    Nebraska Public Power District; Cooper Nuclear Station 
    Environmental Assessment and Finding of No Significant Impact
    
    [Docket No. 50-298]
        The U.S. Nuclear Regulatory Commission (the Commission) is 
    considering the issuance of an exemption to Facility Operating License 
    No. DPR-46 to the Nebraska Public Power District (the licensee), for 
    the operation of the Cooper Nuclear Station (CNS), located in Nemaha 
    County, Nebraska.
    
    Environmental Assessment
    
    Identification of Proposed Action
    
        The proposed action would grant an exemption from the requirements 
    of Section III.C.1 of Appendix J to 10 CFR Part 50, to allow Type C 
    testing (local leak rate testing) of four containment isolation valves 
    in the reverse direction.
        The proposed action is in accordance with the licensee's 
    application for exemption dated June 29, 1994.
    
    The Need for the Proposed Action
    
        The purpose of Type C testing is to measure the leakage through the 
    primary reactor containment and thereby provide assurance that it does 
    not exceed the maximum allowable leakage rates. Prior to a recent 
    contractor review of local leakrate testing methodology, the licensee 
    had made the determination that reverse direction testing of the 
    subject containment isolation valves produced equivalent or more 
    conservative results than testing in the accident direction. The 
    contractor review disclosed that, while reverse pressure testing for 
    the subject valves (two globe valves and two stop-check globe valves) 
    was conservative with respect to measuring leakage past the valve 
    seating surfaces, such testing may be non-conservative with respect to 
    packing leakage and body-to-bonnet leakage. Packing and body-to-bonnet 
    leakage cannot be quantified by reverse pressure testing because the 
    physical configurations of the valves are such that valve packing and 
    the valve bonnets are not exposed to test pressure. The four valves are 
    not testable in the accident direction due to the inability to isolate 
    the valves from containment and the lack of test connections.
        Several factors are cited by the licensee in its June 29, 1994, 
    request for exemption to demonstrate that a high level of confidence 
    exists that reverse direction pressure testing does not yield 
    significantly different results than what would be expected in the 
    accident direction. First, reverse pressure testing of globe valves 
    generally results in a conservative seat leakage measurement because 
    the pressurization test applies force in the direction that would 
    unseat the disk. Any increase in leakage attributable to this factor 
    would tend to offset the inability to measure packing and body-to-
    bonnet leakage on the non-testable side of the valve. Second, all 
    subject valves are tested in the accident direction during integrated 
    leakrate tests, thus exposing all pressure retaining parts, including 
    the bonnet and packing, to the design basis pressure (58 psig).
        Third, integrated leakrate test results historically have not 
    indicated any significant leakage through these two paths. As of June 
    22, 1994, total minimum path as-left leakage for all type B and C tests 
    measured 117.95 standard cubic feet per hour. The 1991 integrated 
    leakrate test yielded a total measured leakrate of 102.5 standard cubic 
    feet per hour. These results demonstrate that significant margin exists 
    with respect to the startup limit of 189 standard cubic feet per hour 
    and the total allowable limit of 316 standard cubic feet per hour. 
    Thus, there is confidence that the requirements of 10 CFR part 50, 
    appendix J, and the Cooper Nuclear Station Technical Specifications 
    continue to be met.
        Fourth, valve packing and body-to-bonnet gaskets do not contain 
    materials that degrade as a result of the mild service conditions to 
    which they are subjected during normal operations and periodic 
    surveillance testing.
        Finally, while the above factors may provide reasonable assurance 
    that leakage through the bonnet and the packing is not a problem for 
    the four subject valves, the licensee has proposed additional actions 
    in order to justify permanent exemptions from the ``equivalent or more 
    conservative'' results requirement of 10 CFR Part 50, Appendix J. 
    Specifically the licensee proposes to perform soap bubble tests to 
    detect body-to-bonnet or packing leakage while these pressure retaining 
    boundaries are pressurized in the accident direction during future 
    integrated leakrate tests. A ``zero bubble'' or zero detectable leakage 
    acceptance criteria would be satisfied to demonstrate the leak-
    tightness of the packing and valve bonnets. Additionally, the licensee 
    proposes to specifically observe the two stop-check globe valves for 
    indication of leakage through the insulation during scheduled system 
    surveillance tests which subject the valves to pressurization.
        Without the proposed exemption, the licensee would be forced, at 
    significant cost but without any significant increase in public health 
    and safety, to implement plant modifications to permit local leakrate 
    testing with test pressure applied in the accident direction. Further, 
    such actions would delay the restart date of the current outage, which 
    is currently scheduled for July 11, 1994.
    
    Environmental Impacts of the Proposed Action
    
        The Commission has completed its evaluation of the proposed action 
    and concludes that the proposed exemption would allow permanent 
    individual exemptions from Appendix J to 10 CFR Part 50 to allow Type C 
    testing of four isolation valves in the reverse direction.
        The change will not increase the probability or consequences of 
    accidents, no changes are being made in the types of any effluents that 
    may be released offsite, and there is no significant increase in the 
    allowable individual or cumulative occupational radiation exposure. 
    Accordingly, the Commission concludes that there are no significant 
    radiological environmental impacts associated with the proposed action.
        With regard to potential nonradiological impacts, the proposed 
    action does involve features located entirely within the restricted 
    area as defined in 10 CFR Part 20. It does not affect nonradiological 
    plant effluents and has no other environmental impact. Accordingly, the 
    Commission concludes that there are no significant nonradiological 
    environmental impacts associated with the proposed action.
    
    Alternative to the Proposed Action
    
        Since the Commission concluded that there are no significant 
    environmental impacts associated with the proposed action, any 
    alternatives to the exemption will have either no environmental impact 
    or greater environmental impact.
        The principal alternative would be to deny the requested exemption. 
    Denial would not reduce the environmental impacts attributed to the 
    facility but would result in the expenditure of resources and increase 
    radiation exposures without any compensating benefit.
    
    Alternative Use of Resources
    
        This action does not involve the use of any resources not 
    previously considered in the Final Environmental Statement for the 
    Cooper Nuclear Station, dated February 1973.
    
    Agencies and Persons Consulted
    
        The NRC staff consulted with the Nebraska State official regarding 
    the environmental impact of the proposed action. The State official had 
    no comments.
    
    Finding of No Significant Impact
    
        Based upon the environmental assessment, the Commission concludes 
    that the proposed action will not have a significant effect on the 
    quality of the human environment. Accordingly, the Commission has 
    determined not to prepare an environmental impact statement for the 
    proposed action.
        For further details with respect to this action, see the request 
    for exemption dated June 29, 1994, which is available for public 
    inspection at the Commission's Public Document Room, 2120 L Street, 
    NW., Washington, DC 20555, and at the local public document room 
    located at the Auburn Public Library, 118 15th Street, Auburn, Nebraska 
    68305.
    
        Dated at Rockville, Maryland, this 8th day of July 1994.
    
        For the Nuclear Regulatory Commission.
    William D. Beckner,
    Director, Project Directorate IV-1, Division of Reactor Projects--III/
    IV, Office of Nuclear Reactor Regulation.
    [FR Doc. 94-17077 Filed 7-13-94; 8:45 am]