NUCLEAR REGULATORY COMMISSION
[Docket No. 030-32190; License No. 49-27356-01 EA 93-238]
Western Industrial X-Ray Inspection Company, Inc., Evanston,
Wyoming; Order Suspending License (Effective Immediately) and Demand
for Information
I
Western Industrial X-Ray Inspection Company, Inc. (Licensee or WIX)
is the holder of Byproduct Material License No. 49-27356-01 issued by
the Nuclear Regulatory Commission (NRC or Commission) pursuant to 10
CFR Parts 30 and 34. The license authorizes the Licensee to possess
sealed sources of iridium-192 in various radiography devices for use in
performing industrial radiography activities. The license, originally
issued on August 12, 1991, is due to expire on August 31, 1996.
II
In April 1993 and in January and March 1994, the NRC conducted
inspections and investigations of Western Industrial X-Ray Inspection
Company, Inc., at the company's offices in Evanston, Wyoming, and at
temporary job sites near Granger, Wyoming. These inspections and
investigations identified numerous violations of NRC's radiation safety
requirements, including some violations which were found to have
recurred after being found in previous inspections. These violations
were described in inspection reports 030-32190/93-01 and 030-32190/94-
01 issued on May 12, 1994. In addition, based on the investigations
conducted by the Office of Investigations (OI), several of the
violations have been determined by the NRC to have been committed
deliberately by Licensee employees.
In a March 2, 1994, letter to the Licensee, the NRC described the
apparent violations that had been identified as of that date and
confirmed the arrangements for the Licensee to attend an enforcement
conference in the NRC's Arlington, Texas office. The enforcement
conference, which was transcribed, occurred on April 1, 1994. The
Licensee was represented by Mr. Larry D. Wicks, who is the president
and owner of WIX as well as the company's designated radiation safety
officer (RSO).
The most significant of the NRC's concerns, and many of the
violations, are related to a July 31, 1993, incident involving a WIX
radiographer and radiographer's assistant who were performing
radiography on a pipeline near LaBarge, Wyoming. The incident involved
a radiographic device containing a 37-curie, sealed iridium-192 source
and resulted in a potentially significant radiation exposure to the
radiographer's assistant.
This incident was reviewed during the inspection and investigation
that began in January 1994. The following information regarding this
incident is based on joint interviews conducted by the inspector and
investigator; on signed, sworn statements taken by the investigator
during these interviews; and on statements made by Mr. Wicks at the
April 1 enforcement conference. With the exception of certain
statements made by Mr. Wicks at the enforcement conference, which are
noted below, all other statements were made to the inspector and
investigator during their joint interviews of WIX personnel.
The radiographer admitted that he violated NRC requirements by not
observing the assistant as she radiographed welds and moved equipment
from one location to another (in a later statement, the radiographer
said he was aware he was responsible for the assistant but not aware
that he had to observer performing radiographic operations 100% of the
time). The assistant admitted that she violated NRC requirements by not
performing a radiation survey after each radiographic exposure and by
not locking the sealed radioactive source in the radiography device
prior to moving equipment to another weld. The assistant stated further
that after moving the equipment to another weld she noticed her survey
instrument was ``pegged,'' an that her self-reading pocket dosimeter
was off-scale, both indications that the device's radioactive source
had not been returned to its fully shielded position or had been
jostled from its shielded position when the device was moved. The
assistant stated that her alarm ratemeter, a protective device which is
set to alarm in a radiation field of 500 millirem/hour, did not alarm
but added that it was probably turned off. Both she and the
radiographer stated that she immediately brought this incident to the
radiographer's attention an that he ``cranked'' the source into the
device and locked it, and that they stopped work for the day.
Both the assistant and the radiographer stated that they prepared
incident reports for their employer, Larry Wicks, the company president
an RSO, and that the incident reports were false in that they falsely
stated that the radiographer and the assistant were working together at
the time of the incident and falsely stated that they had surveyed the
device and locked the source in the device prior to its being moved.
The Assistant claimed that she told Mr. Wicks at the time the reports
were turned in that the incident reports were false, but Mr. Wicks
denied this claim during interviews with the inspector and investigator
and at the enforcement conference, stating that he did not know the
incident reports were false until brought to his attention by the NRC.
Mr. Wicks stated during the investigation and at the enforcement
conference that after learning of the incident he sent the assistant's
thermoluminescent dosimeter (TLD) in for immediate processing along
with other TLDs worn by company personnel during the month of July
1993. Mr. Wicks also stated that all of the TLDs were sent in the same
package. However, the company that processes TLSs for WIX, Laudauer,
Inc., stated, through its representative, to NRC personnel that while
it had received TLDs from WIX for other employees for the month of July
1993, it had no record of receiving a TLD for the assistant for the
month of July 1993 and no record of receiving a request from Mr. Wicks
for immediate processing of any TLDs sent in for that month. Exposure
records mailed by Landauer to WIX and retained by WIX contain no
information regarding the assistant's exposure for the month of July
1993 (her exposure records for all other months are available). The
assistant, whom Mr. Wicks placed on restricted duty pending a
determination of their exposure, also told NRC personnel that she
persisted in trying to obtain from Mr. Wicks her exposure record for
the month of July and that Mr. Wicks eventually--about three weeks
after the incident--told her that she had received 350 millirem.
Mr. Wicks stated during the investigation, however, that he never
provided the assistant an exposure estimate based on Landauer's
processing of the TLD because he did not have such a number to give
her. The only explanation he has offered for not pursuing the question
of her July 1993 exposure is that he was very busy. Despite the
occurrence of the following events, Mr. Wicks has stated that he was
not reminded of the need to evaluate the assistant's exposure from the
incident or for the month of July 1993: (1) Placing the assistant on
restricted duty from the date of the incident (July 31, 1993) until she
left his employ in September 1993; (2) receiving Landauer reports for
July 1993 which contained no exposure records for the assistant even
though, according to Mr. Wicks' statement, he had sent in her TLD for
immediate emergency processing; (3) preparing a summary of the
assistant's radiation exposure history for her employer, which included
the period in question (July 1993); and (4) responding in the fall of
1993 to a request from the NRC for the radiation exposure reports of
terminated employees. In responding to the latter request, Mr. Wicks
did not provide a report for the radiographer's assistant despite
having provided one for her husband, whose termination date occurred
five days after hers. As of the time of the inspection and
investigation in January 1994, Mr. Wicks had not performed an adequate
evaluation to determine the assistant's exposure resulting from the
July 31, 1993 incident. After further requests from the NRC, Mr. Wicks
submitted on March 8, 1994, an estimate of 6 rems for the assistant's
whole body exposure and at the enforcement conference characterized
that estimate as ``pure and simply a guess,'' noting that ``I had to
have something to send you.''
Based on its inspection and investigation of the July 31, 1993
incident, as well as the information obtained during the enforcement
conference, the NRC has concluded that the Licensee and its employees
violated NRC requirements by failing to: (1) perform an evaluation of
the assistant's radiation exposure to ensure compliance with NRC
limits, as required by 10 CFR 20.201, and send the assistant's TLD in
for immediate processing when her pocket dosimeter had gone off-scale,
as required by 10 CFR 34.33(d); (2) check the alarm function on alarm
ratemeters prior to the start of each shift, as required by 10 CFR
34.33(f)(1); (3) perform a radiation survey of a radiography device
following each exposure, as required by 10 CFR 34.43(b); (4) lock the
sealed radioactive source in the device after each exposure, as
required by 10 CFR 34.22(a); (5) ensure that radiographers supervise
assistant radiographers who are performing radiographers operations, as
required by 10 CFR 34.44, a repeat violation in that it occurred in
July 1993, was discussed during the inspection in January 1994, and was
found again in March 1994; (6) provide NRC a report of an individual's
radiation exposure following the individual's termination of
employment, as required by 10 CFR 20.408(b); and (7) ensure that alarm
ratemeters worn by radiography personnel were calibrated at a one-year
frequency, as required by 34.33(f)(4), a repeat violation in that it
was found and discussed with Mr. Wicks following the inspection and
investigation in April 1993, recurred in July 1993 and was found again
in January 1994.
Other violations found during the NRC's inspections and
investigations, but unrelated to the July 1993 incident, include the
Licensee's failure to: (1) ensure that pocket dosimeters worn by
radiography personnel were checked for correct response to radiation at
12-month intervals, as required by 10 CFR 34.33(c), a violation that
occurred on January 18, 1994, 13 days after the inspector had informed
the RSO that he should remove uncalibrated dosimeters from service; (2)
perform and record quarterly audits of radiography personnel for all
calendar quarters in 1992, as required by license condition; (3)
maintain constant surveillance and immediate control of licensed
material in March 1993, as required by 10 CFR 20.207; (4) submit to the
NRC a quality assurance program for use of shipping containers, as
required by 10 CFR 71.12(b), a repeat violation in that it was cited in
1992 and had not been corrected by January 1994; and (5) leak test
sealed sources prior to removing them from storage and transferring
them to the manufacturer in April 1993 and December 1993, as required
by license condition.
The NRC has also concluded from its inspections and investigations
that Mr. Wicks and employees of WIX violated the provisions of 10 CFR
30.10, ``Deliberate Misconduct,'' a regulation which prohibits
individuals from deliberately causing a licensee to be in noncompliance
with NRC requirements and prohibits individuals from deliberately
providing materially false information to the NRC or a licensee.
Specifically, based on its review of the July 31, 1993 incident, its
review of the OI findings, and its review of the enforcement conference
transcript, the NRC has concluded that Mr. Wicks deliberately failed to
perform an evaluation of the assistant's radiation exposure; that Mr.
Wicks deliberately failed to send the assistant's TLD in for immediate
processing; that the radiographer deliberately failed to watch an
assistant perform radiography operations; and that the radiographer and
assistant deliberately provided materially false information to the
Licensee about the incident.
Based on its review of violations that were unrelated to the July
1993 incident, the NRC has concluded that Mr. Wicks deliberately failed
to perform and record quarterly audits of radiography personnel in
1992, because Mr. Wicks stated that he was aware of these requirements
and his responsibility to comply with them but failed to do so. The NRC
also has concluded that Mr. Wicks deliberately failed to ensure that
alarm ratemeters used by radiography personnel in March, April and July
1993 and January 1994 were calibrated at a one-year frequency, again
because Mr. Wicks stated that he was aware of these requirements and
his responsibility to comply with them but repeatedly failed to do so.
III
Based on the above, it appears that Licensee employees, including
the president and radiation safety officer, have engaged in deliberate
misconduct by deliberately violating NRC requirements that are
important to the protection of radiography personnel and the public and
have failed to ensure compliance with numerous requirements that are
important to the safe use of radiographic sources. Deliberate
violations of the nature described above cannot and will not be
tolerated by the NRC. Further, the history of numerous violations,
including repetitive violations, and the failure to follow through on
important safety issues, indicate that Mr. Wicks, who is the president
and radiation safety officer, is either incapable or unwilling to
ensure that the Licensee's radiography program is conducted in
accordance with all NRC requirements.
Consequently, I lack the requisite reasonable assurance that the
Licensee's current operations can be conducted under License No. 49-
27356-01 in compliance with the Commission's requirements and that the
health and safety of the public, including the Licensee's employees,
will be protected. Therefore, the public health, safety, and interest
require that License No. 49-27356-01 be suspended. Furthermore,
pursuant to 10 CFR 2.202, I find that the significance of the
violations and deliberate misconduct described above are such that the
public health, safety, and interest require that this Order be
immediately effective.
IV
Accordingly, pursuant to sections 81, 161b, 161i, 182 and 186 of
the Atomic Energy Act of 1954, as amended, and the Commission's
regulations in 10 CFR 2.202 and 10 CFR Parts 30 and 34, It is hereby
ordered, effective immediately, that license no. 49-27356-01 is
suspended pending further order.
The Regional Administrator, Region IV, may, in writing, relax or
rescind this order upon demonstration by the Licensee of good cause.
V
In accordance with 10 CFR 2.202, the Licensee must, and any other
person adversely affected by this Order may, submit an answer to this
Order, and may request a hearing on this Order, within 20 days of the
date of this Order. The answer may consent to this Order. Unless the
answer consents to this Order, the answer shall, in writing and under
oath or affirmation, specifically admit or deny each allegation or
charge made in this order and set forth the matters of fact and law on
which the Licensee or other person adversely affected relies and the
reasons as to why the Order should not have been issued. Any answer or
request for a hearing shall be submitted to the Secretary, U.S. Nuclear
Regulatory Commission, Attn: Chief, Docketing and Service Section,
Washington, DC 20555. Copies of the hearing request also should be sent
to the Director, Office of Enforcement, U.S. Nuclear Regulatory
Commission, Washington, DC 20555, to the Assistant General Counsel for
Hearings and Enforcement at the same address, to the Regional
Administrator, NRC Region IV, 611 Ryan Plaza Drive, Suite 400,
Arlington, Texas 76011, and to the Licensee if the hearing request is
by a person other than the Licensee. If a person other than the
Licensee requests a hearing, that person shall set forth with
particularity the manner in which his interest is adversely affected by
this Order and shall address the criteria set forth in 10 CFR 2.714(d).
If a hearing is requested by the Licensee or a person whose
interest is adversely affected, the Commission will issue an Order
designating the time and place of any hearing. If a hearing is held,
the issue to be considered at such hearing shall be whether this Order
should be sustained.
Pursuant to 10 CFR 2.202(c)(2)(i), the Licensee, or any other
person adversely affected by this Order, may, in addition to demanding
a hearing, at the time the answer is filed or sooner, move the
presiding officer to set aside the immediate effectiveness of the Order
on the ground that the Order, including the need for immediate
effectiveness, is not based on adequate evidence but on mere suspicion,
unfounded allegations, or error.
In the absence of any request for hearing, the provisions specified
in Section IV above shall be final 20 days from the date of this Order
without further order or proceedings. An answer or a request for
hearing shall not stay the immediate effectiveness of this order.
VI
In addition to issuance of this Order Suspending License No. 49-
27356-01, the Commission requires further information from the Licensee
in order to determine whether the Commission can have reasonable
assurance that in the future the Licensee will conduct its activities
in accordance with the Commission's requirements or, lacking such
assurance, whether the Commission should proceed to revoke the license.
Accordingly, pursuant to sections 161c, 161o, 182 and 186 of the
Atomic Energy Act of 1954, as amended, and the Commission's
requirements in 10 CFR 2.204 and 10 CFR 30.32(b), in order for the
Commission to determine whether License No. 49-27356-01 should be
revoked, or other enforcement action taken to ensure compliance with
NRC regulatory requirements, the Licensee is required to submit to the
Director, Office of Enforcement, U.S. Nuclear Regulatory Commission,
Washington, DC 20555, within 20 days of the date of this Order and
Demand for Information, the following information, in writing and under
oath or affirmation:
A. State way, in light of the violations and managerial failures
discussed in II and III above, NRC License No. 49-27356-01 should not
be revoked.
B. State why, in light of the facts described above, an order
should not be issued to Mr. Wicks as an individual prohibiting Mr.
Wicks from performing NRC-licensed activities. In addition, if an order
is not issued to prohibit Mr. Wicks from performing NRC-licensed
activities, then why should the NRC have confidence Mr. Wicks will
comply with Commission requirements.
Copies also shall be sent to the Assistant General Counsel for
Hearings and Enforcement at the same address, and to the Regional
Administrator, NRC Region IV, 611 Ryan Plaza Drive, Suite 400,
Arlington, Texas 76011-8064.
After reviewing your response, the NRC will determine whether
further action is necessary to ensure compliance with regulatory
requirements.
Dated at Rockville, Maryland this 16th day of June 1994.
For the Nuclear Regulatory Commission.
Hugh L. Thompson, Jr.,
Deputy Executive Director for Nuclear Materials Safety, Safeguards, and
Operations Support.
[FR Doc. 94-15486 Filed 6-24-94; 8:45 am]