97-13048. HUD Building Products Standards and Certification ProgramUse of Materials Bulletins  

  • [Federal Register Volume 62, Number 96 (Monday, May 19, 1997)]
    [Proposed Rules]
    [Pages 27486-27491]
    From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
    [FR Doc No: 97-13048]
    
    
    
    [[Page 27485]]
    
    _______________________________________________________________________
    
    Part VIII
    
    
    
    
    
    Department of Housing and Urban Development
    
    
    
    
    
    _______________________________________________________________________
    
    
    
    24 CFR Part 200
    
    
    
    HUD Building Products Standards and Certification Program--Use of 
    Materials Bulletins; Proposed Rule
    
    Federal Register / Vol. 62, No. 96 / Monday, May 19, 1997 / Proposed 
    Rules
    
    [[Page 27486]]
    
    
    =======================================================================
    -----------------------------------------------------------------------
    
    
    DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT
    
    24 CFR Part 200
    
    [Docket No. FR-4137-P-01]
    RIN 2502-AG84
    
    
    HUD Building Products Standards and Certification Program--Use of 
    Materials Bulletins
    
    AGENCY: Office of the Assistant Secretary for Housing--Federal Housing 
    Commissioner, HUD.
    
    ACTION: Proposed rule.
    
    -----------------------------------------------------------------------
    
    SUMMARY: This proposed rule would adopt a number of Use of Materials 
    Bulletins (UM) and references related to national voluntary consensus 
    standards in accordance with OMB Circular 119A. It also supplements the 
    HUD Building Product Standards and Certification Program by requiring 
    that additional information be included on the label, tag, or mark that 
    each manufacturer affixes to the certified product. The labeling of 
    these products is in the public interest because it will allow 
    consumers to readily identify those products that comply with existing 
    voluntary consensus standards. In addition, the adoption of a UM for a 
    product eliminates the need for manufacturers to seek HUD acceptance 
    through ``Materials Releases'' for individual products that meet the 
    standard of a UM. HUD accepts products that use on a generic basis for 
    use in houses covered under HUD mortgage insurance programs, thus 
    streamlining Departmental requirements. In addition, this proposed rule 
    specifies the frequency with which products should be tested in order 
    to be acceptable to HUD; and modifies section (d)(4)(ii) of 24 CFR 
    200.935 to allow the use of American Society for Quality Controls 
    (ASQC) standards 9000-94, 9001-94, 9002-94, 9003-94, & 9004-94 as 
    voluntary guidelines in any quality review.
    
    DATES: Comment due date: July 18, 1997.
    
    ADDRESSES: Interested persons are invited to submit comments regarding 
    this proposed rule to the Rules Docket Clerk, Office of the General 
    Counsel, Room 10276, Department of Housing & Urban Development, 451 
    Seventh Street, S.W., Washington, D.C. 20410-8000. Communication should 
    refer to the above docket number and title. A copy of each 
    communication submitted will be available for public inspection and 
    copying between 7:30 a.m. and 5:30 p.m. weekdays at the above address. 
    FAXED comments will not be accepted.
    
    FOR FURTHER INFORMATION CONTACT: David R. Williamson, Director, Office 
    of Consumer and Regulatory Affairs, Department of Housing and Urban 
    Development, 451 Seventh Street S.W., Room 9156, Washington, D.C. 
    20410-8000; telephone: voice, (202) 708-6423; TTY, (202) 708-4594 
    (these are not toll free numbers.)
    
    SUPPLEMENTARY INFORMATION: Pursuant to HUD's Building Product Standards 
    and Certification Programs, authorized by Section 521 of the National 
    Housing Act, 12 U.S.C. 1735e, the Department issues Use of Materials 
    Bulletins (UMs). The Use of Materials Bulletins are issued in the 
    public interest, to provide HUD standards that establish minimum 
    acceptable qualities for certain materials and products to be used in 
    properties subject to mortgages insured by the Department. In 
    accordance with 24 CFR 200.935, UMs are also used in third-party 
    labeling and certification programs to assure that building products 
    used in HUD programs meet the appropriate national voluntary standards.
        The Department of Housing and Urban Development issues ``Materials 
    Releases'' to individual manufacturers for the specific acceptance of 
    new or innovative building products where there are no existing 
    standards. ``Use of Materials Bulletins'' are also issued by the 
    Department for the acceptance of new products on a generic or class 
    basis, thus making it unnecessary for individual manufacturers to 
    continue applying for approval of similar products, and making the 
    approval process overall much less cumbersome. This proposed rule 
    permits public comment prior to the issuance of a Use of Materials 
    Bulletin.
        Materials Releases are periodically renewed or revised, for a fee, 
    by the Department. In cases where there are many manufacturers of 
    similar new products, or standards developed that cover these products, 
    the Department cancels the Materials Releases and refers to the new 
    standard and a certification program in a Use of Materials Bulletin.
        With the promulgation of a Use of Materials Bulletin, individual 
    manufacturers no longer have to pay a fee to the Department for the 
    maintenance of their Materials Releases, and the Department no longer 
    has the administrative burden of renewing or revising the individual 
    Materials Releases. For these reasons, in the future, the Department 
    anticipates increasing its reliance on Use of Materials Bulletins to 
    accept new or innovative building products.
        This proposed rule would promulgate or revise the following Use of 
    Materials Bulletins:
    
    UM 73b  Plastic Plumbing Fixtures at Sec. 200.937.
    UM 44e  Carpet at Sec. 200.942.
    UM 38j  Grademarking of Lumber at Sec. 200.943.
    UM 40c  Plywood at Sec. 200.944.
    UM 72b  Carpet Cushion at Sec. 200.948.
    UM 105  Elastomeric Joint Sealants at Sec. 200.951.
    UM 70b  Particleboard Stair Treads at Sec. 200.952.
    UM 110  Sprayed Polyurethane Foam Roof Insulation at Sec. 200.953.
    UM 60a  Construction Adhesives for Field Glued Wood Floor Systems at 
    Sec. 200.954.
    UM 111  Fenestration Products (Windows and Doors) at Sec. 200.955.
    
        Third-party certification programs for elastomeric joint sealants 
    and sprayed polyurethane foam for roof insulation have been informally 
    accepted by the Department, and by this rule are designated as new 
    Bulletins UM 105 and UM 110 under the procedures of 24 CFR 200.935.
        In addition, paragraph (d)(4)(ii) of 24 CFR 200.935 is being 
    modified to allow the use of American Society for Quality Control 
    standards 9000-94, 9001-94, 9002-94, 9003-94, and 9004-94 as voluntary 
    guidelines in any quality review. These standards are identical to the 
    International Standards Organization standards. This change is 
    necessary because no criteria currently exist for a HUD determination 
    of an acceptable quality assurance program.
        The Department has evaluated the updated technical standards 
    prepared by national standards organizations, and plans to adopt these 
    standards by incorporating them in the UM by reference. The UMs adopted 
    would also augment the labeling requirements of 24 CFR 200.935(d)(6). 
    In addition, the Department is also requesting comments on the 
    frequency of testing specified for each third party certification 
    program.
        The reference in Sec. 900.929(b)(2) to the MPS compilation is 
    updated to cite the 1994 edition.
        Copies of UMs are available for public inspection during regular 
    business hours in the Office of Consumer and Regulatory Affairs, 
    Department of Housing and Urban Development, Room 9156, 451 Seventh 
    Street S.W., Washington, DC., 20410-8000.
    
    Findings and Certifications
    
    Regulatory Planning and Review
    
        This proposed rule has been reviewed in accordance with Executive 
    Order 12866, issued by the President on
    
    [[Page 27487]]
    
    September 30, 1993 (58 FR 51735, October 4, 1993). Any changes to the 
    proposed rule resulting from this review are available for public 
    inspection between 7:30 a.m. and 5:30 p.m. weekdays in the Office of 
    the Rules Docket Clerk.
    
    Paperwork Reduction Act Statement
    
        The proposed information collection requirements contained at 
    Secs. 900.937, 900.942, 900.943, 900.944, 900.948, 900.951, 900.952, 
    900.953, 900.954, and 900.955 of this rule have been submitted to the 
    Office of Management and Budget (OMB) for review, under section 3507(d) 
    of the Paperwork Reduction Act of 1995 (44 U.S.C. Chapter 35). An 
    agency may not conduct or sponsor, and a person is not required to 
    respond to, a collection of information unless the collection displays 
    a valid control number.
        (a) Estimate of the total reporting and recordkeeping burden that 
    will result from the collection of information:
    
    ----------------------------------------------------------------------------------------------------------------
                                                                                             Est. avg.   Est. annual
                          Reporting Burden                         Number of     Freq. of     response      burden  
                                                                  respondents    response   time (hrs.)     (hrs.)  
    ----------------------------------------------------------------------------------------------------------------
                                                                           20           20            1          400
                                                                 ---------------------------------------------------
          Totaling Reporting Burden.............................  ...........  ...........  ...........          400
    ----------------------------------------------------------------------------------------------------------------
    
        (b) In accordance with 5 CFR 1320.8(d)(1), the Department is 
    soliciting comments from members of the public and affected agencies 
    concerning the proposed collection of information to:
        (1) Evaluate whether the proposed collection of information is 
    necessary for the proper performance of the functions of the agency, 
    including whether the information will have practical utility;
        (2) Evaluate the accuracy of the agency's estimate of the burden of 
    the proposed collection of information;
        (3) Enhance the quality, utility, and clarity of the information to 
    be collected; and
        (4) Minimize the burden of the collection of information on those 
    who are to respond; including through the use of appropriate automated 
    collection techniques or other forms of information technology, e.g., 
    permitting electronic submission of responses.
        Interested persons are invited to submit comments regarding the 
    information collection requirements in this proposal. Under the 
    provisions of 5 CFR part 1320, OMB is required to make a decision 
    concerning this collection of information between 30 and 60 days after 
    today's publication date. Therefore, a comment on the information 
    collection requirements is best assured of having its full effect if 
    OMB receives the comment within 30 days of today's publication. This 
    time frame does not affect the deadline for comments to the agency on 
    the proposed rule, however. Comments must refer to the proposal by name 
    and docket number (FR-4137) and must be sent to: Joseph F. Lackey, Jr. 
    HUD Desk Officer, Office of Management and Budget, New Executive Office 
    Building, Washington, DC 20503.
    
    Unfunded Mandates Reform Act
    
        Title II of the Unfunded Mandates Reform Act of 1995 establishes 
    requirements for Federal agencies to assess the effects of their 
    regulatory actions on State, local, and tribal governments and the 
    private sector. This proposed rule does not impose any Federal mandates 
    on any State, local or tribal governments or the private sector within 
    the meaning of the Unfunded Mandates Reform Act of 1995.
    
    Environmental Impact
    
        A Finding of No Significant Impact with respect to the environment 
    has been made in accordance with HUD regulations in 24 CFR Part 50, 
    which implement Section 102(2)(C) of the National Environmental Policy 
    Act of 1969, 42 U.S.C. 4332. The Finding of No Significant Impact is 
    available for public inspection and copying between 7:30 a.m. and 5:30 
    p.m. weekdays in the Office of the Rules Docket Clerk, Room 10276, 451 
    Seventh Street, SW, Washington, D.C. 20410.
    
    Impact on Small Entities
    
        The Secretary, in accordance with the Regulatory Flexibility Act (5 
    U.S.C. 605(b)) has reviewed and approved this proposed rule, and in so 
    doing certifies that this proposed rule will not have a significant 
    economic impact on a substantial number of small entities. These Use of 
    Materials Bulletins adopt standards that are nationally recognized 
    throughout the affected industry and will not create a burden on 
    manufacturers currently meeting the standards. The proposed rule will 
    have no adverse or disproportionate economic impact on small 
    businesses.
    
    Federalism Impact
    
        The General Counsel has determined, as the Designated Official for 
    HUD under section 6(a) of Executive Order 12612, Federalism, that this 
    proposed rule does not have federalism implications concerning the 
    division of local, State, and federal responsibilities. The rule only 
    proposes to adopt standards that are already nationally recognized 
    throughout the affected industry.
    
    Executive Order 13045, Protection of Children from Environmental Health 
    Risks and Safety Risks
    
        This proposed rule will not pose an environmental health risk or 
    safety risk on children.
    
    List of Subjects in 24 CFR Part 200
    
        Administrative practice and procedure, Claims, Equal employment 
    opportunity, Fair housing, Home improvement, Housing standards, 
    Incorporation by reference, Lead poisoning, Loan programs--housing and 
    community development, Minimum property standards, Mortgage insurance, 
    Organization and functions (Government agencies), Penalties, Reporting 
    and recordkeeping requirements, Social security, Unemployment 
    compensation, Wages.
    
        Accordingly, 24 CFR part 200 is proposed to be amended as follows:
    
    PART 200--INTRODUCTION
    
        1. The authority citation for 24 CFR part 200 is revised to read as 
    follows:
    
        Authority: Titles I and II of the National Housing Act (12 
    U.S.C. 1701 through 1715z-18); sec. 7(d), Department of Housing and 
    Urban Development Act (42 U.S.C. 3535 (d)).
    
        2. In Sec. 200.929, paragraph (b)(2) is revised to read as follows:
    
    
    Sec. 200.929  Description and identification of minimum property 
    standards.
    
    * * * * *
        (b) * * *
        (2) MPS for Housing 4910.1, 1994 edition. This volume applies to 
    buildings and sites designed and used for normal multifamily occupancy,
    
    [[Page 27488]]
    
    including both unsubsidized and subsidized insured housing, and to 
    care-type housing insured under the National Housing Act. It also 
    includes, in Appendix K, a reprint of the MPS for One and Two Family 
    Dwellings identified in paragraph (b)(1) of this section.
        3. Section 200.931 is revised to read as follows:
    
    
    Sec. 200.931  Statement of availability.
    
        Updated copies of the Minimum Property Standards and Use of 
    Materials Bulletins are available for public examination in the Office 
    of Consumer and Regulatory Affairs, Department of Housing and Urban 
    Development, room 9156, 451 Seventh St. S.W., Washington, D.C. 20410-
    8000, and at the Office of the Federal Register, 800 North Capitol 
    Street, NW, Suite 700, Washington, D.C., 20408. In addition, copies of 
    volumes 1, 2, and 3 of the Minimum Property Standards may be purchased 
    from the U.S. Government Printing Office, Washington, D.C. 20402.
        4. In Sec. 200.935, paragraph (d)(4)(ii) is revised to read as 
    follows:
    
    
    Sec. 200.935  Administrator qualifications and procedures for HUD 
    building products certification programs.
    
    * * * * *
        (d) * * *
        (4) * * *
        (ii) Quality assurance system review. (A) Each administrator shall 
    examine a participating manufacturer's facilities and quality assurance 
    system procedures to determine that they are adequate to assure 
    continuing production of the product that complies with the applicable 
    standard. These quality assurance systems procedures shall be 
    documented in the administrator's and the manufacturer's files. If a 
    manufacturer's quality assurance system is not satisfactory to the 
    administrator, validation of the manufacturer's declaration of 
    certification shall be withheld. The following American Society for 
    Quality Control (ASQC) standards, which are incorporated by reference 
    and which are identical to the International Standards Organization 
    standards, may be used as guidelines in any quality assurance review:
        (1) ASQC Q 9000-94 Quality Management and Quality Assurance 
    Standards Guidelines for Selection and Use;
        (2) ASQC Q 9001-94 Quality Systems-Model for Quality Assurance in 
    Design, Development, Production, Installation, and Servicing;
        (3) ASQC Q 9002-94 Quality Systems-Model for Quality in Production 
    and Installation;
        (4) ASQC Q 9003-94 Quality Systems-Model for Quality Assurance in 
    Final Inspection and Test;
        (5) ASQC Q 9004-94 Quality Management and Quality System Elements-
    Guidelines.
        (B) These standards have been approved by the Director of the 
    Federal Register for incorporation by reference in accordance with 5 
    U.S.C. 552(a) and 1 CFR part 51. They are available from the American 
    Society for Quality Control (ASQC), 310 West Wisconsin Avenue, 
    Milwaukee, WI 53208.
    * * * * *
        5. Section 200.937 is revised to read as follows:
    
    
    Sec. 200.937  Supplementary specific requirements under the HUD 
    building product standards and certification program for plastic 
    plumbing fixtures.
    
        (a) Applicable standards. (1) All plastic plumbing fixtures shall 
    be designed, manufactured, and tested in compliance with the following 
    American National Standards Institute (ANSI) standards, which are 
    incorporated by reference:
        (i) ANSI Z 124.1-95 Plastic Bathtub Units;
        (ii) ANSI Z 124.2-95 Plastic Shower Receptors;
        (iii) ANSI Z 124.3-95 Plastic Lavatories;
        (iv) ANSI Z 124.4-96 Plastic Water Closets, Bowls, & Tanks;
        (v) ANSI Z 124.6-90 Plastic Sinks; and
        (vi) ANSI Z 124.7-93 Plastic Spa Shells.
        (2) These standards have been approved by the Director of the 
    Federal Register for incorporation by reference in accordance with 5 
    U.S.C. 552(a) and 1 CFR part 51. They are available from the American 
    National Standards Institute, Inc., 11 West 42nd Street, New York, New 
    York 10036.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6) concerning labeling of a product, the administrator's 
    validation mark and the manufacturer's certification of compliance with 
    the applicable standards are required to be on the certification label 
    issued by the administrator to the manufacturer. Each plastic plumbing 
    fixture shall be marked as conforming to UM 73b. The label shall be 
    located on each plastic plumbing fixture so that it is available for 
    inspection. The label shall include the manufacturer's name and plant 
    location.
        (c) Periodic tests and quality assurance inspections. Under the 
    procedures concerning periodic tests and quality assurance inspections, 
    the frequency of testing for a product shall be described in the 
    specific building product certification program. In the case of plastic 
    plumbing fixtures, testing and inspection shall be conducted as 
    follows:
        (1) At least every year, the administrator shall visit the 
    manufacturer's facility to select a sample of each certified plastic 
    plumbing fixture for testing in a laboratory accredited by the National 
    Voluntary Laboratory Accreditation Program (NVLAP) of the U.S. 
    Department of Commerce.
        (2) The administrator shall also review the quality assurance 
    procedures once a year to assure that they are being followed by the 
    manufacturer.
    
    
    Secs. 200.938, 200.939, and 200.941  [Removed]
    
        6. Sections 200.938, 200.939, and 200.941 are removed.
        7. Section 200.942 is revised to read as follows:
    
    
    Sec. 200.942  Supplementary specific requirements under the HUD 
    building product standards and certification program for carpets and 
    carpets with attached cushions.
    
        (a) Applicable standards. (1) All carpets and carpets with attached 
    cushions shall be designed, manufactured, and tested in compliance with 
    the following standards:
        (i) ASTM D297-95 Standard Test Method for Rubber Products-Chemical 
    Analysis;
        (ii) ASTM D5848-95 Standard Test Method for Mass per Unit Area of 
    Pile Floor Coverings;
        (iii) ASTM D1335-72 Standard Test Method for Pile Floor Coverings;
        (iv) ASTM D3936-90 Test Method for Delamination of Secondary 
    Backing of Pile Coverings;
        (v) ASTM D2646-95 Test Method for Backing Fabrics;
        (vi) AATCC 16E-93 Test Method for Colorfastness to Light-Xenon; and
        (vii) AATCC 165-93 Test for Crocking.
        (2) These standards have been approved by the Director of the 
    Federal Register for incorporation by reference in accordance with 5 
    U.S.C. 552(a) and 1 CFR part 51. They are available from the American 
    Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West 
    Conshohocken, Pennsylvania 19428; the American Association of Textile 
    Chemists and Colorists (AATCC), P.O. Box 12215, Research Triangle Park, 
    NC 27709; U.S. Department of Commerce, NIST, NVLAP, Gaithersburg, MD 
    20899.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6)
    
    [[Page 27489]]
    
    concerning labeling of a product, the administrator's validation mark 
    and the manufacturer's certification of compliance with the applicable 
    standards are required to be on the certification label issued by the 
    administrator to the manufacturer. Each carpet shall be marked at 
    intervals of at least 6 feet and no less than 1 foot from the edge, in 
    compliance with UM 44e. The label shall include the manufacturer's 
    name, plant location, and statement of compliance with UM 44e.
        (c) Periodic tests and quality assurance inspections.
        Under the procedures set forth in 24 CFR 200.935(d)(8) concerning 
    periodic tests and quality assurance inspections, the frequency of 
    testing for a product shall be described in the specific building 
    product certification program. In the case of carpet and carpet with 
    attached cushion, testing and inspection shall be conducted as follows:
        (1) Two samples of each certified quality shall be taken every six 
    months from the manufacturer and one sample annually from the public 
    marketplace for testing in a laboratory accredited by the National 
    Voluntary Laboratory Accreditation Program (NVLAP) of the U.S. 
    Department of Commerce.
        (2) The administrator shall also review the quality procedures 
    twice a year to assure that they are being followed by the 
    manufacturer.
        (d) Cut pile polypropylene carpet. Provisions for cut pile 
    polypropylene are included under UM 44e.
        8. Section 200.943 is revised to read as follows:
    
    
    Sec. 200.943  Supplementary specific requirements under the HUD 
    building product standards and certification program for the 
    grademarking of lumber.
    
        (a) Applicable Standard. (1) In accordance with UM 38j, lumber 
    shall be grademarked in compliance with the U.S. Department of Commerce 
    Voluntary Product Standard PS-20-94 American Softwood Lumber Standard.
        (2) This standard has been approved by the Director of the Federal 
    Register for incorporation by reference in accordance with 5 U.S.C. 
    552(a) and 1 CFR part 51. It is available from U.S. Department of 
    Commerce, American Lumber Standard Committee (ALSC), P.O. Box 210, 
    Germantown, Maryland 20875-0210.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6) concerning labeling of a product, the administrator's 
    validation mark and the manufacturer's certification of compliance with 
    the applicable standard are required on the certification label issued 
    by the administrator to the manufacturer. The certification mark shall 
    be affixed to each piece of lumber. In the case of grademarking of 
    lumber, the following information shall be included on the 
    certification label or mark:
        (1) The registered symbol which identifies the grading agency;
        (2) Species or species combination;
        (3) Grade;
        (4) Identification of the applicable grading rules when not 
    indicated by the species identification or agency symbol;
        (5) Mill or grader;
        (6) For members which are less than 5 inches in nominal thickness, 
    indication that the lumber was green or dry at the time of dressing; 
    and
        (7) Indication that the lumber was finger jointed.
        (c) Periodic tests and quality assurance. Periodic tests and 
    quality assurance inspections shall be carried out by the American 
    Lumber Standard Committee as defined in PS 20-94.
        9. Section 200.944 is revised to read as follows:
    
    
    Sec. 200.944  Supplementary specific requirements under the HUD 
    building product standards and certification program for plywood and 
    other wood-based structural-use panels.
    
        (a) Applicable standards. (1) All plywood prescriptively designed, 
    manufactured, and tested shall be in compliance with the U.S. 
    Department of Commerce Voluntary Product Standard PS 1-95. Plywood 
    panels not meeting the grade requirements of PS 1-95 and all composite 
    and non-veneer structural-use panels shall comply with the 
    ``Performance Standards and Policies for Structural-Use Panels-94'' 
    (APA Standard PRP 108-94 or TECO Standard PRP 133-94) except that the 
    American Society for Testing and Materials (ASTM) Standard ASTM D 3043-
    87 Method B may be used.
        (2) These standards have been approved by the Director of the 
    Federal Register for incorporation by reference in accordance with 5 
    U.S.C. 552(a) and 1 CFR part 51. They are available from the U.S. 
    Department of Commerce, NIST, Gaithersburg, MD 20899; APA-The 
    Engineered Wood Association, 7011 South 19th St., Tacoma, WA 98411; 
    TECO/PFS Inc., 2402 Daniels Street, Madison, WI 53704; American Society 
    for Testing and Materials (ASTM), 100 Barr Harbor Drive, West 
    Conshohocken, Pennsylvania 19428.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6) concerning labeling of a product, the administrator's 
    validation mark and the manufacturer's certification of compliance with 
    the applicable standards are required to be on the certification label 
    issued by the administrator to the manufacturer. All plywood panels 
    made to PS 1-95 prescriptive or performance standards shall be marked 
    as complying to PS 1-95. All plywood products not meeting the 
    requirements of PS 1-95 and all composite and non-veneer structural-use 
    panels that do not comply with APA PRP 108-94 or TECO PRP 133-94 shall 
    be marked as complying with UM 40c. The label shall be located on each 
    panel so that it is available for inspection. The label shall include 
    the manufacturer's name and mill number.
        (c) Periodic tests and quality assurance. Under the procedures 
    concerning periodic tests and quality assurance inspections, the 
    frequency of testing for a product shall be described in the specific 
    building product certification program. In the case of plywood and 
    other wood-based structural-use panels, testing and inspection shall be 
    conducted as follows:
        (1) At least three times a year, the administrator shall visit the 
    manufacturer's facility to select 10 panels of each certified product 
    for testing in a laboratory accredited by the National Voluntary 
    Laboratory Accreditation Program (NVLAP) of the U.S. Department of 
    Commerce.
        (2) The administrator shall also review the quality assurance 
    procedures three times a year to assure that they are being followed by 
    the manufacturer.
        10. Section 200.948 is revised to read as follows:
    
    
    Sec. 200.948  Supplementary specific requirements under the HUD 
    building product standards and certification program for carpet 
    cushion.
    
        (a) Applicable standards. (1) All carpet cushion shall be designed, 
    manufactured, and tested in compliance with the following standards:
        (i) ASTM D3574-95 Test Method for Flexible Cellular Materials;
        (ii) ASTM D297-95 Standard Test Method for Rubber Products Chemical 
    Analysis;
        (iii) ASTM D629-95 Test Methods for Quantitative Analysis of 
    Textiles;
        (iv) ASTM D1667-90 Specification for Flexible Cellular Materials;
        (v) ASTM D2646-95 Test Method for Backing Fabrics;
        (vi) ASTM D3696-90 Test Method for Delamination of Secondary 
    Backing of Pile Coverings.
        (2) These standards have been approved by the Director of the 
    Federal Register for incorporation by reference in accordance with 5 
    U.S.C. 552(a) and
    
    [[Page 27490]]
    
    1 CFR part 51. They are available from the American Society for Testing 
    and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, 
    Pennsylvania 19428.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6) concerning labeling of a product, the administrator's 
    validation mark and the manufacturer's certification of compliance with 
    the applicable standards are required to be on the certification label 
    issued by the administrator to the manufacturer. Each carpet cushion 
    shall be marked as to type and class, and as conforming to UM 72b.
        (c) Periodic tests and quality assurance. Under the procedures set 
    forth in 200.935(d)(8), testing and inspection shall be conducted as 
    follows:
        (1) At least twice a year, the administrator shall visit the 
    manufacturer's facility to select a sample of each certified carpet 
    cushion for testing by a laboratory approved by the administrator.
        (2) The administrator shall review the quality assurance procedures 
    every six months to assure that they are being followed by the 
    manufacturer.
        11. A new Sec. 200.951 is added to read as follows:
    
    
    Sec. 200.951  Supplementary specific requirements under the HUD 
    building product standard and certification program for elastomeric 
    joint sealants.
    
        (a) Applicable standards. (1) All elastomeric joint sealants shall 
    be designed, manufactured, and tested in compliance with the following 
    American Society for Testing and Materials standards:
        (i) ASTM C920-94  Standard Specification for Elastomeric Joint 
    Sealants, except that there be a maximum of 25% loss of elongation when 
    determined after curing and 2500 hours of ultra-violet light in a xenon 
    arc accelerated weathering test for Class 25 materials compared to a 
    cured non-exposed sample;
        (ii) ASTM C1193-91  Standard Guide for the Use of Elastomeric 
    Sealants.
        (2) These standards have been approved by the Director of the 
    Federal Register for incorporation by reference in accordance with 5 
    U.S.C. 552(a) and 1 CFR part 51. They are available from the American 
    Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West 
    Conshohocken, Pennsylvania 19428.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6) concerning labeling of a product, the administrator's 
    validation mark and the manufacturer's certification of compliance with 
    the applicable standards are required to be on the certification label 
    issued by the administrator to the manufacturer. Each container of 
    elastomeric joint sealant shall include the sealant's type, grade, 
    class, and use, and the manufacturer's name, plant location and 
    statement of compliance with UM 105.
        (c) Periodic tests and quality assurance inspections. Under the 
    procedures set forth in 24 CFR 200.935(d)(8) concerning periodic tests 
    and quality assurance inspections, the frequency of testing for a 
    product shall be described in the specific building product 
    certification program. In the case of elastomeric joint sealants, 
    testing and inspection shall be conducted as follows:
        (1) At least once every year, the administrator shall visit the 
    manufacturer's facility to select a sample for testing in a laboratory 
    accredited by the National Voluntary Laboratory Accreditation Program 
    (NVLAP) of the U.S. Department of Commerce.
        (2) The administrator shall also review the quality assurance 
    procedures once a year to assure that they are being followed by the 
    manufacturer.
        12. A new Sec. 200.952 is added to read as follows:
    
    
    Sec. 200.952  Supplementary specific requirements under the HUD 
    building product standards and certification program for interior 
    particleboard stair treads.
    
        (a) Applicable standards. (1) All interior particleboard stair 
    treads shall be designed, manufactured, and tested in compliance with 
    ANSI A208.1 Mat-Formed Wood Particleboard, Grade M-3.
        (2) This standard has been approved by the Director of the Federal 
    Register for incorporation by reference in accordance with 5 U.S.C. 
    552(a) and 1 CFR part 51, and is available from the American National 
    Standards Institute, Inc., 11 West 42nd Street, New York, New York 
    10036.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6) concerning labeling of a product, the administrator's 
    validation mark and the manufacturer's certification of compliance with 
    the applicable standard are required to be on the certification label 
    issued by the administrator to the manufacturer. Each interior 
    particleboard stair tread shall include the manufacturer's statement of 
    conformance to UM 70b, a statement that this product is for interior 
    use only, and the manufacturer's name and plant location.
        (c) Periodic tests and quality assurance. Under the procedures set 
    forth in 24 CFR 200.935(d)(8) concerning periodic tests and quality 
    assurance inspections, the frequency of testing for a product shall be 
    described in the specific building product certification program. In 
    the case of interior particleboard stair treads, testing and inspection 
    shall be conducted as follows:
        (1) At least once every three months, the administrator shall visit 
    the manufacturer's facility to select a sample for testing in a 
    laboratory approved by the administrator.
        (2) The administrator shall also review the quality assurance 
    procedures twice a year to assure that they are being followed by the 
    manufacturer.
        13. A new Sec. 200.953 is added to read as follows:
    
    
    Sec. 200.953  Supplementary specific requirements under the HUD 
    building product standards and certification program for sprayed 
    polyurethane foam for roof insulation.
    
        (a) Applicable standards. (1) All sprayed polyurethane foam for 
    roof insulation shall be designed, manufactured, and tested in 
    compliance with ASTM C1029-93 Standard Specification for Spray Applied 
    Rigid Cellular Polyurethane Thermal Insulation. The foam shall be 
    installed in accordance with ASTM D5469-93 Standard Guide for 
    Application of New Spray Applied Polyurethane Foam and Coated Roofing 
    Systems, and designed in accordance with the Society of the Plastics 
    Industry (SPI) standard PFCD AY 104-90 Recommended Design 
    Considerations and Guide Specifications.
        (2) These standards have been approved by the Director of the 
    Federal Register for incorporation by reference in accordance with 5 
    U.S.C. 552(a) and 1 CFR part 51. They are available from the American 
    National Standards Institute, Inc., 11 West 42nd Street, New York, New 
    York 10036, or the Society of the Plastics Industry (SPI), 1275 K 
    Street, NW, Suite 400, Washington, D.C., 20005.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6) concerning labeling of a product, the administrator's 
    validation mark and the manufacturer's certification of compliance with 
    the applicable standard are required to be on the certification label 
    issued by the administrator to the manufacturer. Each container or 
    package of sprayed polyurethane foam roof insulation
    
    [[Page 27491]]
    
    material shall be marked as conforming to UM 110. The label shall 
    include the manufacturer's name and plant location.
        (c) Periodic tests and quality assurance inspections. Under the 
    procedures set forth in 24 CFR 200.935(d)(8) concerning periodic tests 
    and quality assurance inspections, the frequency of testing for a 
    product shall be described in the specific building product 
    certification program. In the case of sprayed polyurethane foam for 
    room insulation, testing and inspection shall be conducted as follows:
        (1) At least twice a year, the administrator shall visit the 
    manufacturer's facility to select a sample for testing in an approved 
    laboratory with the applicable standard.
        (2) The administrator shall also review the quality assurance 
    procedures twice a year to assure that they are being followed by the 
    manufacturer.
        14. A new Sec. 200.954 is added to read as follows:
    
    
    Sec. 200.954  Supplementary specific requirements under the HUD 
    building product standard and certification program for flooring 
    adhesives.
    
        (a) Applicable Standards. (1) All construction adhesives for field 
    glued wood floor systems shall be designed, manufactured, and tested in 
    compliance with the following American Society for Testing and 
    Materials (ASTM) standard D3498-93 Specifications for Adhesive for 
    Field-Gluing Plywood to Lumber Framing for Floor Systems except that 
    the mold and bacteria resistance tests shall not be included.
        (2) This standard has been approved by the Director of the Federal 
    Register for incorporation by reference in accordance with 5 U.S.C. 
    552(a) and 1 CFR part 51, and is available from the American Society 
    for Testing & Materials Inc., 100 Barr Harbor Drive, West Conshohocken, 
    PA. 19428.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6) concerning labeling of a product, the Administrator's 
    validation mark and the manufacturer's certification of compliance with 
    the applicable standard are required to be on the certification label 
    issued by the Administrator to the manufacturer. Each container shall 
    be marked as being in compliance with UM 60a. The label shall also 
    include the manufacturer's name, plant location, and shelf life.
        (c) Periodic Tests and Quality Assurance. Under the procedures set 
    forth in 24 CFR 200.935(d)(8) concerning periodic tests and quality 
    assurance inspections, the frequency of testing for a product shall be 
    described in the specific building product certification program. In 
    the case of construction adhesives for field glued wood floor systems, 
    testing and inspection shall be conducted as follows:
        (1) At least every six months, the administrator shall visit the 
    manufacturer's facility to select a sample for testing in a laboratory 
    approved by the administrator.
        (2) The administrator shall also review the quality assurance 
    procedures twice a year to assure that they are being followed by the 
    manufacturer.
        15. A new Sec. 200.955 is added to read as follows:
    
    
    Sec. 200.955  Supplementary specific requirements under the HUD 
    building product standard and certification program for fenestration 
    products (windows and doors).
    
        (a) Applicable Standards. (1) All windows and doors shall be 
    designed, manufactured, and tested in compliance with American 
    Architectural Manufacturers Association (AAMA) standard, AAMA 101/
    I.S.2-97, Voluntary Specifications for Aluminum, Vinyl (PVC), and Wood 
    Windows and Glass Doors.
        (2) This standard has been approved by the Director of the Federal 
    Register for incorporation by reference in accordance with 5 U.S.C. 
    552(a) and 1 CFR part 51, and is available from the American 
    Architectural Manufacturers Association, 1540 East Dundee Road, 
    Paletine, IL 60067.
        (b) Labeling. Under the procedures set forth in 24 CFR 
    200.935(d)(6) concerning labeling of a product, the administrator's 
    validation mark and the manufacturer's certification of compliance with 
    the applicable standards are required to be on the certification label 
    issued by the administrator to the manufacturer. Each window or glass 
    door shall include the manufacturer's name, plant location, and 
    statement of compliance with UM 111.
        (c) Periodic Tests and Quality Assurance Inspections. Under the 
    procedures set forth in 24 CFR 200.935(d)(8) concerning periodic tests 
    and quality assurance inspections, the frequency of testing for a 
    product shall be described in the specific building product 
    certification program. In the case of windows and glass doors, testing 
    and inspection shall be conducted as follows:
        (1) At least once every four years, the administrator shall visit 
    the manufacturer's facility to select a commercial sample for testing 
    in a laboratory approved by the administrator.
        (2) The administrator shall also review the quality assurance 
    procedures twice a year to assure that they are being followed by the 
    manufacturer.
    
        Dated: March 7, 1997.
    Nicolas P. Retsinas,
    Assistant Secretary for Housing-Federal Housing Commissioner
    [FR Doc. 97-13048 Filed 5-16-97; 8:45 am]
    BILLING CODE 4210-27-P
    
    
    

Document Information

Published:
05/19/1997
Department:
Housing and Urban Development Department
Entry Type:
Proposed Rule
Action:
Proposed rule.
Document Number:
97-13048
Pages:
27486-27491 (6 pages)
Docket Numbers:
Docket No. FR-4137-P-01
RINs:
2502-AG84: Changes in the Minimum Property Standards; Technical Suitability of Products Program (FR-4137)
RIN Links:
https://www.federalregister.gov/regulations/2502-AG84/changes-in-the-minimum-property-standards-technical-suitability-of-products-program-fr-4137-
PDF File:
97-13048.pdf
CFR: (14)
1 CFR 200.951
1 CFR 200.952
1 CFR 200.953
1 CFR 200.954
1 CFR 200.955
More ...