C1-2013-28776. Energy Conservation Program: Energy Conservation Standards for Commercial and Industrial Electric Motors
-
Start Preamble
Correction
In proposed rule document 2013-28776 appearing on pages 73589-73681 in the issue of Friday, December 6, 2013, make the following corrections:
1. On page 73594, Table I.5 should appear as set forth below:
Table I.5—Proposed Energy Conservation Standards for Integral Brake Electric Motors and Non-Integral Brake Electric Motors (Compliance Starting December 19, 2015)
Motor horsepower/standard kilowatt equivalent Nominal full load efficiency (%) 4 Pole 6 Pole 8 Pole Enclosed Open Enclosed Open Enclosed Open 1/.75 85.5 85.5 82.5 82.5 75.5 75.5 1.5/1.1 86.5 86.5 87.5 86.5 78.5 77.0 2/1.5 86.5 86.5 88.5 87.5 84.0 86.5 3/2.2 89.5 89.5 89.5 88.5 85.5 87.5 5/3.7 89.5 89.5 89.5 89.5 86.5 88.5 7.5/5.5 91.7 91.0 91.0 90.2 86.5 89.5 10/7.5 91.7 91.7 91.0 91.7 89.5 90.2 15/11 92.4 93.0 91.7 91.7 89.5 90.2 20/15 93.0 93.0 91.7 92.4 90.2 91.0 25/18.5 93.6 93.6 93.0 93.0 90.2 91.0 30/22 93.6 94.1 93.0 93.6 91.7 91.7 2. On page 73627, Tables IV.10 and IV.11 should appear as follows:
Table IV.10—Efficiency Levels for Equipment Class Group 3
Representative unit EL 0 (EPACT 1992) (%) EL 1 (NEMA premium) (%) EL 2 (Best-in-market*) (%) EL 3 (Max-tech) (%) 5 hp 87.5 89.5 90.2 91.0 30 hp 92.4 93.6 94.1 94.5 75 hp 94.1 95.4 95.8 96.2 Start Printed Page 8904Table IV.11—Efficiency Levels for Equipment Class Group 2
Representative unit EL 1 (EPACT 1992) (%) EL 2 (NEMA premium) (%) EL 3 (Max-tech) (%) 5 hp 87.5 89.5 91.0 50 hp 92.4 93.6 94.5 3. On page 73634, in Table IV.14, In the second row, in the second column “1.61” Should read “51.61”.
Table IV.14—Product Conversion Costs for Efficiency Levels above NEMA Premium
Representative unit Per unit adder for 1 band above NEMA premium Per unit adder for 2 bands above NEMA premium 5 HP, Design B $11.06 $17.36 30 HP, Design B $32.89 $51.61 75 HP, Design B $66.18 $103.86 5 HP, Design C $10.68 $16.75 50 HP, Design C $60.59 $95.08 [AMENDED]4. On page 73679, in § 431.25(d), Table 4 should appear as set forth below:
Table 4—Nominal Full-Load Efficiencies of NEMA Design B General Purpose Electric Motors (Subtype I and II), Except Fire Pump Electric Motors
Motor horsepower/standard kilowatt equivalent Nominal full-load efficiency Open motors (number of poles) Enclosed motors (number of poles) 8 6 4 2 8 6 4 2 250/186 94.5 95.4 95.4 94.5 94.5 95.0 95.0 95.4 300/224 95.4 95.4 95.0 95.0 95.4 95.4 350/261 95.4 95.4 95.0 95.0 95.4 95.4 400/298 95.4 95.4 95.4 95.4 450/336 95.8 95.8 95.4 95.4 500/373 95.8 95.8 95.8 95.4 [FR Doc. C1-2013-28776 Filed 2-13-14; 8:45 am]
BILLING CODE 1505-01-D
Document Information
- Published:
- 02/14/2014
- Department:
- Energy Department
- Entry Type:
- Proposed Rule
- Document Number:
- C1-2013-28776
- Pages:
- 8903-8904 (2 pages)
- Docket Numbers:
- Docket Number EERE-2010-BT-STD-0027
- RINs:
- 1904-AC28: Energy Efficiency Standards for Certain Commercial and Industrial Electric Motors
- RIN Links:
- https://www.federalregister.gov/regulations/1904-AC28/energy-efficiency-standards-for-certain-commercial-and-industrial-electric-motors
- PDF File:
- c1-2013-28776.pdf
- Supporting Documents:
- » Request for Information: Collection, Transportation, Sorting, Processing and Second Life Applications for End-of-Life Lithium Ion Batteries
- » Request for Information: Grid Resilience and Innovation Partnerships Program
- » Agency Information Collection Activities; Proposals, Submissions, and Approvals
- » Worker Safety and Health Program
- » Agency Information Collection Activities; Proposals, Submissions, and Approvals
- » Application: NRG Power Marketing, LLC
- » Application: Command Power Corp.
- » Agency Information Collection Activities; Proposals, Submissions, and Approvals: Weatherization Assistance Program
- » Agency Information Collection Activities; Proposals, Submissions, and Approvals