[Federal Register Volume 61, Number 228 (Monday, November 25, 1996)]
[Rules and Regulations]
[Pages 59831-59832]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 96-30018]
=======================================================================
-----------------------------------------------------------------------
DEPARTMENT OF LABOR
Occupational Safety and Health Administration
29 CFR Part 1926
[Docket No. S-205]
RIN 1218-AA40
Safety Standards for Scaffolds Used in the Construction Industry
AGENCY: Occupational Safety and Health Administration, Department of
Labor.
ACTION: Final rule; Corrections, Partial stay.
-----------------------------------------------------------------------
SUMMARY: This document makes corrections to the final rule on Safety
Standards for Scaffolds Used in the Construction Industry, which was
published in the Federal Register on August 30, 1996 at 61 FR 46026.
The Agency is also issuing an administrative stay of the implementation
of final rule Sec. 1926.451(b)(2)(i) as it relates to roof bracket
scaffolds.
EFFECTIVE DATE: The corrections take effect November 25, 1996. The
administrative stay of Sec. 1926.451(b)(2)(i) is effective November 29,
1996.
FOR FURTHER INFORMATION CONTACT:
Ms. Bonnie Friedman, Occupational Safety and Health Administration,
Office of Information, Division of Consumer Affairs, Room N-3647, U.S.
Department of Labor, 200 Constitution Ave., NW., Washington, DC. 20210;
Telephone (202) 219-8151.
SUPPLEMENTARY INFORMATION: This document contains miscellaneous minor
corrections to the final rule for Safety Standards for Scaffolds Used
in the Construction Industry, which was published on August 30, 1996
(61 FR 46026).
This document also stays the implementation of the requirement in
final rule Sec. 1926.451(b)(2)(i) that roof bracket scaffolds be at
least 12 inches wide. The Murray-Black Co., a manufacturer of roof
bracket scaffolds, has filed a petition for review of final subpart L
in the United States Court of Appeals for the Sixth Circuit with
respect to the roof bracket width requirement. The Agency has received
information from Murray-Black and other manufacturers of roof bracket
scaffolds which indicates that most roof bracket scaffolds currently in
use are either 8 or 10 inches wide and that those roof brackets
function adequately. The original requirements of subpart L do not set
a minimum width for such scaffolds.
OSHA has concluded that the submissions by Murray-Black and other
scaffold manufacturers raise reasonable concerns regarding the minimum
width requirements for roof bracket scaffolds in final rule
Sec. 1926.451(b)(2)(i). The Agency believes that further rulemaking is
needed to determine what minimum width would be appropriate for roof
bracket scaffolds. Accordingly, OSHA is staying Sec. 1926.451(b)(2)(i),
as regards roof bracket scaffolds, and will act expeditiously to
initiate notice and comment rulemaking that addresses the minimum width
of roof bracket scaffolds.
Authority
This document was prepared under the direction of Joseph A. Dear,
Assistant Secretary of Labor for Occupational Safety and Health, U.S.
Department of Labor, 200 Constitution Ave, N.W., Washington, D.C.
20210.
Signed at Washington, D.C. this 20th day of November 1996.
Joseph A. Dear,
Assistant Secretary of Labor.
Accordingly, the publication of August 30, 1996 of Safety Standards
for Scaffolds Used in the Construction Industry (61 FR 46026) is hereby
corrected as set forth below.
Summary and Explanation--[Corrected]
1. On page 46085, the reference to 1926.451(e)(1) in the first full
paragraph in the middle column is corrected to read 1926.451(g)(1).
Sec. 1926.451 [Corrected]
2. On page 46107, in the first column, Sec. 1926.451(a)(2) is
corrected by removing the word ``either'' in the sixth line of the
paragraph.
3. On page 46108, in the first column, Sec. 1926.451(c)(2) is
corrected to read:
* * * * *
(c) * * *
(2) Supported scaffold poles, legs, posts, frames, and uprights
shall bear on base plates and mud sills or other adequate firm
foundation.
* * * * *
4. On page 46109, in the first column, Sec. 1926.451(d)(13) is
corrected to read:
* * * * *
(d) * * *
[[Page 59832]]
(13) Suspension scaffold power-operated hoists and manual hoists
shall be tested by a qualified testing laboratory.
* * * * *
5. On page 46110, the chart in Sec. 1926.451(f)(6) is corrected to
read:
Insulated Lines
------------------------------------------------------------------------
Voltage Minimum distance Alternatives
------------------------------------------------------------------------
Less than 300 volts.. 3 feet (0.9 m).......... .......................
300 volts to 50 kv... 10 feet (3.1 m)......... .......................
More than 50 kv...... 10 feet (3.1 m) plus 0.4 2 times the length of
inches (1.0 cm) for the line insulator,
each 1 kv over 50 kv. but never less than 10
feet (3.1 m).
------------------------------------------------------------------------
Uninsulated Lines
------------------------------------------------------------------------
Voltage Minimum distance Alternatives
------------------------------------------------------------------------
Less than 50 kv...... 10 feet (3.1 m)......... .......................
More than 50 kv...... 10 feet (3.1 m) plus 0.4 2 times the length of
inches (1.0 cm) for the line insulator,
each 1 kv over 50 kv. but never less than 10
feet (3.1 m).
------------------------------------------------------------------------
6. On page 46110, in the first column, the introductory language of
the Exception is corrected to read:
Exception to Paragraph (f)(6):
* * * * *
Sec. 1926.453 [Corrected]
7. On page 46117, in the first column, at the end of paragraph
(b)(2)(v) the following note is added:
Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of
this part (Sec. 1926.502(d)) provides that body belts are not
acceptable as part of a personal fall arrest system. The use of a
body belt in a tethering system or in a restraint system is
acceptable and is regulated under Sec. 1926.502(e).
* * * * *
Non-mandatory Appendix E--[Corrected]
8. On page 46124, a caption is added below the drawing to read:
HOISTS MUST BE ELECTRONICALLY ISOLATED FROM SCAFFOLD
* * * * *
PART 1926--[AMENDED]
9. The authority citation for subpart L of part 1926 continues to
read as follows:
Authority: Section 107, Contract Work Hours and Safety Standards
Act (Construction Safety Act) (40 U.S.C. 333); Secs. 4, 6, 8,
Occupational Safety and Health Act of 1970 (29 U.S.C. 653, 655,
657); Secretary of Labor's Order 1-90 (55 FR 9033); and 29 CFR Part
1911.
10. Section 1926.451(b)(2)(i) is amended by adding a note at the
end of the paragraph to read as follows:
Sec. 1926.451 General Requirements.
* * * * *
(b) * * *
(2) * * *
(i) * * *
Note to paragraph (b)(2)(i): pursuant to an administrative stay
effective November 29, 1996 and published in the Federal Register on
November 25, 1996, the requirement in paragraph (b)(2)(i) that roof
bracket scaffolds be at least 12 inches wide is stayed until
November 25, 1997 or until rulemaking regarding the minimum width of
roof bracket scaffolds has been completed, whichever is later.
* * * * *
[FR Doc. 96-30018 Filed 11-22-96; 8:45 am]