C1-2024-01530. Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe Drinking Water Act; Analysis and Sampling Procedures  

  • Start Preamble

    Correction

    In rule document 2024–1530 beginning on page 5773 in the issue of Tuesday, January 30, 2024, make the following corrections:

    1. On page 5790, table “Alternative Testing Methods for Disinfectant Residuals Listed at 40 CFR 141.131(c)(1)” should have the column headings:

    ResidualMethodologySM 21st edition 1SM 22nd edition,28 SM 23rd edition,49 SM 24th edition 66ASTM 4Other

    2. On the same page, table “Alternative Testing Methods for Parameters Listed at 40 CFR 141.131(d)” should have column headings that appear as follows:

    ParameterMethodologySM 21st edition 1SM 22nd edition 28SM 23rd edition,49 SM 24th edition 66SM online 3EPAOther

    3. On the same page, table “Alternative Testing Methods for Contaminants Listed at 40 CFR 141.402(c)(2)” should have column headings that appear as follows:

    OrganismMethodologySM 20th edition 6SM 21st edition 1SM 22nd edition 28SM 23rd edition,49 SM 24th edition 66SM online 3Other

    4. On the same page, table “Alternative Testing Methods for Contaminants Listed at 40 CFR 141.852(a)(5)” should have column headings that appear as follows:

    OrganismMethodology categoryMethodSM 20th, 21st editions 16SM 22nd edition 28SM 23rd edition,49 SM 24th edition 66SM online 3

    5. On page 5792, table “Alternative Testing Methods for Contaminants Listed at 40 CFR 143.4(b)” should have column headings that appear as follows:

    ContaminantMethodologyEPA methodASTM 4SM 21st edition 1SM 22nd edition,28 SM 23rd edition,49 SM 24th edition 66SM online 3

    6. On the same page, table “Alternative Testing Methods for Contaminants Listed at 40 CFR 143.4(b), the entry for Chloride should read as follows:

    ChlorideSilver Nitrate TitrationD 512–04 B, 12 B4500–Cl B4500–Cl B
    Ion ChromatographyD 4327–11, –174110 B4110 B
    Potentiometric Titration4500–Cl D4500–Cl D
    Start Printed Page 7625

    7. On the same page, in the same table, the entry for Sulfate should read as follows:

    SulfateIon chromatographyD 4327–11, –174110 B4110 B
    Gravimetric with ignition of residue4500–SO42− C4500–SO42− C4500–SO42− C–97.
    Gravimetric with drying of residue4500–SO42− D4500–SO42− D4500–SO42− D–97.
    Turbidimetric methodD 516–07, 11, 164500–SO42− E4500–SO42− E4500–SO42− E–97.
    Automated methylthymol blue method4500–SO42− F4500–SO42− F4500–SO42− F–97.
    End Preamble

    [FR Doc. C1–2024–01530 Filed 2–2–24; 8:45 am]