C0-19723. Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures and Efficiency Standards for Commercial Air Conditioners and Heat Pumps  

  • Start Preamble Start Printed Page 63677 End Preamble Start Supplemental Information

    Correction

    In proposed rule document 00-19723 beginning on page 48828 in the issue of Wednesday, August 9, 2000, make the following correction:

    [Corrected]

    On page 48837 and 48838, in §431.271, Tables 1 and 2 should read as follows:

    TABLE 1.—Minimum Cooling Efficiency Levels

    ProductCategoryCooling capacitySubcategoryEfficiency Level 1
    Small Commercial Packaged Air Conditioning and Heating EquipmentAir Cooled, 3 Phase<65,000 Btu/hSplit System Single PackageSEER = 10.0 SEER = 9.7
    Air Cooled≥65,000 Btu/h and <135,000 Btu/hAllEER = 8.9
    Water Cooled Evaporatively Cooled, and Water-Source<65,000 Btu/h ≥65,000 Btu/h and <135,000 Btu/hAll AllEER = 9.3 EER = 10.5
    Large Commercial Packaged Air Conditioning and Heating EquipmentAir Cooled≥135,000 Btu/h and <240,000 Btu/hAllEER = 8.5
    Water-Cooled, and Evaporatively Cooled≥135,000 Btu/h and <240,000 Btu/hAllEER = 9.6
    Packaged Terminal Air Conditioners and Heat PumpsAll<7,000 Btu/h ≥7,000 Btu/h and ≤15,000 Btu/h >15,000 Btu/hAllEER = 8.88 EER = 10.0−(0.16 × capacity [in thousands of Btu/h at 95° outdoor dry-bulb temperature]) EER = 7.6
    1 All EER values must be rated at 95°F outdoor dry-bulb temperature for air-cooled products and evaporatively-cooled products and at 85°F entering water temperature for water-source and water-cooled products.
    Start Printed Page 63678

    TABLE 2.—MINIMUM HEATING EFFICIENCY LEVELS

    ProductCategoryCooling capacitySubcategoryEfficiency Level 2
    Small Commercial Packaged Air Conditioning and Heating EquipmentAir Cooled, 3 Phase<65,000 Btu/hSplit System Single PackageHSPF = 6.8 HSPF = 6.6
    Water-Source<135,000 Btu/hSplit System and Single PackageCOP = 3.8
    Air Cooled≥65,000 Btu/h and <135,000 Btu/hAllCOP = 3.0
    Large Commercial Packaged Air Conditioning and Heating EquipmentAir Cooled≥135,000 Btu/h and <240,000 Btu/hSplit System and Single PackageCOP = 2.9
    Packaged Terminal Heat PumpsAllAllAllCOP = 1.3+(0.16 × the applicable minimum cooling EER prescribed in Table 1—Minimum Cooling Efficiency Levels)
    2 All COP values must be rated at 47°F outdoor dry-bulb temperature for air-cooled products and evaporatively-cooled products and at 70°F entering water temperature for water-source products.
    End Supplemental Information Start Preamble End Preamble Start Supplemental Information

    Correction

    In rule document 00-25599 beginning on page 60101 in the issue of Tuesday, October 10, 2000, make the following corrections:

    [Corrected]

    1. On page 60102, in §52.1770 (c), in the table, in the section “Subchapter 2D—Air Pollution Control Requirements”, in the first line, the column for “State effective date” should read “1/15/98” and the column for “EPA approval date” should read “11/10/99”.

    2. On page 60103, in the same section of the table, in the last line, in the column for “State effective date”, “Annual Emissions Reporting” should read “1/15/98”. The column for “EPA approval date” should read “11/10/99” and the column for “Comments” should read “*”.

    End Supplemental Information Start Preamble End Preamble Start Supplemental Information

    Correction

    In notice document 00-25579 beginning on page 59463, in the issue of Thursday, October 5, 2000, make the following correction:

    On page 59463, in the third column, in the seventh line from the bottom, “ Sec. 3, SE 1/4 NW 1/2” should read “ Sec. 3, SE 1/4 NW 1/4 ”.

    End Supplemental Information

    [FR Doc. C0-19723 Filed 10-23-00; 8:45 am]

    BILLING CODE 1505-01-D

    [FR Doc. C0-25599 Filed 10-23-00; 8:45 am]

    BILLING CODE 1505-01-D

    [FR Doc. C0-25579 Filed 10-23-00; 8:45 am]

    BILLING CODE 1505-01-D

Document Information

Published:
10/24/2000
Department:
Land Management Bureau
Entry Type:
Correction
Document Number:
C0-19723
Pages:
63677-63678 (2 pages)
Docket Numbers:
Docket No. EE-RM/TP-99-460, NC-087-9939, FRL-6881-1, NM-930-1430-ET, NMNM 52408, NMNM 52409, NMNM 52410
RINs:
1904-AA97: Test Procedures for Commercial Air Conditioning Equipment
RIN Links:
https://www.federalregister.gov/regulations/1904-AA97/test-procedures-for-commercial-air-conditioning-equipment
PDF File:
c0-19723.pdf