquake. Thus, the loss of coolant from the Maine Yankee SFP, which 
    partially or completely uncovers the fuel, is a beyond-design-basis 
    event with a very low probability of occurrence.
        The NRC staff has determined that a significant accident sequence 
    for a permanently shutdown reactor involves the loss of water from the 
    SFP and subsequent heatup of the fuel. If the decay heat is high 
    enough, oxidation of the zirconium fuel clad could become self-
    sustaining, resulting in a zirconium clad fire. Although the zirconium 
    clad fire may not be included in the design basis of the facility, the 
    NRC staff considers it among those accidents that are ``reasonably 
    conceivable'' and that should be considered in determining whether 
    there is undue risk to the public from a permanently shutdown reactor 
    facility. Analysis sponsored by the NRC in the late 1980s identified 
    approximately 2 years after shutdown as the critical decay time 
    necessary for pressurized-water reactor fuel to reach a decay power 
    below the minimum decay power for self-sustaining oxidation. Additional 
    NRC-sponsored analysis completed in 1997 identified 17 months as the 
    critical decay time for pressurized-water reactors. On December 6, 
    1998, Maine Yankee had been shut down for 24 months. Because of the 
    robust design and construction of the SFP and the fuel's having 
    exceeded the critical decay time for the representative pressurized-
    water reactor, the staff has determined that there is reasonable 
    assurance that rapid zirconium oxidation of the fuel cladding is no 
    longer possible. The staff has also concluded that the cost of 
    recovering from a loss of SFP water would be bounded by other accidents 
    that may occur at a permanently defueled site.
        In SECY 96-256, ``Changes to the Financial Protection Requirements 
    for Permanently Shutdown Nuclear Power Reactors, 10 CFR 50.54(w) and 10 
    CFR 140.11,'' dated December 17, 1996, the staff estimated the onsite 
    cleanup costs of accidents considered to be the most costly at a 
    permanently defueled site with spent fuel stored in the SFP. The staff 
    found that the onsite recovery costs for a fuel-handling accident could 
    range up to $24 million. The estimated onsite cleanup costs to recover 
    from the rupture of a large liquid radwaste storage tank could range up 
    to $50 million. The licensee's proposed level of $50 million for onsite 
    property insurance is sufficient to cover these estimated cleanup 
    costs.
        The offsite cleanup costs of the accident scenarios previously 
    discussed are estimated to be negligible in SECY 96-256. However, a 
    licensee's liability for offsite costs may be significant as a result 
    of lawsuits alleging damages from offsite releases. Experience at Three 
    Mile Island Unit 2 showed that significant judgments against a licensee 
    are possible despite negligible dose consequences from an offsite 
    release. An appropriate level of financial liability coverage is needed 
    to account for potential judgments and settlements and to protect the 
    Federal Government from indemnity claims. The licensee's proposed level 
    of $100 million in primary offsite liability coverage is sufficient for 
    this purpose.
        The staff has determined that participation in the secondary 
    insurance pool for offsite financial protection is not required for a 
    permanently shutdown and defueled plant after the time that air cooling 
    of the spent fuel is sufficient to maintain the integrity of the fuel 
    cladding. As previously noted, the staff finds that sufficient time has 
    elapsed to ensure the integrity of the MYAPS spent fuel cladding.
    
    IV
    
        The NRC staff has completed its review of the licensee's request to 
    reduce financial protection limits to $50 million for onsite property 
    insurance and $100 million for offsite liability insurance. On the 
    basis of its review, the NRC staff finds that the spent fuel stored in 
    MYAPS's SFP is no longer susceptible to rapid zirconium oxidation. The 
    requested reductions are consistent with SECY 96-256. The Commission 
    informed the staff in a staff requirements memorandum dated January 28, 
    1997, that it did not object to the insurance reductions recommended in 
    SECY 96-256. The licensee's proposed financial protection limits will 
    provide sufficient insurance to recover from limiting hypothetical 
    events, if they occur. Thus, the underlying purposes of the regulations 
    will not be adversely affected by the reductions in insurance coverage.
        Accordingly, the Commission has determined that, pursuant to 10 CFR 
    50.12(a), an exemption to reduce onsite property insurance to $50 
    million is authorized by law, will not present an undue risk to public 
    health and safety, and is consistent with the common defense and 
    security. Further, special circumstances are present, as set forth in 
    10 CFR 50.12(a)(2)(ii). Therefore the Commission hereby grants an 
    exemption from the requirements of 10 CFR 50.54(w).
        In addition, the Commission has determined that, pursuant to 10 CFR 
    140.8, an exemption to reduce primary offsite liability insurance to 
    $100 million, accompanied by withdrawal from the secondary insurance 
    pool for offsite liability insurance, is authorized by law and is in 
    the public interest. Therefore, the Commission hereby grants an 
    exemption from the requirements of 10 CFR 140.11(a)(4).
        Pursuant to 10 CFR 51.32, the Commission has determined that the 
    granting of these exemptions will not have a significant effect on the 
    quality of the human environment (63 FR 67943, printed December 9, 
    1998).
        These exemptions are effective upon issuance.
    
        Dated at Rockville, Maryland, this 7th day of January 1999.
    
        For the Nuclear Regulatory Commission.
    Samuel J. Collins,
    Director, Office of Nuclear Reactor Regulation.
    [FR Doc. 99-1075 Filed 1-15-99; 8:45 am]