DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT
24 CFR Part 200
[Docket No. FR-4137-P-01]
RIN 2502-AG84
HUD Building Products Standards and Certification Program--Use of
Materials Bulletins
AGENCY: Office of the Assistant Secretary for Housing--Federal Housing
Commissioner, HUD.
ACTION: Proposed rule.
-----------------------------------------------------------------------
SUMMARY: This proposed rule would adopt a number of Use of Materials
Bulletins (UM) and references related to national voluntary consensus
standards in accordance with OMB Circular 119A. It also supplements the
HUD Building Product Standards and Certification Program by requiring
that additional information be included on the label, tag, or mark that
each manufacturer affixes to the certified product. The labeling of
these products is in the public interest because it will allow
consumers to readily identify those products that comply with existing
voluntary consensus standards. In addition, the adoption of a UM for a
product eliminates the need for manufacturers to seek HUD acceptance
through ``Materials Releases'' for individual products that meet the
standard of a UM. HUD accepts products that use on a generic basis for
use in houses covered under HUD mortgage insurance programs, thus
streamlining Departmental requirements. In addition, this proposed rule
specifies the frequency with which products should be tested in order
to be acceptable to HUD; and modifies section (d)(4)(ii) of 24 CFR
200.935 to allow the use of American Society for Quality Controls
(ASQC) standards 9000-94, 9001-94, 9002-94, 9003-94, & 9004-94 as
voluntary guidelines in any quality review.
DATES: Comment due date: July 18, 1997.
ADDRESSES: Interested persons are invited to submit comments regarding
this proposed rule to the Rules Docket Clerk, Office of the General
Counsel, Room 10276, Department of Housing & Urban Development, 451
Seventh Street, S.W., Washington, D.C. 20410-8000. Communication should
refer to the above docket number and title. A copy of each
communication submitted will be available for public inspection and
copying between 7:30 a.m. and 5:30 p.m. weekdays at the above address.
FAXED comments will not be accepted.
FOR FURTHER INFORMATION CONTACT: David R. Williamson, Director, Office
of Consumer and Regulatory Affairs, Department of Housing and Urban
Development, 451 Seventh Street S.W., Room 9156, Washington, D.C.
20410-8000; telephone: voice, (202) 708-6423; TTY, (202) 708-4594
(these are not toll free numbers.)
SUPPLEMENTARY INFORMATION: Pursuant to HUD's Building Product Standards
and Certification Programs, authorized by Section 521 of the National
Housing Act, 12 U.S.C. 1735e, the Department issues Use of Materials
Bulletins (UMs). The Use of Materials Bulletins are issued in the
public interest, to provide HUD standards that establish minimum
acceptable qualities for certain materials and products to be used in
properties subject to mortgages insured by the Department. In
accordance with 24 CFR 200.935, UMs are also used in third-party
labeling and certification programs to assure that building products
used in HUD programs meet the appropriate national voluntary standards.
The Department of Housing and Urban Development issues ``Materials
Releases'' to individual manufacturers for the specific acceptance of
new or innovative building products where there are no existing
standards. ``Use of Materials Bulletins'' are also issued by the
Department for the acceptance of new products on a generic or class
basis, thus making it unnecessary for individual manufacturers to
continue applying for approval of similar products, and making the
approval process overall much less cumbersome. This proposed rule
permits public comment prior to the issuance of a Use of Materials
Bulletin.
Materials Releases are periodically renewed or revised, for a fee,
by the Department. In cases where there are many manufacturers of
similar new products, or standards developed that cover these products,
the Department cancels the Materials Releases and refers to the new
standard and a certification program in a Use of Materials Bulletin.
With the promulgation of a Use of Materials Bulletin, individual
manufacturers no longer have to pay a fee to the Department for the
maintenance of their Materials Releases, and the Department no longer
has the administrative burden of renewing or revising the individual
Materials Releases. For these reasons, in the future, the Department
anticipates increasing its reliance on Use of Materials Bulletins to
accept new or innovative building products.
This proposed rule would promulgate or revise the following Use of
Materials Bulletins:
UM 73b Plastic Plumbing Fixtures at Sec. 200.937.
UM 44e Carpet at Sec. 200.942.
UM 38j Grademarking of Lumber at Sec. 200.943.
UM 40c Plywood at Sec. 200.944.
UM 72b Carpet Cushion at Sec. 200.948.
UM 105 Elastomeric Joint Sealants at Sec. 200.951.
UM 70b Particleboard Stair Treads at Sec. 200.952.
UM 110 Sprayed Polyurethane Foam Roof Insulation at Sec. 200.953.
UM 60a Construction Adhesives for Field Glued Wood Floor Systems at
Sec. 200.954.
UM 111 Fenestration Products (Windows and Doors) at Sec. 200.955.
Third-party certification programs for elastomeric joint sealants
and sprayed polyurethane foam for roof insulation have been informally
accepted by the Department, and by this rule are designated as new
Bulletins UM 105 and UM 110 under the procedures of 24 CFR 200.935.
In addition, paragraph (d)(4)(ii) of 24 CFR 200.935 is being
modified to allow the use of American Society for Quality Control
standards 9000-94, 9001-94, 9002-94, 9003-94, and 9004-94 as voluntary
guidelines in any quality review. These standards are identical to the
International Standards Organization standards. This change is
necessary because no criteria currently exist for a HUD determination
of an acceptable quality assurance program.
The Department has evaluated the updated technical standards
prepared by national standards organizations, and plans to adopt these
standards by incorporating them in the UM by reference. The UMs adopted
would also augment the labeling requirements of 24 CFR 200.935(d)(6).
In addition, the Department is also requesting comments on the
frequency of testing specified for each third party certification
program.
The reference in Sec. 900.929(b)(2) to the MPS compilation is
updated to cite the 1994 edition.
Copies of UMs are available for public inspection during regular
business hours in the Office of Consumer and Regulatory Affairs,
Department of Housing and Urban Development, Room 9156, 451 Seventh
Street S.W., Washington, DC., 20410-8000.
Findings and Certifications
Regulatory Planning and Review
This proposed rule has been reviewed in accordance with Executive
Order 12866, issued by the President on
[[Page 27487]]
September 30, 1993 (58 FR 51735, October 4, 1993). Any changes to the
proposed rule resulting from this review are available for public
inspection between 7:30 a.m. and 5:30 p.m. weekdays in the Office of
the Rules Docket Clerk.
Paperwork Reduction Act Statement
The proposed information collection requirements contained at
Secs. 900.937, 900.942, 900.943, 900.944, 900.948, 900.951, 900.952,
900.953, 900.954, and 900.955 of this rule have been submitted to the
Office of Management and Budget (OMB) for review, under section 3507(d)
of the Paperwork Reduction Act of 1995 (44 U.S.C. Chapter 35). An
agency may not conduct or sponsor, and a person is not required to
respond to, a collection of information unless the collection displays
a valid control number.
(a) Estimate of the total reporting and recordkeeping burden that
will result from the collection of information:
----------------------------------------------------------------------------------------------------------------
Est. avg. Est. annual
Reporting Burden Number of Freq. of response burden
respondents response time (hrs.) (hrs.)
----------------------------------------------------------------------------------------------------------------
20 20 1 400
---------------------------------------------------
Totaling Reporting Burden............................. ........... ........... ........... 400
----------------------------------------------------------------------------------------------------------------
(b) In accordance with 5 CFR 1320.8(d)(1), the Department is
soliciting comments from members of the public and affected agencies
concerning the proposed collection of information to:
(1) Evaluate whether the proposed collection of information is
necessary for the proper performance of the functions of the agency,
including whether the information will have practical utility;
(2) Evaluate the accuracy of the agency's estimate of the burden of
the proposed collection of information;
(3) Enhance the quality, utility, and clarity of the information to
be collected; and
(4) Minimize the burden of the collection of information on those
who are to respond; including through the use of appropriate automated
collection techniques or other forms of information technology, e.g.,
permitting electronic submission of responses.
Interested persons are invited to submit comments regarding the
information collection requirements in this proposal. Under the
provisions of 5 CFR part 1320, OMB is required to make a decision
concerning this collection of information between 30 and 60 days after
today's publication date. Therefore, a comment on the information
collection requirements is best assured of having its full effect if
OMB receives the comment within 30 days of today's publication. This
time frame does not affect the deadline for comments to the agency on
the proposed rule, however. Comments must refer to the proposal by name
and docket number (FR-4137) and must be sent to: Joseph F. Lackey, Jr.
HUD Desk Officer, Office of Management and Budget, New Executive Office
Building, Washington, DC 20503.
Unfunded Mandates Reform Act
Title II of the Unfunded Mandates Reform Act of 1995 establishes
requirements for Federal agencies to assess the effects of their
regulatory actions on State, local, and tribal governments and the
private sector. This proposed rule does not impose any Federal mandates
on any State, local or tribal governments or the private sector within
the meaning of the Unfunded Mandates Reform Act of 1995.
Environmental Impact
A Finding of No Significant Impact with respect to the environment
has been made in accordance with HUD regulations in 24 CFR Part 50,
which implement Section 102(2)(C) of the National Environmental Policy
Act of 1969, 42 U.S.C. 4332. The Finding of No Significant Impact is
available for public inspection and copying between 7:30 a.m. and 5:30
p.m. weekdays in the Office of the Rules Docket Clerk, Room 10276, 451
Seventh Street, SW, Washington, D.C. 20410.
Impact on Small Entities
The Secretary, in accordance with the Regulatory Flexibility Act (5
U.S.C. 605(b)) has reviewed and approved this proposed rule, and in so
doing certifies that this proposed rule will not have a significant
economic impact on a substantial number of small entities. These Use of
Materials Bulletins adopt standards that are nationally recognized
throughout the affected industry and will not create a burden on
manufacturers currently meeting the standards. The proposed rule will
have no adverse or disproportionate economic impact on small
businesses.
Federalism Impact
The General Counsel has determined, as the Designated Official for
HUD under section 6(a) of Executive Order 12612, Federalism, that this
proposed rule does not have federalism implications concerning the
division of local, State, and federal responsibilities. The rule only
proposes to adopt standards that are already nationally recognized
throughout the affected industry.
Executive Order 13045, Protection of Children from Environmental Health
Risks and Safety Risks
This proposed rule will not pose an environmental health risk or
safety risk on children.
List of Subjects in 24 CFR Part 200
Administrative practice and procedure, Claims, Equal employment
opportunity, Fair housing, Home improvement, Housing standards,
Incorporation by reference, Lead poisoning, Loan programs--housing and
community development, Minimum property standards, Mortgage insurance,
Organization and functions (Government agencies), Penalties, Reporting
and recordkeeping requirements, Social security, Unemployment
compensation, Wages.
Accordingly, 24 CFR part 200 is proposed to be amended as follows:
PART 200--INTRODUCTION
1. The authority citation for 24 CFR part 200 is revised to read as
follows:
Authority: Titles I and II of the National Housing Act (12
U.S.C. 1701 through 1715z-18); sec. 7(d), Department of Housing and
Urban Development Act (42 U.S.C. 3535 (d)).
2. In Sec. 200.929, paragraph (b)(2) is revised to read as follows:
Sec. 200.929 Description and identification of minimum property
standards.
* * * * *
(b) * * *
(2) MPS for Housing 4910.1, 1994 edition. This volume applies to
buildings and sites designed and used for normal multifamily occupancy,
[[Page 27488]]
including both unsubsidized and subsidized insured housing, and to
care-type housing insured under the National Housing Act. It also
includes, in Appendix K, a reprint of the MPS for One and Two Family
Dwellings identified in paragraph (b)(1) of this section.
3. Section 200.931 is revised to read as follows:
Sec. 200.931 Statement of availability.
Updated copies of the Minimum Property Standards and Use of
Materials Bulletins are available for public examination in the Office
of Consumer and Regulatory Affairs, Department of Housing and Urban
Development, room 9156, 451 Seventh St. S.W., Washington, D.C. 20410-
8000, and at the Office of the Federal Register, 800 North Capitol
Street, NW, Suite 700, Washington, D.C., 20408. In addition, copies of
volumes 1, 2, and 3 of the Minimum Property Standards may be purchased
from the U.S. Government Printing Office, Washington, D.C. 20402.
4. In Sec. 200.935, paragraph (d)(4)(ii) is revised to read as
follows:
Sec. 200.935 Administrator qualifications and procedures for HUD
building products certification programs.
* * * * *
(d) * * *
(4) * * *
(ii) Quality assurance system review. (A) Each administrator shall
examine a participating manufacturer's facilities and quality assurance
system procedures to determine that they are adequate to assure
continuing production of the product that complies with the applicable
standard. These quality assurance systems procedures shall be
documented in the administrator's and the manufacturer's files. If a
manufacturer's quality assurance system is not satisfactory to the
administrator, validation of the manufacturer's declaration of
certification shall be withheld. The following American Society for
Quality Control (ASQC) standards, which are incorporated by reference
and which are identical to the International Standards Organization
standards, may be used as guidelines in any quality assurance review:
(1) ASQC Q 9000-94 Quality Management and Quality Assurance
Standards Guidelines for Selection and Use;
(2) ASQC Q 9001-94 Quality Systems-Model for Quality Assurance in
Design, Development, Production, Installation, and Servicing;
(3) ASQC Q 9002-94 Quality Systems-Model for Quality in Production
and Installation;
(4) ASQC Q 9003-94 Quality Systems-Model for Quality Assurance in
Final Inspection and Test;
(5) ASQC Q 9004-94 Quality Management and Quality System Elements-
Guidelines.
(B) These standards have been approved by the Director of the
Federal Register for incorporation by reference in accordance with 5
U.S.C. 552(a) and 1 CFR part 51. They are available from the American
Society for Quality Control (ASQC), 310 West Wisconsin Avenue,
Milwaukee, WI 53208.
* * * * *
5. Section 200.937 is revised to read as follows:
Sec. 200.937 Supplementary specific requirements under the HUD
building product standards and certification program for plastic
plumbing fixtures.
(a) Applicable standards. (1) All plastic plumbing fixtures shall
be designed, manufactured, and tested in compliance with the following
American National Standards Institute (ANSI) standards, which are
incorporated by reference:
(i) ANSI Z 124.1-95 Plastic Bathtub Units;
(ii) ANSI Z 124.2-95 Plastic Shower Receptors;
(iii) ANSI Z 124.3-95 Plastic Lavatories;
(iv) ANSI Z 124.4-96 Plastic Water Closets, Bowls, & Tanks;
(v) ANSI Z 124.6-90 Plastic Sinks; and
(vi) ANSI Z 124.7-93 Plastic Spa Shells.
(2) These standards have been approved by the Director of the
Federal Register for incorporation by reference in accordance with 5
U.S.C. 552(a) and 1 CFR part 51. They are available from the American
National Standards Institute, Inc., 11 West 42nd Street, New York, New
York 10036.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6) concerning labeling of a product, the administrator's
validation mark and the manufacturer's certification of compliance with
the applicable standards are required to be on the certification label
issued by the administrator to the manufacturer. Each plastic plumbing
fixture shall be marked as conforming to UM 73b. The label shall be
located on each plastic plumbing fixture so that it is available for
inspection. The label shall include the manufacturer's name and plant
location.
(c) Periodic tests and quality assurance inspections. Under the
procedures concerning periodic tests and quality assurance inspections,
the frequency of testing for a product shall be described in the
specific building product certification program. In the case of plastic
plumbing fixtures, testing and inspection shall be conducted as
follows:
(1) At least every year, the administrator shall visit the
manufacturer's facility to select a sample of each certified plastic
plumbing fixture for testing in a laboratory accredited by the National
Voluntary Laboratory Accreditation Program (NVLAP) of the U.S.
Department of Commerce.
(2) The administrator shall also review the quality assurance
procedures once a year to assure that they are being followed by the
manufacturer.
Secs. 200.938, 200.939, and 200.941 [Removed]
6. Sections 200.938, 200.939, and 200.941 are removed.
7. Section 200.942 is revised to read as follows:
Sec. 200.942 Supplementary specific requirements under the HUD
building product standards and certification program for carpets and
carpets with attached cushions.
(a) Applicable standards. (1) All carpets and carpets with attached
cushions shall be designed, manufactured, and tested in compliance with
the following standards:
(i) ASTM D297-95 Standard Test Method for Rubber Products-Chemical
Analysis;
(ii) ASTM D5848-95 Standard Test Method for Mass per Unit Area of
Pile Floor Coverings;
(iii) ASTM D1335-72 Standard Test Method for Pile Floor Coverings;
(iv) ASTM D3936-90 Test Method for Delamination of Secondary
Backing of Pile Coverings;
(v) ASTM D2646-95 Test Method for Backing Fabrics;
(vi) AATCC 16E-93 Test Method for Colorfastness to Light-Xenon; and
(vii) AATCC 165-93 Test for Crocking.
(2) These standards have been approved by the Director of the
Federal Register for incorporation by reference in accordance with 5
U.S.C. 552(a) and 1 CFR part 51. They are available from the American
Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West
Conshohocken, Pennsylvania 19428; the American Association of Textile
Chemists and Colorists (AATCC), P.O. Box 12215, Research Triangle Park,
NC 27709; U.S. Department of Commerce, NIST, NVLAP, Gaithersburg, MD
20899.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6)
[[Page 27489]]
concerning labeling of a product, the administrator's validation mark
and the manufacturer's certification of compliance with the applicable
standards are required to be on the certification label issued by the
administrator to the manufacturer. Each carpet shall be marked at
intervals of at least 6 feet and no less than 1 foot from the edge, in
compliance with UM 44e. The label shall include the manufacturer's
name, plant location, and statement of compliance with UM 44e.
(c) Periodic tests and quality assurance inspections.
Under the procedures set forth in 24 CFR 200.935(d)(8) concerning
periodic tests and quality assurance inspections, the frequency of
testing for a product shall be described in the specific building
product certification program. In the case of carpet and carpet with
attached cushion, testing and inspection shall be conducted as follows:
(1) Two samples of each certified quality shall be taken every six
months from the manufacturer and one sample annually from the public
marketplace for testing in a laboratory accredited by the National
Voluntary Laboratory Accreditation Program (NVLAP) of the U.S.
Department of Commerce.
(2) The administrator shall also review the quality procedures
twice a year to assure that they are being followed by the
manufacturer.
(d) Cut pile polypropylene carpet. Provisions for cut pile
polypropylene are included under UM 44e.
8. Section 200.943 is revised to read as follows:
Sec. 200.943 Supplementary specific requirements under the HUD
building product standards and certification program for the
grademarking of lumber.
(a) Applicable Standard. (1) In accordance with UM 38j, lumber
shall be grademarked in compliance with the U.S. Department of Commerce
Voluntary Product Standard PS-20-94 American Softwood Lumber Standard.
(2) This standard has been approved by the Director of the Federal
Register for incorporation by reference in accordance with 5 U.S.C.
552(a) and 1 CFR part 51. It is available from U.S. Department of
Commerce, American Lumber Standard Committee (ALSC), P.O. Box 210,
Germantown, Maryland 20875-0210.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6) concerning labeling of a product, the administrator's
validation mark and the manufacturer's certification of compliance with
the applicable standard are required on the certification label issued
by the administrator to the manufacturer. The certification mark shall
be affixed to each piece of lumber. In the case of grademarking of
lumber, the following information shall be included on the
certification label or mark:
(1) The registered symbol which identifies the grading agency;
(2) Species or species combination;
(3) Grade;
(4) Identification of the applicable grading rules when not
indicated by the species identification or agency symbol;
(5) Mill or grader;
(6) For members which are less than 5 inches in nominal thickness,
indication that the lumber was green or dry at the time of dressing;
and
(7) Indication that the lumber was finger jointed.
(c) Periodic tests and quality assurance. Periodic tests and
quality assurance inspections shall be carried out by the American
Lumber Standard Committee as defined in PS 20-94.
9. Section 200.944 is revised to read as follows:
Sec. 200.944 Supplementary specific requirements under the HUD
building product standards and certification program for plywood and
other wood-based structural-use panels.
(a) Applicable standards. (1) All plywood prescriptively designed,
manufactured, and tested shall be in compliance with the U.S.
Department of Commerce Voluntary Product Standard PS 1-95. Plywood
panels not meeting the grade requirements of PS 1-95 and all composite
and non-veneer structural-use panels shall comply with the
``Performance Standards and Policies for Structural-Use Panels-94''
(APA Standard PRP 108-94 or TECO Standard PRP 133-94) except that the
American Society for Testing and Materials (ASTM) Standard ASTM D 3043-
87 Method B may be used.
(2) These standards have been approved by the Director of the
Federal Register for incorporation by reference in accordance with 5
U.S.C. 552(a) and 1 CFR part 51. They are available from the U.S.
Department of Commerce, NIST, Gaithersburg, MD 20899; APA-The
Engineered Wood Association, 7011 South 19th St., Tacoma, WA 98411;
TECO/PFS Inc., 2402 Daniels Street, Madison, WI 53704; American Society
for Testing and Materials (ASTM), 100 Barr Harbor Drive, West
Conshohocken, Pennsylvania 19428.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6) concerning labeling of a product, the administrator's
validation mark and the manufacturer's certification of compliance with
the applicable standards are required to be on the certification label
issued by the administrator to the manufacturer. All plywood panels
made to PS 1-95 prescriptive or performance standards shall be marked
as complying to PS 1-95. All plywood products not meeting the
requirements of PS 1-95 and all composite and non-veneer structural-use
panels that do not comply with APA PRP 108-94 or TECO PRP 133-94 shall
be marked as complying with UM 40c. The label shall be located on each
panel so that it is available for inspection. The label shall include
the manufacturer's name and mill number.
(c) Periodic tests and quality assurance. Under the procedures
concerning periodic tests and quality assurance inspections, the
frequency of testing for a product shall be described in the specific
building product certification program. In the case of plywood and
other wood-based structural-use panels, testing and inspection shall be
conducted as follows:
(1) At least three times a year, the administrator shall visit the
manufacturer's facility to select 10 panels of each certified product
for testing in a laboratory accredited by the National Voluntary
Laboratory Accreditation Program (NVLAP) of the U.S. Department of
Commerce.
(2) The administrator shall also review the quality assurance
procedures three times a year to assure that they are being followed by
the manufacturer.
10. Section 200.948 is revised to read as follows:
Sec. 200.948 Supplementary specific requirements under the HUD
building product standards and certification program for carpet
cushion.
(a) Applicable standards. (1) All carpet cushion shall be designed,
manufactured, and tested in compliance with the following standards:
(i) ASTM D3574-95 Test Method for Flexible Cellular Materials;
(ii) ASTM D297-95 Standard Test Method for Rubber Products Chemical
Analysis;
(iii) ASTM D629-95 Test Methods for Quantitative Analysis of
Textiles;
(iv) ASTM D1667-90 Specification for Flexible Cellular Materials;
(v) ASTM D2646-95 Test Method for Backing Fabrics;
(vi) ASTM D3696-90 Test Method for Delamination of Secondary
Backing of Pile Coverings.
(2) These standards have been approved by the Director of the
Federal Register for incorporation by reference in accordance with 5
U.S.C. 552(a) and
[[Page 27490]]
1 CFR part 51. They are available from the American Society for Testing
and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken,
Pennsylvania 19428.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6) concerning labeling of a product, the administrator's
validation mark and the manufacturer's certification of compliance with
the applicable standards are required to be on the certification label
issued by the administrator to the manufacturer. Each carpet cushion
shall be marked as to type and class, and as conforming to UM 72b.
(c) Periodic tests and quality assurance. Under the procedures set
forth in 200.935(d)(8), testing and inspection shall be conducted as
follows:
(1) At least twice a year, the administrator shall visit the
manufacturer's facility to select a sample of each certified carpet
cushion for testing by a laboratory approved by the administrator.
(2) The administrator shall review the quality assurance procedures
every six months to assure that they are being followed by the
manufacturer.
11. A new Sec. 200.951 is added to read as follows:
Sec. 200.951 Supplementary specific requirements under the HUD
building product standard and certification program for elastomeric
joint sealants.
(a) Applicable standards. (1) All elastomeric joint sealants shall
be designed, manufactured, and tested in compliance with the following
American Society for Testing and Materials standards:
(i) ASTM C920-94 Standard Specification for Elastomeric Joint
Sealants, except that there be a maximum of 25% loss of elongation when
determined after curing and 2500 hours of ultra-violet light in a xenon
arc accelerated weathering test for Class 25 materials compared to a
cured non-exposed sample;
(ii) ASTM C1193-91 Standard Guide for the Use of Elastomeric
Sealants.
(2) These standards have been approved by the Director of the
Federal Register for incorporation by reference in accordance with 5
U.S.C. 552(a) and 1 CFR part 51. They are available from the American
Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West
Conshohocken, Pennsylvania 19428.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6) concerning labeling of a product, the administrator's
validation mark and the manufacturer's certification of compliance with
the applicable standards are required to be on the certification label
issued by the administrator to the manufacturer. Each container of
elastomeric joint sealant shall include the sealant's type, grade,
class, and use, and the manufacturer's name, plant location and
statement of compliance with UM 105.
(c) Periodic tests and quality assurance inspections. Under the
procedures set forth in 24 CFR 200.935(d)(8) concerning periodic tests
and quality assurance inspections, the frequency of testing for a
product shall be described in the specific building product
certification program. In the case of elastomeric joint sealants,
testing and inspection shall be conducted as follows:
(1) At least once every year, the administrator shall visit the
manufacturer's facility to select a sample for testing in a laboratory
accredited by the National Voluntary Laboratory Accreditation Program
(NVLAP) of the U.S. Department of Commerce.
(2) The administrator shall also review the quality assurance
procedures once a year to assure that they are being followed by the
manufacturer.
12. A new Sec. 200.952 is added to read as follows:
Sec. 200.952 Supplementary specific requirements under the HUD
building product standards and certification program for interior
particleboard stair treads.
(a) Applicable standards. (1) All interior particleboard stair
treads shall be designed, manufactured, and tested in compliance with
ANSI A208.1 Mat-Formed Wood Particleboard, Grade M-3.
(2) This standard has been approved by the Director of the Federal
Register for incorporation by reference in accordance with 5 U.S.C.
552(a) and 1 CFR part 51, and is available from the American National
Standards Institute, Inc., 11 West 42nd Street, New York, New York
10036.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6) concerning labeling of a product, the administrator's
validation mark and the manufacturer's certification of compliance with
the applicable standard are required to be on the certification label
issued by the administrator to the manufacturer. Each interior
particleboard stair tread shall include the manufacturer's statement of
conformance to UM 70b, a statement that this product is for interior
use only, and the manufacturer's name and plant location.
(c) Periodic tests and quality assurance. Under the procedures set
forth in 24 CFR 200.935(d)(8) concerning periodic tests and quality
assurance inspections, the frequency of testing for a product shall be
described in the specific building product certification program. In
the case of interior particleboard stair treads, testing and inspection
shall be conducted as follows:
(1) At least once every three months, the administrator shall visit
the manufacturer's facility to select a sample for testing in a
laboratory approved by the administrator.
(2) The administrator shall also review the quality assurance
procedures twice a year to assure that they are being followed by the
manufacturer.
13. A new Sec. 200.953 is added to read as follows:
Sec. 200.953 Supplementary specific requirements under the HUD
building product standards and certification program for sprayed
polyurethane foam for roof insulation.
(a) Applicable standards. (1) All sprayed polyurethane foam for
roof insulation shall be designed, manufactured, and tested in
compliance with ASTM C1029-93 Standard Specification for Spray Applied
Rigid Cellular Polyurethane Thermal Insulation. The foam shall be
installed in accordance with ASTM D5469-93 Standard Guide for
Application of New Spray Applied Polyurethane Foam and Coated Roofing
Systems, and designed in accordance with the Society of the Plastics
Industry (SPI) standard PFCD AY 104-90 Recommended Design
Considerations and Guide Specifications.
(2) These standards have been approved by the Director of the
Federal Register for incorporation by reference in accordance with 5
U.S.C. 552(a) and 1 CFR part 51. They are available from the American
National Standards Institute, Inc., 11 West 42nd Street, New York, New
York 10036, or the Society of the Plastics Industry (SPI), 1275 K
Street, NW, Suite 400, Washington, D.C., 20005.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6) concerning labeling of a product, the administrator's
validation mark and the manufacturer's certification of compliance with
the applicable standard are required to be on the certification label
issued by the administrator to the manufacturer. Each container or
package of sprayed polyurethane foam roof insulation
[[Page 27491]]
material shall be marked as conforming to UM 110. The label shall
include the manufacturer's name and plant location.
(c) Periodic tests and quality assurance inspections. Under the
procedures set forth in 24 CFR 200.935(d)(8) concerning periodic tests
and quality assurance inspections, the frequency of testing for a
product shall be described in the specific building product
certification program. In the case of sprayed polyurethane foam for
room insulation, testing and inspection shall be conducted as follows:
(1) At least twice a year, the administrator shall visit the
manufacturer's facility to select a sample for testing in an approved
laboratory with the applicable standard.
(2) The administrator shall also review the quality assurance
procedures twice a year to assure that they are being followed by the
manufacturer.
14. A new Sec. 200.954 is added to read as follows:
Sec. 200.954 Supplementary specific requirements under the HUD
building product standard and certification program for flooring
adhesives.
(a) Applicable Standards. (1) All construction adhesives for field
glued wood floor systems shall be designed, manufactured, and tested in
compliance with the following American Society for Testing and
Materials (ASTM) standard D3498-93 Specifications for Adhesive for
Field-Gluing Plywood to Lumber Framing for Floor Systems except that
the mold and bacteria resistance tests shall not be included.
(2) This standard has been approved by the Director of the Federal
Register for incorporation by reference in accordance with 5 U.S.C.
552(a) and 1 CFR part 51, and is available from the American Society
for Testing & Materials Inc., 100 Barr Harbor Drive, West Conshohocken,
PA. 19428.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6) concerning labeling of a product, the Administrator's
validation mark and the manufacturer's certification of compliance with
the applicable standard are required to be on the certification label
issued by the Administrator to the manufacturer. Each container shall
be marked as being in compliance with UM 60a. The label shall also
include the manufacturer's name, plant location, and shelf life.
(c) Periodic Tests and Quality Assurance. Under the procedures set
forth in 24 CFR 200.935(d)(8) concerning periodic tests and quality
assurance inspections, the frequency of testing for a product shall be
described in the specific building product certification program. In
the case of construction adhesives for field glued wood floor systems,
testing and inspection shall be conducted as follows:
(1) At least every six months, the administrator shall visit the
manufacturer's facility to select a sample for testing in a laboratory
approved by the administrator.
(2) The administrator shall also review the quality assurance
procedures twice a year to assure that they are being followed by the
manufacturer.
15. A new Sec. 200.955 is added to read as follows:
Sec. 200.955 Supplementary specific requirements under the HUD
building product standard and certification program for fenestration
products (windows and doors).
(a) Applicable Standards. (1) All windows and doors shall be
designed, manufactured, and tested in compliance with American
Architectural Manufacturers Association (AAMA) standard, AAMA 101/
I.S.2-97, Voluntary Specifications for Aluminum, Vinyl (PVC), and Wood
Windows and Glass Doors.
(2) This standard has been approved by the Director of the Federal
Register for incorporation by reference in accordance with 5 U.S.C.
552(a) and 1 CFR part 51, and is available from the American
Architectural Manufacturers Association, 1540 East Dundee Road,
Paletine, IL 60067.
(b) Labeling. Under the procedures set forth in 24 CFR
200.935(d)(6) concerning labeling of a product, the administrator's
validation mark and the manufacturer's certification of compliance with
the applicable standards are required to be on the certification label
issued by the administrator to the manufacturer. Each window or glass
door shall include the manufacturer's name, plant location, and
statement of compliance with UM 111.
(c) Periodic Tests and Quality Assurance Inspections. Under the
procedures set forth in 24 CFR 200.935(d)(8) concerning periodic tests
and quality assurance inspections, the frequency of testing for a
product shall be described in the specific building product
certification program. In the case of windows and glass doors, testing
and inspection shall be conducted as follows:
(1) At least once every four years, the administrator shall visit
the manufacturer's facility to select a commercial sample for testing
in a laboratory approved by the administrator.
(2) The administrator shall also review the quality assurance