2015-01420. Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 038
-
Start Preamble
AGENCY:
Food and Drug Administration, HHS.
ACTION:
Notice.
SUMMARY:
The Food and Drug Administration (FDA) is announcing a publication containing modifications the Agency is making to the list of standards FDA recognizes for use in premarket reviews (FDA Recognized Consensus Standards). This publication, entitled “Modifications to the List of Recognized Standards, Recognition List Number: 038” (Recognition List Number: 038), will assist manufacturers who elect to declare conformity with consensus standards to meet certain requirements for medical devices.
DATES:
Submit either electronic or written comments concerning this document at any time. See section VII of this document for the effective date of the recognition of standards announced in this document.
ADDRESSES:
An electronic copy of Recognition List Number: 038 is available on the Internet at http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/Standards/ucm123792.htm. See section VI of this document for electronic access to the searchable database for the current list of FDA recognized consensus standards, including Recognition List Number: 038 modifications and other standards related information.
Submit written requests for a single copy of the document entitled “Modifications to the List of Recognized Standards, Recognition List Number: 038” to the Division of Industry and Consumer Education, Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Bldg. 66, Rm. 4613, Silver Spring, MD 20993-0002. Send one self-addressed adhesive label to assist that office in processing your request, or fax your request to 301-847-8149.
Submit electronic comments on this document to http://www.regulations.gov. Submit written comments to the Division of Dockets Management (HFA-305), Food and Drug Administration, 5630 Fishers Lane, Rm. 1061, Rockville, MD 20852. Identify comments with the docket number found in brackets in the heading of this document.
Start Further InfoFOR FURTHER INFORMATION CONTACT:
Scott A. Colburn, Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Bldg. 66, Rm. 3632, Silver Spring, Start Printed Page 4275MD 20993, 301-796-6287, standards@cdrh.fda.gov.
End Further Info End Preamble Start Supplemental InformationSUPPLEMENTARY INFORMATION:
I. Background
Section 204 of the Food and Drug Administration Modernization Act of 1997 (FDAMA) (Pub. L. 105-115) amended section 514 of the Federal Food, Drug, and Cosmetic Act (the FD&C Act) (21 U.S.C. 360d). Amended section 514 allows FDA to recognize consensus standards developed by international and national organizations for use in satisfying portions of device premarket review submissions or other requirements.
In a notice published in the Federal Register of February 25, 1998 (63 FR 9561), FDA announced the availability of a guidance entitled “Recognition and Use of Consensus Standards.” The notice described how FDA would implement its standard recognition program and provided the initial list of recognized standards.
Modifications to the initial list of recognized standards, as published in the Federal Register, can be accessed at http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/Standards/ucm123792.htm.
These notices describe the addition, withdrawal, and revision of certain standards recognized by FDA. The Agency maintains hypertext markup language (HTML) and portable document format (PDF) versions of the list of FDA Recognized Consensus Standards. Both versions are publicly accessible at the Agency's Internet site. See section VI for electronic access information. Interested persons should review the supplementary information sheet for the standard to understand fully the extent to which FDA recognizes the standard.
II. Modifications to the List of Recognized Standards, Recognition List Number: 038
FDA is announcing the addition, withdrawal, correction, and revision of certain consensus standards the Agency will recognize for use in premarket submissions and other requirements for devices. FDA will incorporate these modifications in the list of FDA Recognized Consensus Standards in the Agency's searchable database. FDA will use the term “Recognition List Number: 038” to identify these current modifications.
In table 1, FDA describes the following modifications: (1) The withdrawal of standards and their replacement by others, if applicable; (2) the correction of errors made by FDA in listing previously recognized standards; and (3) the changes to the supplementary information sheets of recognized standards that describe revisions to the applicability of the standards.
In section III, FDA lists modifications the Agency is making that involve the initial addition of standards not previously recognized by FDA.
Table 1—Modifications to the List of Recognized Standards
Old recognition No. Replacement recognition No. Title of standard 1 Change A. Anesthesia 1-57 ASTM F1101-90 (Reapproved 2003) Standard Specification for Ventilators Intended for Use During Anesthesia Withdrawn. 1-69 ASTM F1464-93 (Reapproved 2005) Standard Specification for Oxygen Concentrators for Domiciliary Use Withdrawn. 1-70 ASTM F1246-91 (Reapproved 2005) Standard Specification for Electrically Powered Home Care Ventilators—Part 1: Positive-Pressure Ventilators and Ventilator Circuits Withdrawn. 1-94 ISO 8359 Second edition 1996-12-15, Oxygen concentrators for medical use—safety requirements [including amendment 1 (2012)] Withdrawn. See 1-102. B. Biocompatibility 2-143 2-213 ASTM F1904-14 Standard Practice for the Biological Responses to Particles in vivo Withdrawn and replaced with newer version. 2-144 2-214 ASTM F619-14 Standard Practice for Extraction of Medical Plastics. Withdrawn and replaced with newer version. C. Cardiovascular 3-88 ASTM F2514-08 (Reapproved 2014) Standard Guide for Finite Element Analysis (FEA) of Metallic Vascular Stents Subjected to Uniform Radial Loading Reaffirmation. 3-123 IEC 80601-2-30 Edition 1.1 2013-07, Medical electrical equipment—Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers Extent of recognition and Process impacted. D. Dental/ENT 4-117 ANSI/ADA Specification No. 12: 2002 (Reaffirmed 2008) Denture base polymers Withdrawn. 4-134 4-213 ISO 7494-1 Second edition 2011-08-15 Dentistry—Dental units—Part 1: General requirements and test methods Withdrawn and replaced with newer version. 4-135 4-214 ISO 10139-1 Second edition 2005-02-15, Dentistry—Soft lining materials for removable dentures—Part 1: Materials for short-term use [Including: Technical Corrigendum 1 (2006)] Withdrawn and replaced with newer version including technical corrigendum. 4-136 ASTM F2504-05 (Reapproved 2014) Standard Practice for Describing System Output of Implantable Middle Ear Hearing Devices Reaffirmation. Start Printed Page 4276 4-143 4-215 ANSI/ADA Standard No. 96: 2012 Dental Water-based Cements Withdrawn and replaced with newer version. 4-159 4-216 ANSI/IEEE ANSI C63.19-2011 American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids Withdrawn and replaced with newer version. 4-170 4-217 ANSI/ASA S3.36-2012 American National Standard Specification for a Manikin for Simulated in-situ Airborne Acoustic Measurements Withdrawn and replaced with newer version. 4-183 ANSI/ASA S3.2-2009 (Reaffirmed 2014) American National Standard Method for Measuring the Intelligibility of Speech over Communication Systems Reaffirmation. 4-185 ANSI/ASA S3.45-2009 (Reaffirmed 2014) American National Standard Procedures for Testing Basic Vestibular Function Reaffirmation. E. General I (Quality Systems/Risk Management (QS/RM)) 5-48 ANSI/ASQ Z1.9-2003 (R2013) Sampling Procedures and Tables for Inspection by Variables for Percent Nonconforming Reaffirmation. 5-57 ANSI/AAMI HE75:2009/(R)2013 Human factors engineering—Design of medical devices Reaffirmation. 5-62 ANSI/ASQ Z1.4-2003 (R2013) Sampling Procedures and Tables for Inspection by Attributes Reaffirmation. F. General Hospital/General Plastic Surgery (GH/GPS) 6-199 6-335 ASTM F2101-14 Standard Test Method for Evaluating the Bacterial Filtration Efficiency (BFE) of Medical Face Mask Materials, Using a Biological Aerosol of Staphylococcus aureus Withdrawn and replaced with newer version. 6-217 ASTM F1670/F1670M-08 (Reapproved 2014)1 Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood Reaffirmation. 6-228 6-336 IEC 60601-2-2 Edition 5.0 2009-02 Medical Electrical Equipment—Part 2-2: Particular Requirements for the Basic Safety and Essential Performance of High Frequency Surgical Equipment and High Frequency Surgical Accessories [Including: Technical Corrigendum 1 (2014)] Withdrawn and replaced with newer version including technical corrigendum. 6-231 6-337 ANSI/AAMI/IEC 60601-2-20:2009 Medical Electrical Equipment—Part 2-20: Particular Requirements for the Basic Safety and Essential Performance of Infant Transport Incubators [Including: Erratum (2012)] Withdrawn and replaced with newer version including erratum. G. In Vitro Diagnostics (IVD) 7-84 CEN 13640, Stability Testing of In Vitro Diagnostic Reagents Withdrawn. 7-162 CLSI POCT14-A (Formerly H49-A) Point-Of-Care Monitoring of Anticoagulation Therapy; Approved Guideline Withdrawn duplicate. See 7-112. 7-184 7-250 CLSI M40-A2 Quality Control of Microbiological Transport Systems; Approved Standard—Second Edition Withdrawn and replaced with newer version. H. Materials 8-111 8-380 ASTM F1160-14 Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate/Metallic Coatings Withdrawn and replaced with newer version. 8-124 8-381 ASTM F2052-14 Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment Withdrawn and replaced with newer version. 8-171 ASTM F1609-08 (Reapproved 2014) Standard Specification for Calcium Phosphate Coatings for Implantable Materials Reaffirmation. 8-198 8-382 ASTM F2102-13 Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants Withdrawn and replaced with newer version. 8-207 8-383 ASTM F1926/F1926M-14 Standard Test Method for Dissolution Testing of Calcium Phosphate Granules, Fabricated Forms, and Coatings Withdrawn and replaced with newer version. 8-340 8-384 ASTM F2026-14 Standard Specification for Polyetheretherketone (PEEK) Polymers for Surgical Implant Applications Withdrawn and replaced with newer version. 8-357 8-385 ASTM F648-14 Standard Specification for Ultra-High-Molecular-Weight Polyethylene Powder and Fabricated Form for Surgical Implants Withdrawn and replaced with newer version. Start Printed Page 4277 I. OB-GYN/Gastroenterology/Urology 9-6 9-95 IEC 60601-2-36 Edition 2.0 2014-04 Medical electrical equipment—Part 2-36: Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy Withdrawn and replaced with newer version. 9-45 ASTM F2528−06 (Reapproved 2014) Standard Test Methods for Enteral Feeding Devices with a Retention Balloon Reaffirmation. 9-62 9-96 IEC 60601-2-2 Edition 5.0 2009-02 Medical Electrical Equipment—Part 2-2: Particular Requirements for the Basic Safety and Essential Performance of High Frequency Surgical Equipment and High Frequency Surgical Accessories [Including: Technical Corrigendum 1 (2014)] Withdrawn and replaced with newer version including technical corrigendum. 9-74 9-97 ISO 13958 Third edition 2014-04-01 Concentrates for haemodialysis and related therapies Withdrawn and replaced with newer version. 9-76 9-98 ISO 13959 Third edition 2014-04-01 Water for haemodialysis and related therapies Withdrawn and replaced with newer version. 9-77 9-99 ISO 23500 Second edition 2014-04-01 Guidance for the preparation and quality management of fluids for haemodialysis and related therapies Withdrawn and replaced with newer version. 9-78 9-100 ISO 11663 Second edition 2014-04-01 Quality of dialysis fluid for haemodialysis and related therapies Withdrawn and replaced with a newer version. 9-79 9-101 ISO 26722 Second edition 2014-04-01 Water treatment equipment for haemodialysis applications and related therapies Withdrawn and replaced with a newer version. 9-82 9-102 ISO 4074 Second edition 2014-08-15 Natural rubber latex male condoms—Requirements and test methods Withdrawn and replaced with newer version. J. Ophthalmic 10-49 10-90 ISO 11979-9 First edition 2006-09-01 Ophthalmic implants—Intraocular lenses—Part 9: Multifocal intraocular lenses [Including: Amendment 1(2014)] Withdrawn and replaced with newer version including amendment. 10-50 10-91 ISO 11979-10 First edition 2006-08-15 Ophthalmic implants—Intraocular lenses—Part 10: Phakic intraocular lenses [Including: Amendment 1 (2014)] Withdrawn and replaced with newer version including amendment. 10-80 ISO 18369-2 Second edition 2012-12-01 Ophthalmic optics—Contact lenses—Part 2: Tolerances Extent of recognition and relevant guidance. K. Orthopedic 11-196 11-281 ASTM F1672-14 Standard Specification for Resurfacing Patellar Prosthesis Withdrawn and replaced newer version. 11-213 11-282 ASTM F1223-14 Standard Test Method for Determination of Total Knee Replacement Constraint Withdrawn and replaced with newer version. 11-260 11-283 ASTM F2943-14 Standard Guide for Presentation of End User Labeling Information for Musculoskeletal Implants Withdrawn and replaced with newer version. 11-263 11-284 ASTM F2028-14 Standard Test Methods for Dynamic Evaluation of Glenoid Loosening or Disassociation Withdrawn and replaced with newer version. L. Physical Medicine 16-189 16-193 ASME A18.1-2014 Safety Standard for Platform Lifts and Stairway Chairlifts Withdrawn and replaced with newer version. M. Radiology 12-181 12-284 NEMA NU 1-2012 Performance Measurements of Gamma Cameras. Withdrawn and replaced with newer version. 12-206 12-285 IEC 60601-2-1 Edition 3.1 2014-07 Medical electrical equipment—Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV Withdrawn and replaced with newer version. 12-230 NEMA XR 24-2008 (R2014) Primary User Controls for Interventional Angiography X-Ray Equipment Reaffirmation. N. Sterility 14-139 ISO 14644-1 First edition 1999-05-01 Cleanrooms and associated controlled environments—Part 1: Classification of air cleanliness Relevant guidance. Start Printed Page 4278 14-140 ISO 14644-2 First edition 2000-09-15 Cleanrooms and associated controlled environments—Part 2: Specifications for testing and monitoring to prove continued compliance with ISO 14644-1 Relevant guidance. 14-141 ISO 14644-4 First edition 2001-04-01 Cleanrooms and associated controlled environments—Part 4: Design, construction and start-up Relevant guidance. 14-165 ISO 14644-5 First edition 2004-08-15 Cleanrooms and associated controlled environments—Part 5: Operations Relevant guidance. 14-166 ISO 14644-7 First edition 2004-10-01 Cleanrooms and associated controlled environments—Part 7: Separative devices (clean air hoods, gloveboxes, isolators and mini-environments) Relevant guidance. 14-193 ANSI/AAMI/ISO 11607-1:2006/(R)2010, Packaging for terminally sterilized medical devices—Part 1: Requirements for materials, sterile barrier systems, and packaging systems Relevant guidance. 14-194 ANSI/AAMI/ISO 11607-2:2006/(R)2010, Packaging for terminally sterilized medical devices—Part 2: Validation requirements for forming, sealing and assembly processes Relevant guidance. 14-238 AAMI/ANSI/ISO 11140-5:2007/(R)2012, Sterilization of health care products—Chemical indicators—Part 5: Class 2 indicators for Bowie and Dick air removal test sheets and packs Relevant guidance. 14-242 ISO 14644-3 First edition 2005-12-15 Cleanrooms and associated controlled environments—Part 3: Test methods Relevant guidance. 14-243 ISO 14644-6 First edition Cleanrooms and associated controlled environments—Part 6: Vocabulary Relevant guidance. 14-274 ANSI/AAMI/ISO 15882:2008/(R)2013, Sterilization of health care products—Chemical indicators—Guidance for selection, use and interpretation of results Reaffirmation. 14-299 14-453 ASTM F2097-14 Standard Guide for Design and Evaluation of Primary Flexible Packaging for Medical Products Withdrawn and replaced with newer version. 14-355 14-454 ISO 11607-1 First edition 2006-04-15 Packaging for terminally sterilized medical devices—Part 1: Requirements for materials, sterile barrier systems and packaging systems [Including: Amendment 1 (2014)] Withdrawn and replaced with newer version including amendment. 14-356 14-455 ISO 11607-2 First edition 2006-04-15 Packaging for terminally sterilized medical devices—Part 2: Validation requirements for forming, sealing and assembly processes [Including: Amendment 1 (2014)] Withdrawn and replaced with newer version including amendment. 14-379 ISO 14644-8 Second edition 2013-02-15 Cleanrooms and associated controlled environments—Part 8: Classification of air cleanliness by chemical concentration (ACC) Relevant guidance. 14-389 ISO 14644-9 First edition 2012-08-15 Cleanrooms and associated controlled environments—Part 9: Classification of surface cleanliness by particle concentration Relevant guidance. 14-390 ISO 14644-10 First edition 2013-03-01 Cleanrooms and associated controlled environments—Part 10: Classification of surface cleanliness by chemical concentration Relevant guidance. 1 All standard titles in this table conform to the style requirements of the respective organizations. III. Listing of New Entries
In table 2, FDA provides the listing of new entries and consensus standards added as modifications to the list of recognized standards under Recognition List Number: 038.
Start Printed Page 4280Table 2—New Entries to the List of Recognized Standards
Recognition No. Title of standard 1 Reference No. and date A. Anesthesia 1-102 Medical electrical equipment—Part 2-69: Particular requirements for basic safety and essential performance of oxygen concentrator equipment ISO 80601-2-69 First edition 2014-07-15. B. Cardiovascular 3-133 International Standard-Cardiovascular implants—Cardiac valve prostheses—Part 3: Heart valve substitutes implanted by transcatheter techniques ISO 5840-3 First edition 2013-03-01. Start Printed Page 4279 C. Dental/Ear, Nose, and Throat 4-218 International Standard-Dentistry—Brackets and tubes for use in orthodontics ISO 27020 First edition 2010-12-15. 4-219 International Standard-Dentistry-Adhesive-Notched Edge Sheer Bond Strength Test ISO 29022 First edition 2013-06-01. D. General Hospital/General Plastic Surgery 6-338 Standard Specification for Radiation Attenuating Protective Gloves ASTM D7866-14a. 6-339 Standard Consumer Safety Specification for Full-Size Baby Cribs ASTM F1169-13. 6-340 Standard Consumer Safety Performance Specification for Commercial Cribs ASTM F2710-13. E. Nanotechnology 18-3 Technical Specification—Surface characterization of gold nanoparticles for nanomaterial specific toxicity screening: FT-IR method ISO/TS 14101 First edition 2012-11-01. F. Neurology 17-13 IEEE Recommended Practice for Neurofeedback Systems IEEE Std 2010-2012. G. Ophthalmics 10-92 American National Standard for Ophthalmics-Contact Lenses—Standard Terminology, Tolerances, Measurements and Physicochemical Properties ANSI Z80.20-2010 (Revision of ANSI Z80.20-2004) 12/06/2010. 10-93 American National Standard for Ophthalmics-Implantable Glaucoma Devices ANSI Z80.27-2014 (revision of ANSI Z80.27-2001 (R2011)) 01/27/2014. H. Orthopedic 11-285 Guide to Optimize Scan Sequences for Clinical Diagnostic Evaluation of Metal-on-Metal Hip Arthroplasty Devices using Magnetic Resonance Imaging ASTM F2978-13. 11-286 Guide For the Characterization of Wear from the Articulating Surfaces in Retrieved Metal-on-Metal and other Hard-on-Hard Prostheses ASTM F2979-14. I. Radiology 12-286 X-ray Equipment for Interventional Procedures—User Quality Control Mode NEMA XR-27-2013 with Amendment 1. 12-287 Supplemental Requirements for User Information and System Function Related to Dose in CT NEMA XR 28-2013. 12-288 Characterization of Phased Array Coils for Diagnostic Magnetic Resonance Images (MRI) NEMA MS 9-2008. J. Software/Informatics 13-70 Application of risk management for IT-networks incorporating medical devices—Part 2-5: Application guidance—Guidance on distributed alarm systems IEC TR 80001-2-5 2014. 13-71 Logical Observation Identifiers Names and Codes (LOINC) LOINC 2.48 2014-06-27. 13-72 Health informatics—Personal health device communication, Part 10425: Device Specialization—Continuous Glucose Monitor (CGM) IEEE Std 11073-10425-2014. K. Sterility 14-456 Packaging for terminally sterilized medical devices—Guidance on the application of ISO 11607-1 and ISO 11607-2 ISO/TS 16775 First edition 2014-05-15. 1 All standard titles in this table conform to the style requirements of the respective organizations. IV. List of Recognized Standards
FDA maintains the Agency's current list of FDA Recognized Consensus Standards in a searchable database that may be accessed directly at FDA's Internet site at http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfStandards/search.cfm. FDA will incorporate the modifications and revisions described in this notice into the database and, upon publication in the Federal Register, this recognition of consensus standards will be effective. FDA will announce additional modifications and revisions to the list of recognized consensus standards, as needed, in the Federal Register once a year, or more often if necessary. Beginning with Recognition List 033, FDA no longer announces minor revisions to the list of recognized consensus standards such as technical contact person, devices affected, processes affected, Code of Federal Regulations citations, and product codes.
V. Recommendation of Standards for Recognition by FDA
Any person may recommend consensus standards as candidates for recognition under section 514 of the FD&C Act by submitting such recommendations, with reasons for the recommendation to standards@cdrh.fda.gov. To be properly considered, such recommendations should contain, at a minimum, the following information: (1) Title of the standard, (2) any reference number and date, (3) name and address of the national or international standards development organization, (4) a proposed list of devices for which a declaration of conformity to this standard should routinely apply, and (5) a brief identification of the testing or performance or other characteristics of the device(s) that would be addressed by a declaration of conformity.
VI. Electronic Access
You may obtain a copy of “Guidance on the Recognition and Use of Consensus Standards” by using the Internet. The Center for Devices and Radiological Health (CDRH) maintains a site on the Internet for easy access to information including text, graphics, and files that you may download to a personal computer with access to the Internet. Updated on a regular basis, the CDRH home page, http://www.fda.gov/MedicalDevices,, includes a link to standards-related documents including the guidance and the current list of recognized standards. After publication in the Federal Register, this notice announcing “Modification to the List of Recognized Standards, Recognition List Number: 038” will be available at http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/Standards/ucm123792.htm. You may access “Guidance on the Recognition and Use of Consensus Standards,” and the searchable database for “FDA Recognized Consensus Standards” at http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/Standards.
VII. Submission of Comments and Effective Date
Interested persons may submit either electronic comments regarding this document to http://www.regulations.gov or written comments to the Division of Dockets Management (see ADDRESSES). It is only necessary to send one set of comments. Identify comments with the docket number found in brackets in the heading of this document. Received comments may be seen in the Division of Dockets Management between 9 a.m. and 4 p.m., Monday through Friday, and will be posted to the docket at http://www.regulations.gov. FDA will consider any comments received in determining whether to amend the current listing of modifications to the list of recognized standards, Recognition List Number: 038. These modifications to the list of recognized standards are effective upon publication of this notice in the Federal Register.
Start SignatureDated: January 22, 2015.
Leslie Kux,
Associate Commissioner for Policy.
[FR Doc. 2015-01420 Filed 1-26-15; 8:45 am]
BILLING CODE 4164-01-P
Document Information
- Published:
- 01/27/2015
- Department:
- Food and Drug Administration
- Entry Type:
- Notice
- Action:
- Notice.
- Document Number:
- 2015-01420
- Dates:
- Submit either electronic or written comments concerning this document at any time. See section VII of this document for the effective date of the recognition of standards announced in this document.
- Pages:
- 4274-4280 (7 pages)
- Docket Numbers:
- Docket No. FDA-2004-N-0451
- PDF File:
- 2015-01420.pdf
- Supporting Documents:
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 058
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 056
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 054
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 053
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 052
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 051
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 049
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 047
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 043
- » Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 041