01-11567. Virginia Electric and Power Company, North Anna Power Station Units 1 and 2; Exemption  

  • Start Preamble

    1.0 Background

    The Virginia Electric and Power Company (the licensee) is the holder of Facility Operating Licenses NPF-4 and NPF-7, which authorize operation of the North Anna Power Station, Units 1 and 2. The licenses provide, among other things, that the facility is subject to all rules, regulations, and orders of the U.S. Nuclear Regulatory Commission (NRC, the Commission) now or hereafter in effect.

    The facility consists of two pressurized-water reactors located in Louisa County in the Commonwealth of Virginia.

    2.0 Purpose

    Title 10 of the Code of Federal Regulations (10 CFR) part 50, Appendix G requires that pressure-temperature (P-T) limits be established for reactor pressure vessels (RPVs) during normal operating, and hydrostatic pressure or leak testing conditions. Specifically, 10 CFR part 50, Appendix G states that “[t]he appropriate requirements on * * * the pressure-temperature limits and minimum permissible temperature must be met for all conditions.” Appendix G of 10 CFR part 50 specifies that the requirements for these limits are the American Society of Mechanical Engineers (ASME) Code, Section XI, Appendix G Limits. RG 1.99, Rev. 2, provides guidance for implementing 10 CFR Part 50, Appendix G. In GL 88-11, the NRC staff advised licensees that the staff would use RG 1.99, Rev. 2, to review P-T limit curves. RG 1.99, Rev. 2, contains conservative methodologies for determining the increase in transition temperature and the decrease in upper-shelf energy resulting from neutron radiation.

    To address provisions of amendments to the technical specifications (TS) regarding the P-T limits, low temperature overpressure protection (LTOP) system setpoints, and LTOP system effective temperature (Tenable), the licensee requested in its submittal dated June 22, 2000, as supplemented by letters dated September 19, 2000, and January 4, February 14, March 13, March 22, and April 11, 2001, that the staff exempt North Anna Units 1 and 2 from application of specific requirements of 10 CFR part 50, appendix G, and substitute use of ASME Code Case N-641. Code Case N-641 permits the use of an alternate reference fracture toughness (KIC fracture toughness curve instead of KIa fracture toughness curve) for reactor vessel materials in determining the P-T limits, LTOP system setpoints and Tenable, and provides for plant-specific evaluation of Tenable. Since the KIC fracture toughness curve shown in ASME Section XI, Appendix A, Figure A-2200-1 (the KIC fracture toughness curve) provides greater allowable fracture toughness than the corresponding KIa fracture toughness curve of ASME Section XI, Appendix G, Figure G-2210-1 (the KIa fracture toughness curve) and a plant-specific evaluation of Tenable would give lower values of Tenable than use of a generic bounding evaluation for Tenable, use of Code Case N-641 for establishing the P-T limits, LTOP system setpoints and Tenable would be less conservative than the methodology currently endorsed by 10 CFR Part 50, Appendix G and, therefore, an exemption to apply the Code Case would be required by 10 CFR 50.60. Although the use of the KIC fracture toughness curve in ASME Code Case N-641 was recently incorporated into appendix G to Section XI of the ASME Code, an exemption is still needed because 10 CFR part 50, appendix G requires the licensee's analysis to use an edition and addenda of Section XI of the ASME Code incorporated by reference into 10 CFR 50.55a, i.e., the editions through 1995 and addenda through the 1996 addenda (which do not include the provisions of Code Case N-641).

    The proposed amendments submitted by the licensee will revise the P-T limits of TS 3/4.4.9 related to the heatup and cooldown of the reactor coolant system (RCS), the LTOP system setpoints and Tenable for the LTOP system, for operation to 32.3 effective full power years (EFPY) for Unit 1 and 34.3 EFPY for Unit 2.

    ASME Code Case N-641

    The licensee has proposed an exemption to allow use of ASME Code Case N-641 in conjunction with ASME Section XI, 10 CFR 50.60(a) and 10 CFR part 50, appendix G, to determine the P-T limits, LTOP system setpoints and Tenable.

    The proposed amendments to revise the P-T limits, LTOP system setpoints and Tenable for North Anna Units 1 and 2 rely in part on the requested exemption. The revised P-T limits, LTOP system setpoints and Tenable have been developed using the KIc fracture toughness curve, in lieu of the KIa fracture toughness curve, as the lower bound for fracture toughness of the RPV materials.

    Use of the KIc curve in determining the lower bound fracture toughness of RPV steels is more technically correct than use of the KIa curve since the rate of loading during a heatup or cooldown is slow and is more representative of a static condition than a dynamic condition. The KIc curve appropriately implements the use of static initiation fracture toughness behavior to evaluate the controlled heatup and cooldown process of a reactor vessel. The staff has required use of the conservatism of the KIa curve since 1974, when the curve was adopted by the ASME Code. This conservatism was initially necessary due to the limited knowledge of the fracture toughness of RPV materials at that time. Since 1974, additional knowledge has been gained about RPV materials, which demonstrates that the lower bound on fracture toughness provided by the KIa curve greatly exceeds the margin of safety required to protect the public health and safety from potential RPV failure. In addition, P-T curves, LTOP setpoints, and Tenable based on the KIc curve will enhance overall plant safety by opening the P-T operating window, with the greatest safety benefit in the region of low temperature operations.

    Since an unnecessarily reduced P-T operating window can reduce operator flexibility without just basis, implementation of the proposed P-T curves, LTOP setpoints, and Tenable as allowed by ASME Code Case N-641 may result in enhanced safety during critical plant operational periods, specifically heatup and cooldown conditions. Thus, pursuant to 10 CFR 50.12(a)(2)(ii), the underlying purpose of 10 CFR 50.60 and appendix G to 10 CFR part 50 will continue to be served.

    In summary, the ASME Section XI, Appendix G, procedure was conservatively developed based on the level of knowledge existing in 1974 concerning RPV materials and the estimated effects of operation. Since 1974, the level of knowledge about these topics has been greatly expanded. The staff concurs that this increased knowledge permits relaxation of the ASME Section XI, Appendix G requirements by application of ASME Code Case N-641, while maintaining, Start Printed Page 23279pursuant to 10 CFR 50.12(a)(2)(ii), the underlying purpose of the NRC regulations to ensure an acceptable margin of safety.

    3.0 Discussion

    Pursuant to 10 CFR 50.12, the Commission may, upon application by any interested person or upon its own initiative, grant exemptions from the requirements of 10 CFR Part 50, when (1) the exemptions are authorized by law, will not present an undue risk to public health or safety, and are consistent with the common defense and security; and (2) when special circumstances are present. The staff accepts the licensee's determination that an exemption would be required to approve the use of Code Case N-641. The staff examined the licensee's rationale to support the exemption request and concurs that the use of the Code case would meet the underlying intent of these regulations. Based upon a consideration of the conservatism that is explicitly incorporated into the methodologies of 10 CFR part 50, appendix G; Appendix G of the Code; and Regulatory Guide 1.99, Revision 2, as discussed above, the staff concludes that application of the Code case as described would provide an adequate margin of safety against brittle failure of the RPV. This conclusion is also consistent with the determinations that the staff has reached for other licensees under similar conditions based on the same considerations.

    Therefore, the staff concludes that granting an exemption under the special circumstances of 10 CFR 50.12(a)(2)(ii) is appropriate and that the methodologies of Code Case N-641 may be used to revise the P-T limits, LTOP setpoints, and Tenable for North Anna Power Station, Units 1 and 2.

    4.0 Conclusion

    Accordingly, the Commission has determined that, pursuant to 10 CFR 50.12(a), the exemption is authorized by law, will not endanger life or property or common defense and security, and is, otherwise, in the public interest. Therefore, the Commission hereby grants the licensee an exemption from the requirements of 10 CFR part 50, appendix G, for North Anna Power Station, Units 1 and 2.

    Pursuant to 10 CFR 51.32, the Commission has determined that the granting of this exemption will not have a significant effect on the quality of the human environment (66 FR 22018).

    This exemption is effective upon issuance.

    Start Signature

    Dated at Rockville, Maryland, this 2nd day of May 2001.

    For the Nuclear Regulatory Commission.

    John A. Zwolinski,

    Director, Division of Licensing Project Management, Office of Nuclear Reactor Regulation.

    End Signature End Preamble

    [FR Doc. 01-11567 Filed 5-7-01; 8:45 am]

    BILLING CODE 7590-01-P