2018-07410. Medicare Program; Reconciling National Coverage Determinations on Positron Emission Tomography (PET) Neuroimaging for Dementia  

  • Start Preamble

    AGENCY:

    Centers for Medicare & Medicaid Services (CMS), HHS.

    ACTION:

    Notice.

    SUMMARY:

    In accordance with the court order on July 19, 2016 (Kort v. Burwell), this notice provides further explanation on the National Coverage Determinations for positron emission tomography (PET) neuroimaging for dementia.

    Start Further Info

    FOR FURTHER INFORMATION CONTACT:

    Linda Gousis, (410) 786-8616.

    End Further Info End Preamble Start Supplemental Information

    SUPPLEMENTARY INFORMATION:

    I. Background

    On July 19, 2016, the United States District Court for the District of Columbia issued an order requiring the Secretary of Health and Human Services (HHS) to further explain one aspect of a National Coverage Determination (NCD) decision memorandum issued by the Centers for Medicare & Medicaid Services (CMS). Kort v. Burwell, 209 F.Supp.3d 98 (D.D.C. 2016). In particular, the court called for CMS to explain how its 2013 NCD denying coverage for a beta amyloid positron emission tomography scan (amyloid PET) [1] could be reconciled with an earlier 2004 NCD relating to fluorodeoxyglucose (FDG) positron emission tomography (PET) (FDG PET).[2] We issued the NCDs under our authority to interpret the “reasonable and necessary” statutory standard in section 1862(a)(1)(A) of the Social Security Act (the Act) as it applies to coverage of items and services in the Medicare program. In this notice, we describe the key differences between the two NCDs. We relied on the existing record in preparing this document.

    II. Provisions of the Notice

    In accordance with the Court's order, we explain why CMS covers one diagnostic test for specific patients, while covering the other only in the context of a clinical study (Kort, 115). Briefly, the differences arose from the type of assessment the test provided; predictive value of the test; and consensus panels' conclusions about the use of the tests.

    A. Summary of the NCDs

    The 2004 NCD for FDG PET resulted in narrow coverage of the diagnostic test for specific subpopulations of patients meeting narrowly defined criteria (CMS Start Printed Page 155732004, 32).[3] We determined that the “scan is reasonable and necessary in patients with documented cognitive decline of at least six months and a recently established diagnosis of dementia who meet diagnostic criteria for both Alzheimer's disease (AD) and fronto-temporal dementia (FTD), who have been evaluated for specific alternate neurodegenerative diseases or causative factors, and for whom the cause of the clinical symptoms remains uncertain” (CMS 2004, 3).

    The 2013 amyloid PET NCD resulted in non-coverage of amyloid PET for dementia and neurodegenerative disease; however, coverage was made available in the context of a clinical study. There, one amyloid PET scan per patient would be covered through coverage with evidence development (CED) pursuant to section 1862(a)(1)(E) of the Act (CMS 2013, 4). The diagnostic test is covered under certain research parameters “in two scenarios: (1) To exclude Alzheimer's disease (AD) in narrowly defined and clinically difficult differential diagnoses, such as AD versus frontotemporal dementia (FTD); and (2) to enrich clinical trials seeking better treatments or prevention strategies, by allowing for selection of patients on the basis of biological as well as clinical and epidemiological factors” (CMS 2013, 4).

    B. Kort v. Burwell Summary

    The plaintiffs in Kort were beneficiaries who exhibited symptoms of cognitive impairment but did not have a diagnosis for their illness. They wanted amyloid PET scans because they thought the scans would help their doctors make a differential diagnosis. The court determined that the amyloid PET NCD failed to adequately explain how the decision denying coverage for amyloid PET could be reconciled with the earlier decision approving coverage of FDG PET in certain contexts. The court noted, “[t]he similarities between FDG PET and BA scans are manifest. Both are diagnostic tests that involve the use of a PET scan and a radiopharmaceutical tracer. Both are indicated for use on overlapping patient populations exhibiting symptoms of cognitive impairment. And, although neither test can affirmatively diagnose a disease, both have diagnostic value as a tool for differentially diagnosing patients who exhibit symptoms associated with several different diseases” (Kort, 114-115). Without vacating the 2013 NCD, the Court remanded “the Decision Memo so that the agency can evaluate in the first instance whether its coverage decisions can be reconciled” (Kort, 115).

    C. Analytic Framework for Reviewing Clinical Evidence

    We evaluated the relevant clinical evidence to determine whether or not the evidence is sufficient to support a finding that an item or service is reasonable and necessary for the Medicare population, which consists largely of adults 65 years of age and older (CMS 2004, 13 and CMS 2013, 13). This process was discussed in the methodological principles for both NCDs. The critical appraisal of the evidence enables CMS to determine to what degree the agency is confident that the intervention will improve health outcomes for beneficiaries (CMS 2004, 13 and CMS 2013, 13).

    Specifically for diagnostic imaging tests, the overall assessment focuses on whether use of the test to guide patient management and treatment improves health outcomes (also referred to as clinical utility). Before appropriately reaching a consideration of outcomes, two fundamental properties of diagnostic tests need to be established: (1) the test accurately and reliably measures the intended analyte, factor, or component (also referred to as analytic validity); and (2) the test accurately and reliably identifies the condition or disorder of interest (also referred to as clinical validity). Outcomes such as change in patient management due to diagnostic tests and accuracy, sensitivity, and specificity are also of interest to CMS (CMS 2004, 14 and CMS 2013, 30).

    D. Review of the Clinical Evidence for FDG and Amyloid PET

    While both diagnostic tests use a PET scan, there is a distinction in the tracers used for the scans: FDG provides a physiologic (functional) assessment of the brain since it highlights glucose metabolism; meanwhile, beta amyloid tracers such as florbetapir (Amyvid®) and flutemetamol (Vizamyl®) provide a molecular (anatomic) assessment since they bind to amyloid β plaques (CMS 2004, 5 and CMS 2013, 11). In both coverage analysis, we focused on whether the PET scans can accurately and reliably identify dementias, including AD, and whether use of the scans to guide management and treatment improves meaningful health outcomes (CMS 2004, 14 and CMS 2013, 14). We focused on these because numerous mechanism of action studies have shown that PET scans can accurately and reliably detect radionuclide tracers that tag nitrogen, oxygen, glucose, and amyloid.[4]

    Ultimately, we determined that evidence for FDG PET for differential diagnosis of dementias was more compelling and substantiated than for amyloid PET when the same analytic framework was applied to these diagnostic imaging tests. There were several reasons for CMS finding FDG PET more compelling. The ability of the FDG PET test to accurately and reliably identify the disorder of interest is better established and accepted than for molecular PET scans, such as beta amyloid (CMS 2004, 8). Since the 1980s, functional assessment of the brain using one of a number of tracers, such as ones for blood flow, oxygen utilization, and glucose metabolism, has been used to diagnose dementia. Among these, FDG is a glucose analog and behaves similar to glucose in the cell. Glucose metabolism may be viewed as an indicator of cell activity. Used as a PET tracer, FDG will indicate the cell activity. In the brain, function as shown by cell activity (glucose metabolism or FDG tagging) may be used to differentiate causes of dementia (CMS 2004, 7). For example, in frontal lobe dementia, imaging tests have shown marked hypometabolism (darker areas) of the frontal or temporal lobes with sparing of parietal lobes. In patients with Alzheimer's disease, there is typically hypometabolism bilaterally in the temporal and parietal lobes (CMS 2004, 5, 7, and 33). Additionally, “the presumed higher specificity of FDG PET for detecting metabolic patterns correlated with FTD could decrease the number of false positive results for AD and consequently increase the number of true positives for FTD to inform Start Printed Page 15574patient management and caregiver counseling” (CMS 2004, 35).

    In contrast to the evidence supporting use of FDG PET, there were uncertainties regarding the use of amyloid PET. The presence or absence of amyloid in the brain has been considered in diagnosis of AD, but it is not diagnostic because some normal individuals also have amyloid plaques (CMS 2013, 10). Amyloid tracers bind to and statically mark amyloid plaque providing an anatomic or structural assessment (location and concentration) but do not provide information on cell activity or brain function. This is an inherent limitation of anatomic assessments compared to functional assessments because the hallmark of dementia is an abnormal decline in cognitive function (CMS 2013, 7). Thus, the premise that the test accurately and reliably identifies the disorder is reduced in amyloid imaging compared to functional imaging, such as FDG, due to the different mechanisms of action. Additionally, the ability of amyloid PET scans to diagnose AD is inherently reduced by the pathophysiologic characteristics of AD since the presence extracellular amyloid β is only one of two specific findings required for the diagnosis of AD. The second key factor is the presence of intracellular neurofibrillary tangles (NFTs) consisting of abnormal tau proteins. Amyloid tracers do not show the presence of NFTs or abnormal tau proteins, which are not detected by any commercially available radionuclide tracer (CMS 2013, 10). In addition, findings based on postmortem investigation and studies (pathophysiologic alternations in brain biopsies) may not directly translate to factors that may be used to make a clinical diagnosis of patients with dementia.

    The FDG PET NCD acknowledged that AD-type physiology may be present in normal individuals with normal cognitive function; therefore, a positive amyloid PET scan does not necessarily mean the individual has AD (CMS 2004, 5). As subsequently noted in the amyloid PET decision memo nine years later, “[A]myloid plaques are seen in other diseases, such as dementia with Lewy bodies, cerebral amyloid angiopathy, Parkinson's disease, Huntington's disease, and inclusion body myositis. Amyloid plaques can also be detected in cognitively normal older adults. Autopsy studies demonstrate that approximately 33% of older individuals (20-65% depending on age) who are cognitively normal have amyloid accumulation at levels consistent with AD pathology (Hulette 1998, Price 1999, Knopman 2003, Rowe 2010)” (CMS 2013, 10).

    The reliability of test is a necessary component for determining health outcomes or clinical utility. The foundation of clinical utility for functional PET scans, like FDG PET, is better established than anatomic PET scans, like amyloid PET. While direct, high quality evidence on clinical utility of FDG PET for dementia was not found in published literature at the time of the 2004 decision, there were related studies that showed clinical utility of FDG PET for other treatable causes of cognitive impairment or dementia such as cerebrovascular disease, certain inherited diseases, and metabolic conditions that could possibly be diagnosed with FDG PET, and then treated with proven therapies to improve health outcomes (CMS 2004, 32, 37). At the time of the amyloid PET NCD, there was no published evidence of clinical utility similar to what was reviewed for FDG PET, and there were no related studies suggesting that amyloid PET would be helpful in the differential diagnosis of AD and FTD (CMS 2013, 14). Further, because amyloid PET does not specifically diagnose other conditions, the clinical utility or improved health outcomes associated with other diseases is not applicable.

    Since the mid-2000s, a number of clinical trials of different therapies that target amyloid have failed to produce results of improvement in health outcomes (CMS 2013, 61).[5] FDG PET did not have the same negative trials at the time of our 2004 decision.

    E. Determining the Predictive Value of Amyloid PET Compared to FDG PET

    We did not have the same concerns regarding false positives using FDG PET to differentially diagnose AD as we did with amyloid PET. The predictive value of the amyloid PET scan cannot be based solely on its capability to “rule out” AD, because there is also the risk of positively diagnosing patients with Alzheimer's when they do not have it. Conversely, for a patient faced with the possibility of having Alzheimer's, a negative amyloid PET result could be reassuring (CMS 2013, 52-53). However, such reassurance would not change clinical management because the patient may still have AD. If a clinician did not have “a convincing clinical picture [of AD], work up to exclude other diagnosable and potentially treatable diseases should proceed anyway (as it would if an amyloid scan were negative). The unavailability of an amyloid scan does not change that logic” (CMS 2013, 52).

    At the same time, the amyloid PET scan portends great risk because there is no evidence for what a positive scan means in specific patients since they can have amyloid plaques but not have AD. At the Medicare Evidence Development & Coverage Advisory Committee (MEDCAC) meeting held specifically on amyloid PET on January 30, 2013, one expert speaker mentioned that he believed that a patient with mild cognitive impairment (MCI) and a positive amyloid PET scan had Alzheimer's disease and that many other experts agreed with him (MEDCAC 2013, 31, 53).[6] However, no published clinical trials, studies, consensus publications, or further MEDCAC discussions identified whether, for amyloid PET, “objectively-defined subpopulations of patients with cognitive impairment for which the scan (alone or combined with other tests) may be more or less appropriate. Yet there are many subtypes of MCI, and some (e.g., amnestic MCI) may be more relevant than others. Furthermore, there is evidence that the same level of amyloid burden detected by a scan may mean something very different in say, a 66 year-old compared to an 86 year-old (e.g., Le Couteur 2013, Laforce 2011). Yet the [Amyloid Imaging Task Force] AIT is silent about such potentially important distinctions” (CMS 2013, 33). (The AIT was a consensus panel that developed recommendations for use of amyloid PET.)

    We concluded in the amyloid PET NCD that “widespread clinical use of the scan both in many types of patients with unexplained MCI, and to make a positive diagnosis of Alzheimer's disease (despite insufficient evidence on Start Printed Page 15575the clinical meaning of a positive scan) has great potential to lead to over-diagnosis of Alzheimer's disease. Such misdiagnosis of Alzheimer's disease portends real harm to our beneficiaries (La Couteur 2013), and this must be considered in our coverage decision” (CMS 2013, 33).

    “False positive” test results, widely considered by radiologists as the bane of diagnostic imaging, are of special concern for amyloid PET. The following are scenarios that contrast the impacts of negative, positive, and false positive test results. For example, if a patient were to get a computed tomography (CT) study of the chest, abdomen, and pelvis to “rule out” cancer, and if the CT study were negative, that indeed would be reassuring to the patient. However, if the study were positive for an enlarged lymph node, liver lesion, or some questionable pulmonary nodule, these findings could be followed up by biopsy, surgical resection, or assessing for progression of disease on a close follow-up CT. In contrast, a completely different clinical scenario follows amyloid PET. Those options to further explore findings common for other “positive” diagnostic tests do not exist. Providers cannot do a biopsy, resection, or close follow up of amyloid imaging after a positive amyloid scan.

    Concern about false positive test results was not a major factor in the 2004 decision memorandum on FDG PET. Based off of an external technical assessment that helped inform the 2004 decision memorandum, we concluded that “FDG-PET testing would reduce the number of false positive results” (CMS 2004, 16). FDG PET has the ability to diagnose patients with disease (dementias, not only Alzheimer's) since it is a functional test and measures glucose metabolism (activity) as noted earlier. Based on the patterns of uptake (cellular function indicating activity), a differential diagnosis between FTD (characteristic hypometabolism in the frontal lobe of the brain) versus AD (characteristic hypometabolism in temporal and parietal lobes of the brain) versus normal patterns (no hypometabolism) may be made. In our FDG PET decision, we noted, “Patients with FTD generally tend to show bifrontal and bitemporal hypoperfusion in single photon emission computerized tomography (SPECT) or glucose hypometabolism in FDG PET scans. In contrast, temporoparietal defects are predominant in AD” (CMS 2004, 7).

    In contrast, the false positive results were a greater concern with amyloid PET (CMS 2013, 48-50), since amyloid plaques may be present in many individuals with normal cognitive function. As noted earlier, the presence of amyloid (positive test) by itself does not diagnose AD since the diagnosis of AD is based on the presence of both amyloid and tau proteins on autopsy. A positive amyloid PET does not allow a differential diagnosis between FTD versus AD versus an individual with normal cognitive function since amyloid is a structural component and does not indicate function.

    F. Expert Consensus in Making Evidence-based NCDs

    Two expert panels, in 2002, the Medicare Coverage Advisory Committee (MCAC) [7] Diagnostic Imaging Panel,[8] and, in 2004, the National Institute on Aging (NIA) agreed on a narrow conditioned clinical use for the FDG PET scan (MCAC-DIP 2002, 122, 196-197 and CMS 2004, 35). The expert panel convened by NIA believed the existing evidence warranted use of FDG-PET for a limited number of cases including differential diagnosis of AD and FTD (NIA 2004, 32, 35, 45, 48, and 51-52). For these reasons, in 2004 we had confidence in the plausibility of downstream health outcomes for a narrow indication for FDG PET for differential diagnosis of AD and FTD.

    In contrast to the uniform consensus for FDG PET, in 2013, two expert panels, the AIT [9] and MEDCAC,[10] manifestly disagreed about the clinical use of the amyloid PET scan (CMS 2013, 33 and MEDCAC 2013, 55). While the AIT noted amyloid imaging may be appropriate in progressive unexplained or unclear clinical presentations (Johnson 2013, e6), the MEDCAC did not find sufficient evidence for CMS to support outright coverage of amyloid PET (MEDCAC 2013, 248, 250). This different degree of consensus between 2004 and 2013 was a contributing factor in our decisions. However, our evidence-based approach to coverage determinations does not rely on consensus alone. As explained in the 2013 NCD, “two credible expert panels—the AIT and the MEDCAC—produced differing consensuses. That's why, in the well-established process of scientific evaluation, evidence must be evaluated to determine the strength of the consensus opinion” (CMS 2013, 33). At the time the amyloid PET NCD was finalized, there was no evidence to support or refute the consensus opinions. CED for amyloid PET supported the needed development of evidence for future evaluation. Therefore, based on the evidence reviewed as described above and the conclusions of the expert panels, we came to differing conclusions because the evidence for FDG PET for a narrowly defined patient population was better established than for amyloid PET.

    G. Summary

    As required by the court order that accompanied the Kort opinion, this document further explains why we reached different conclusions with respect to section 1862(a)(1)(A) of the Act in the NCDs for FDG PET and amyloid PET. Both decisions were based on the available evidence according to our analytic framework described herein. Based on that evidence, we created narrow coverage for a small patient population with extensive patient eligibility criteria and provider requirements for FDG PET. For amyloid PET, the totality of the evidence available was not sufficient to demonstrate that the test produced diagnostic value as a tool for differentially diagnosing patients who exhibit symptoms associated with AD or FTD. Therefore, we established coverage for amyloid PET in the context of a clinical study setting with patient and provider eligibility criteria under the authority of section 1862(a)(1)(E) of the Act.

    III. Collection of Information Requirements

    This document does not impose information collection requirements, that is, reporting, recordkeeping or third-party disclosure requirements. Consequently, there is no need for review by the Office of Management and Budget under the authority of the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.).

    Start Signature
    Start Printed Page 15576

    Dated: March 16, 2018.

    Seema Verma,

    Administrator, Centers for Medicare & Medicaid Services.

    Dated: April 5, 2018.

    Alex M. Azar II,

    Secretary, Department of Health and Human Services.

    End Signature End Supplemental Information

    Footnotes

    1.  CMS, Decision Memo for Beta Amyloid Positron Emission Tomography in Dementia and Neurodegenerative Disease (CAG-00431N); 2013 September 27. Available from: https://www.cms.gov/​medicare-coverage-database/​details/​nca-decision-memo.aspx?​NCAId=​265 (accessed on June 22, 2017). Note that amyloid PET is referred to in the 2013 NCD as “βA PET” or “amyloid PET” interchangeably. In this document, we are using “amyloid PET”; however, quotes may refer to it by the similar terms.

    Back to Citation

    2.  CMS, Decision Memo for Positron Emission Tomography (FDG) and Other Neuroimaging Devices for Suspected Dementia (CAG-00088R); 2014 September 15. Available from: https://www.cms.gov/​medicare-coverage-database/​details/​nca-decision-memo.aspx?​NCAId=​104 (accessed on June 22, 2017).

    Back to Citation

    3.  In this document, page numbers for the decision memorandum citations are based off of the page number at the bottom of the page on the PDF version which is available for download from web page provided in the previous footnotes for this document. Click on the “Need a PDF?” icon on the right side of the screen to obtain a PDF.

    Back to Citation

    4.  Petersen et al. Practice parameter: Early detection of dementia: Mild cognitive impairment (an evidence-based review), Report of the Quality Standards Subcommittee of the American Academy of Neurology. Neurology. May 2001; Neuroimaging in the Diagnosis of Alzheimer's Disease and Dementia. Expert panel convened by the Neuroscience and Neuropsychology of Aging Program, National Institute on Aging (NIA), HHS. April 5, 2004. https://www.cms.gov/​Medicare/​Coverage/​DeterminationProcess/​downloads/​id104d.pdf (accessed on August 9, 2017); and D Matchar, S Kulasingam, B Huntington, M Patwardhan, L Mann. Technology Assessment: Positron emission tomography, single photon emission computed tomography, computed tomography, functional magnetic resonance imaging, and magnetic resonance spectroscopy for the diagnosis and management of Alzheimer's disease. Duke Center for Clinical Health Policy Research and Evidence Practice Center. December 2001. https://www.cms.gov/​Medicare/​Coverage/​DeterminationProcess/​downloads/​id9TA.pdf (accessed August 9, 2017). (CMS 2004, 43 and 46)

    Back to Citation

    5.  See also Peterson RC. Early Diagnosis of Alzheimer's Disease: Is MCI Too Late? Current Alzheimer Research. 2009; 6(4):329; Petersen RC, Smith G, Waring S, et al. Mild cognitive impairment: clinical characterization and outcome. Archives of Neurology. 1999;56:303-8; National Institute on Aging (NIA) and the Reagan Institute. Consensus recommendations for the postmortem diagnosis of Alzheimer's disease. The National Institute on Aging, and Reagan Institute Working Group on Diagnostic Criteria for the Neuropathological Assessment of Alzheimer's Disease. Neurobiology of Aging. 1997 Jul-Aug;18(4 Suppl):S1-2; and Technology Evaluation Center (TEC), Blue Cross Blue Shield. Beta Amyloid Imaging with Positron Emission Tomography (PET) for Evaluation of Suspected Alzheimer's Disease or Other Causes of Cognitive Decline. 2013 February;27(5).

    Back to Citation

    6.  Medicare Evidence Development & Coverage Advisory Committee (MEDCAC), Meeting: Beta Amyloid Positron Emission Tomography (PET) in Dementia and Neurodegenerative Disease, Meeting Transcript; 2013 January 30. Available from: https://www.cms.gov/​Regulations-and-Guidance/​Guidance/​FACA/​downloads/​id66d.pdf (accessed on June 22, 2017). (CMS 2013, 79, 80, and 82)

    Back to Citation

    7.  The MCAC was the predecessor to the MEDCAC.

    Back to Citation

    8.  MEDCAC, Meeting: Positron Emission Tomography (FDG) for Alzheimer's Disease/Dementia (Diagnostic Imaging Panel), Meeting Transcript; 2002 January 10. https://www.cms.gov/​Regulations-and-Guidance/​Guidance/​FACA/​downloads/​id2a.pdf (accessed June 22, 2017).

    Back to Citation

    9.  Johnson et al., Appropriate use criteria for amyloid PET: A report of the Amyloid Imaging Task Force, the Society of Nuclear Medicine and Molecular Imaging, and the Alzheimer's Association, Alzheimer's and Dementia; 2013 January. http://www.alz.org/​research/​downloads/​appropriate_​use_​criteria_​for_​amyloid_​PET_​Alz_​and_​Dem_​January_​2013.pdf (accessed June 22, 2017).

    Back to Citation

    10.  MEDCAC, Meeting: Beta Amyloid Positron Emission Tomography (PET) in Dementia and Neurodegenerative Disease; 2013 January 30. https://www.cms.gov/​medicare-coverage-database/​details/​medcac-meeting-details.aspx?​MEDCACId=​66&​year=​2013&​bc=​AAAIAAAAAAAAAA%3d%3d&​ (accessed June 22, 2017).

    Back to Citation

    [FR Doc. 2018-07410 Filed 4-10-18; 8:45 am]