C1-2014-14369. Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe Drinking Water Act; Analysis and Sampling Procedures
-
Start Preamble
Correction
In rule document 2014-14369, appearing on pages 35081 through 35096 in the issue of Thursday, June 19, 2014, make the following correction:
On page 35093, the table titled “ALTERNATIVE TESTING METHODS FOR CONTAMINANTS LISTED AT 40 CFR 141.852(a)(5)” should read as follows:Start Printed Page 36429
End PreambleAlternative Testing Methods for Contaminants Listed at 40 CFR 141.852(a)(5)
Organism Methodology category Method SM 20th, 21st editions 1 6 SM 22nd Edition 28 SM Online 3 Total Coliforms Lactose Fermentation Methods Standard Total Coliform Fermentation Technique 9221 B.1, B.2 9221 B.1, B.2-06. Enzyme Substrate Methods Colilert® 9223 B 9223 B-04. Colisure® 9223 B 9223 B-04. Colilert-18® 9223 B 9223 B 9223 B-04. Tecta EC/TC .33 Escherichia coli Escherichia coli Procedure (following Lactose Fermentation Methods) EC-MUG medium 9221 F.1 9221 F.1-06. Enzyme Substrate Methods Colilert® 9223 B 9223 B-04. Colisure® 9223 B 9223 B-04. Colilert-18® 9223 B 9223 B 9223 B-04. Tecta EC/TC.33 [FR Doc. C1-2014-14369 Filed 6-26-14; 8:45 am]
BILLING CODE 1505-01-D
Document Information
- Published:
- 06/27/2014
- Department:
- Environmental Protection Agency
- Entry Type:
- Rule
- Document Number:
- C1-2014-14369
- Pages:
- 36428-36429 (2 pages)
- Docket Numbers:
- EPA-HQ-OW-2014-0408, FRL-9912-52-OW
- PDF File:
- c1-2014-14369.pdf
- Supporting Documents:
- » 40 CFR Parts 141 and 142 National Primary Drinking Water Regulations: Revisions to the Total Coliform Rule; Final Rule. February 13, 2013
- » Veolia 2014b. Confirmation of Method Name and ATP Study
- » Memorandum from James L. Sinclair, Microbiologist 2014 dated April 9, 2014
- » TECTATM EC/TC medium and the TECTATM Instrument: a Presence/Absence Method for the Simultaneous Detection of Total Coliforms and Escherichia coli (E. coli) in Drinking Water.
- » Memorandum from Glynda Smith, Chemist, SRMD/TSC and Steve Wendelken, Chemist, SRMD/TSC, UEPA 2013c Palintest ATP Validation Summary and Method Review
- » Standard Methods for the Examination of Water and Wastewater 20th Edition 4500-ClO2 E
- » Chlorine Dioxide and Chlorite in Drinking Water by Amperometry using Disposable Sensors
- » Memorandum from Glynda Smith, Chemist, SRMD/TSC and Steve Wendelken, Chemist, SRMD/TSC, USEOPA 2013b Memorandum for Hach
- » Hach 2013b ATP Validation Report final
- » Standard Methods for the Examination of Water and Wastewater 4500-Cl G 20th Edition
- CFR: (1)
- 40 CFR 141