DEPARTMENT OF TRANSPORTATION
Research and Special Programs Administration
[Docket No. RSPA-99-5143 (Notice No. 99-12]
Safety Advisory; DOT-3AL Cylinders in Carbon Dioxide Service;
Manufacturer Product Recall
AGENCY: Research and Special Programs Administration (RSPA), DOT.
ACTION: Safety advisory notice.
-----------------------------------------------------------------------
SUMMARY: RSPA was recently notified of certain cylinders that are
stamped incorrectly with the marking ``DOT-3AL3000''. The cylinders
should have been stamped ``DOT-3AL1800''. The manufacturer, Luxfer
(USA), has initiated a product recall of the affected cylinders which
are being used in carbon dioxide service. The purpose of this notice is
to advise owners, users, and requalifiers of the cylinders to follow
the precautionary measures outlined in this notice.
FOR FURTHER INFORMATION CONTACT: Mark Toughiry or Stanley Staniszewski,
Office of Hazardous Materials Technology, Research and Special Programs
Administration, U.S. Department of Transportation, 400 Seventh Street
SW, Washington DC 20590-001; telephone number (202)366-4545.
[[Page 56836]]
SUPPLEMENTARY INFORMATION: Recently, RSPA was notified by Luxfer (USA)
of the manufacture and sale of about 198 DOT-3AL specification
cylinders incorrectly marked with a service pressure of 3000 pounds per
square inch gauge (psig) instead of 1800 psig. The affected cylinders
were manufactured in February 1994 and shipped during the first half of
1994. The model information is shown as follows: Coo5, 5 pound Carbon
Dioxide (CO2) cylinders, Cast Code 787, Heat Treat Lot M98. Since
contacting its customers about cylinders in May 1999, Luxfer (USA) has
recovered seven cylinders in the following states: Maine, Pennsylvania,
New York and Virginia.
The 191 unaccounted-for cylinders are marked with serial numbers
X8321 through X8518. They may have been shipped to the following
companies: Manitowoc Beverage System, Inc., Hart & Price, Inc., Joe
Kirwan Company, Sanyo E & E Corporation, and Foxx Equipment Company.
If a hydrostatic pressure test is performed on one of these
cylinders to the prescribed 5/3 times the marked service pressure, the
cylinders are likely to fail at the 5,000 psig test pressure. RSPA is
not aware of any injuries that have occurred as a result of these
cylinders, but persons are advised that serious personal injury, death
or property damage could result from a cylinder failure. All persons
owning, using or having access to one of these cylinders should, as
soon as possible, contact: Lee Birch, Product Compliance and Safety
Manger, Luxfer (USA), 3016 Kansas Avenue, Riverside, CA 92507;
telephone number (909) 341-2214; fax (909) 328-1117; Internet web site
at www.luxfercylinders.com.
This safety advisory is available for review on the Internet by
accessing the HazMat Safety Homepage at http://hazmat.dot.gov.
Issued in Washington, D.C. on October 15, 1999.
Alan I. Roberts,
Associate Administrator for Hazardous Materials Safety.