96-30018. Safety Standards for Scaffolds Used in the Construction Industry  

  • [Federal Register Volume 61, Number 228 (Monday, November 25, 1996)]
    [Rules and Regulations]
    [Pages 59831-59832]
    From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
    [FR Doc No: 96-30018]
    
    
    =======================================================================
    -----------------------------------------------------------------------
    
    DEPARTMENT OF LABOR
    
    Occupational Safety and Health Administration
    
    29 CFR Part 1926
    
    [Docket No. S-205]
    RIN 1218-AA40
    
    
    Safety Standards for Scaffolds Used in the Construction Industry
    
    AGENCY: Occupational Safety and Health Administration, Department of 
    Labor.
    
    ACTION: Final rule; Corrections, Partial stay.
    
    -----------------------------------------------------------------------
    
    SUMMARY: This document makes corrections to the final rule on Safety 
    Standards for Scaffolds Used in the Construction Industry, which was 
    published in the Federal Register on August 30, 1996 at 61 FR 46026. 
    The Agency is also issuing an administrative stay of the implementation 
    of final rule Sec. 1926.451(b)(2)(i) as it relates to roof bracket 
    scaffolds.
    
    EFFECTIVE DATE: The corrections take effect November 25, 1996. The 
    administrative stay of Sec. 1926.451(b)(2)(i) is effective November 29, 
    1996.
    
    FOR FURTHER INFORMATION CONTACT:
     Ms. Bonnie Friedman, Occupational Safety and Health Administration, 
    Office of Information, Division of Consumer Affairs, Room N-3647, U.S. 
    Department of Labor, 200 Constitution Ave., NW., Washington, DC. 20210; 
    Telephone (202) 219-8151.
    
    SUPPLEMENTARY INFORMATION: This document contains miscellaneous minor 
    corrections to the final rule for Safety Standards for Scaffolds Used 
    in the Construction Industry, which was published on August 30, 1996 
    (61 FR 46026).
        This document also stays the implementation of the requirement in 
    final rule Sec. 1926.451(b)(2)(i) that roof bracket scaffolds be at 
    least 12 inches wide. The Murray-Black Co., a manufacturer of roof 
    bracket scaffolds, has filed a petition for review of final subpart L 
    in the United States Court of Appeals for the Sixth Circuit with 
    respect to the roof bracket width requirement. The Agency has received 
    information from Murray-Black and other manufacturers of roof bracket 
    scaffolds which indicates that most roof bracket scaffolds currently in 
    use are either 8 or 10 inches wide and that those roof brackets 
    function adequately. The original requirements of subpart L do not set 
    a minimum width for such scaffolds.
        OSHA has concluded that the submissions by Murray-Black and other 
    scaffold manufacturers raise reasonable concerns regarding the minimum 
    width requirements for roof bracket scaffolds in final rule 
    Sec. 1926.451(b)(2)(i). The Agency believes that further rulemaking is 
    needed to determine what minimum width would be appropriate for roof 
    bracket scaffolds. Accordingly, OSHA is staying Sec. 1926.451(b)(2)(i), 
    as regards roof bracket scaffolds, and will act expeditiously to 
    initiate notice and comment rulemaking that addresses the minimum width 
    of roof bracket scaffolds.
    
    Authority
    
        This document was prepared under the direction of Joseph A. Dear, 
    Assistant Secretary of Labor for Occupational Safety and Health, U.S. 
    Department of Labor, 200 Constitution Ave, N.W., Washington, D.C. 
    20210.
    
        Signed at Washington, D.C. this 20th day of November 1996.
    Joseph A. Dear,
    Assistant Secretary of Labor.
    
        Accordingly, the publication of August 30, 1996 of Safety Standards 
    for Scaffolds Used in the Construction Industry (61 FR 46026) is hereby 
    corrected as set forth below.
    
    Summary and Explanation--[Corrected]
    
        1. On page 46085, the reference to 1926.451(e)(1) in the first full 
    paragraph in the middle column is corrected to read 1926.451(g)(1).
    
    
    Sec. 1926.451  [Corrected]
    
        2. On page 46107, in the first column, Sec. 1926.451(a)(2) is 
    corrected by removing the word ``either'' in the sixth line of the 
    paragraph.
        3. On page 46108, in the first column, Sec. 1926.451(c)(2) is 
    corrected to read:
    * * * * *
        (c) * * *
        (2) Supported scaffold poles, legs, posts, frames, and uprights 
    shall bear on base plates and mud sills or other adequate firm 
    foundation.
    * * * * *
        4. On page 46109, in the first column, Sec. 1926.451(d)(13) is 
    corrected to read:
    * * * * *
        (d) * * *
    
    [[Page 59832]]
    
        (13) Suspension scaffold power-operated hoists and manual hoists 
    shall be tested by a qualified testing laboratory.
    * * * * *
        5. On page 46110, the chart in Sec. 1926.451(f)(6) is corrected to 
    read:
    
                                 Insulated Lines                            
    ------------------------------------------------------------------------
           Voltage             Minimum distance            Alternatives     
    ------------------------------------------------------------------------
    Less than 300 volts..  3 feet (0.9 m)..........  .......................
    300 volts to 50 kv...  10 feet (3.1 m).........  .......................
    More than 50 kv......  10 feet (3.1 m) plus 0.4  2 times the length of  
                            inches (1.0 cm) for       the line insulator,   
                            each 1 kv over 50 kv.     but never less than 10
                                                      feet (3.1 m).         
    ------------------------------------------------------------------------
    
    
                                Uninsulated Lines                           
    ------------------------------------------------------------------------
           Voltage             Minimum distance            Alternatives     
    ------------------------------------------------------------------------
    Less than 50 kv......  10 feet (3.1 m).........  .......................
    More than 50 kv......  10 feet (3.1 m) plus 0.4  2 times the length of  
                            inches (1.0 cm) for       the line insulator,   
                            each 1 kv over 50 kv.     but never less than 10
                                                      feet (3.1 m).         
    ------------------------------------------------------------------------
    
        6. On page 46110, in the first column, the introductory language of 
    the Exception is corrected to read:
        Exception to Paragraph (f)(6):
    * * * * *
    
    
    Sec. 1926.453  [Corrected]
    
        7. On page 46117, in the first column, at the end of paragraph 
    (b)(2)(v) the following note is added:
    
        Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of 
    this part (Sec. 1926.502(d)) provides that body belts are not 
    acceptable as part of a personal fall arrest system. The use of a 
    body belt in a tethering system or in a restraint system is 
    acceptable and is regulated under Sec. 1926.502(e).
    * * * * *
    
    Non-mandatory Appendix E--[Corrected]
    
        8. On page 46124, a caption is added below the drawing to read:
    
    HOISTS MUST BE ELECTRONICALLY ISOLATED FROM SCAFFOLD
    
    * * * * *
    
    PART 1926--[AMENDED]
    
        9. The authority citation for subpart L of part 1926 continues to 
    read as follows:
    
        Authority: Section 107, Contract Work Hours and Safety Standards 
    Act (Construction Safety Act) (40 U.S.C. 333); Secs. 4, 6, 8, 
    Occupational Safety and Health Act of 1970 (29 U.S.C. 653, 655, 
    657); Secretary of Labor's Order 1-90 (55 FR 9033); and 29 CFR Part 
    1911.
    
        10. Section 1926.451(b)(2)(i) is amended by adding a note at the 
    end of the paragraph to read as follows:
    
    
    Sec. 1926.451  General Requirements.
    
    * * * * *
        (b)  * * *
        (2)  * * *
        (i)  * * *
    
        Note to paragraph (b)(2)(i): pursuant to an administrative stay 
    effective November 29, 1996 and published in the Federal Register on 
    November 25, 1996, the requirement in paragraph (b)(2)(i) that roof 
    bracket scaffolds be at least 12 inches wide is stayed until 
    November 25, 1997 or until rulemaking regarding the minimum width of 
    roof bracket scaffolds has been completed, whichever is later.
    * * * * *
    [FR Doc. 96-30018 Filed 11-22-96; 8:45 am]
    BILLING CODE 4510-26-M
    
    
    

Document Information

Effective Date:
11/25/1996
Published:
11/25/1996
Department:
Occupational Safety and Health Administration
Entry Type:
Rule
Action:
Final rule; Corrections, Partial stay.
Document Number:
96-30018
Dates:
The corrections take effect November 25, 1996. The administrative stay of Sec. 1926.451(b)(2)(i) is effective November 29, 1996.
Pages:
59831-59832 (2 pages)
Docket Numbers:
Docket No. S-205
RINs:
1218-AA40: Scaffolds (Part 1926) (Construction: Safer Scaffolds)
RIN Links:
https://www.federalregister.gov/regulations/1218-AA40/scaffolds-part-1926-construction-safer-scaffolds-
PDF File:
96-30018.pdf
CFR: (3)
29 CFR 1926.451(b)(2)(i)
29 CFR 1926.451
29 CFR 1926.453