94-18302. Safety Standards for Underground Coal Mine Ventilation; Amendments  

  • [Federal Register Volume 59, Number 144 (Thursday, July 28, 1994)]
    [Unknown Section]
    [Page ]
    From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
    [FR Doc No: 94-18302]
    
    
    [Federal Register: July 28, 1994]
    
    
    =======================================================================
    -----------------------------------------------------------------------
    
    DEPARTMENT OF LABOR
    
    Mine Safety and Health Administration
    
    30 CFR Part 75
    
    RIN 1219-AA11
    
    
    Safety Standards for Underground Coal Mine Ventilation; 
    Amendments
    
    AGENCY: Mine Safety and Health Administration, Labor.
    
    ACTION: Final rule; technical amendments.
    
    -----------------------------------------------------------------------
    
    SUMMARY: This document makes technical amendments to the final rule for 
    safety standards for underground coal mine ventilation that appeared in 
    the Federal Register on May 15, 1992 (57 FR 20868).
    
    EFFECTIVE DATE: This regulation is effective July 28, 1994. The 
    incorporation by reference of certain publications listed in the 
    regulations is approved by the Director of the Federal Register as of 
    July 28, 1994.
    
    FOR FURTHER INFORMATION CONTACT: Patricia W. Silvey, Director, Office 
    of Standards, Regulations and Variances, MSHA, phone (703) 235-1910.
    
    SUPPLEMENTARY INFORMATION: On May 15, 1992, MSHA published a final rule 
    to revise its safety standards for underground coal mine ventilation. 
    This document makes nonsubstantive technical amendments to 
    Secs. 75.301, 75.333 (a), (d)(1), (e)(3) and (f) and 75.335 (a)(1)(iv) 
    and (a)(2). Sections 75.301, 75.333 (a), (d)(1), (e)(3) and (f) and 
    75.335 (a)(1)(iv) and (a)(2) are revised to include information 
    concerning the availability of the incorporated documents, where the 
    incorporated documents may be inspected, and the Federal Register 
    approval for incorporation by reference of the documents.
    
    List of Subjects in 30 CFR Part 75
    
        Incorporation by reference, Mine safety and health, Underground 
    coal mines, Ventilation.
    
        Dated: July 20, 1994.
    J. Davitt McAteer,
    Assistant Secretary for Mine Safety and Health.
    
    PART 75--MANDATORY SAFETY STANDARDS--UNDERGROUND COAL MINES
    
    Subpart D--Ventilation
    
        Accordingly, subpart D of part 75, subchapter O, chapter I, title 
    30 of the Code of Federal Regulations is corrected by making the 
    following technical amendments:
        1. The authority citation for Part 75 continues to read as follows:
    
        Authority: 30 U.S.C. 811, 957, and 961.
    
    
    Sec. 75.301  [Amended]
    
        2. In Sec. 75.301, the following definitions are revised to read as 
    follows:
    * * * * *
        Noncombustible Structure or Area. Describes a structure or area 
    that will continue to provide protection against flame spread for at 
    least 1 hour when subjected to a fire test incorporating an ASTM E119-
    88 time/temperature heat input, or equivalent. The publication ASTM 
    E119-88, ``Standard Test Methods for Fire Tests of Building 
    Construction and Materials'' is incorporated by reference and may be 
    inspected at any Coal Mine Health and Safety District and Subdistrict 
    Office, or at MSHA's Office of Standards, 4015 Wilson Boulevard, 
    Arlington, VA, and at the Office of the Federal Register, 800 North 
    Capitol Street, NW., Suite 700, Washington, DC. In addition, copies of 
    the document can be purchased from the American Society for Testing 
    Materials (ASTM), 1916 Race Street, Philadelphia, Pennsylvania 19103. 
    This incorporation by reference was approved by the Director of the 
    Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.
        Noncombustible Material. Describes a material which when used to 
    construct a ventilation control results in a control that will continue 
    to serve its intended function for 1 hour when subjected to a fire test 
    incorporating an ASTM E119-88 time/temperature heat input, or 
    equivalent. The publication ASTM E119-88, ``Standard Test Methods for 
    Fire Tests of Building Construction and Materials'' is incorporated by 
    reference and may be inspected at any Coal Mine Health and Safety 
    District and Subdistrict Office, or at MSHA's Office of Standards, 4015 
    Wilson Boulevard, Arlington, VA, and at the Office of the Federal 
    Register, 800 North Capitol Street, NW., Suite 700, Washington, DC. In 
    addition, copies of the document can be purchased from the American 
    Society for Testing Materials (ASTM), 1916 Race Street, Philadelphia, 
    Pennsylvania 19103. This incorporation by reference was approved by the 
    Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 
    1 CFR part 51.
    * * * * *
    
    
    Sec. 75.333  [Amended]
    
        3. In Sec. 75.333, paragraphs (a), (d)(1), (e)(3), and (f) are 
    revised to read as follows:
        (a) For purposes of this section; ``doors'' includes any 
    doorframes, and ``durable'' describes a material and construction 
    method that when used to construct a ventilation control results in a 
    control that is structurally equivalent to an 8-inch hollow-core 
    concrete block stopping with mortared joints as described in ASTM E72-
    80, ``Standard Methods of Conducting Strength Tests of Panels for 
    Building Construction'' (Section 12--Transverse Load--Specimen 
    Vertical). This publication is incorporated by reference and may be 
    inspected at any Coal Mine Health and Safety District and Subdistrict 
    Office, or at MSHA's Office of Standards, 4015 Wilson Boulevard, 
    Arlington, VA, and at the Office of the Federal Register, 800 North 
    Capitol Street, NW., Suite 700, Washington, DC. In addition, copies of 
    the document can be purchased from the American Society for Testing 
    Materials (ASTM), 1916 Race Street, Philadelphia, Pennsylvania 19103. 
    This incorporation by reference was approved by the Director of the 
    Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.
    * * * * *
        (d) * * *
        (1) Made of noncombustible material or coated on all accessible 
    surfaces with flame-retardant material having a flame- spread index of 
    25 or less, as tested under ASTM E162-87, ``Standard Test Method for 
    Surface Flammability of Materials Using a Radiant Heat Energy Source.'' 
    This publication is incorporated by reference and may be inspected at 
    any Coal Mine Health and Safety District and Subdistrict Office, or at 
    MSHA's Office of Standards, 4015 Wilson Boulevard, Arlington, VA, and 
    at the Office of the Federal Register, 800 North Capitol Street, NW., 
    Suite 700, Washington, DC. In addition, copies of the document can be 
    purchased from the American Society for Testing Materials (ASTM), 1916 
    Race Street, Philadelphia, Pennsylvania 19103. This incorporation by 
    reference was approved by the Director of the Federal Register in 
    accordance with 5 U.S.C. 552(a) and 1 CFR part 51.
    * * * * *
        (e) * * *
        (3) When timbers are used to create permanent stoppings in heaving 
    or caving areas, the stoppings shall be coated on all accessible 
    surfaces with a flame-retardant material having a flame-spread index of 
    25 or less, as tested under ASTM E162-87, ``Standard Test Method for 
    Surface Flammability of Materials Using a Radiant Heat Energy Source.'' 
    This publication is incorporated by reference and may be inspected at 
    any Coal Mine Health and Safety District and Subdistrict Office, or at 
    MSHA's Office of Standards, 4015 Wilson Boulevard, Arlington, VA, and 
    at the Office of the Federal Register, 800 North Capitol Street, NW., 
    Suite 700, Washington, DC. In addition, copies of the document can be 
    purchased from the American Society for Testing Materials (ASTM), 1916 
    Race Street, Philadelphia, Pennsylvania 19103. This incorporation by 
    reference was approved by the Director of the Federal Register in 
    accordance with 5 U.S.C. 552(a) and 1 CFR part 51.
    * * * * *
        (f) When sealants are applied to ventilation controls, the sealant 
    shall have a flame-spread index of 25 or less under ASTM E162-87, 
    ``Standard Test Method for Surface Flammability of Materials Using a 
    Radiant Heat Energy Source.'' This publication is incorporated by 
    reference and may be inspected at any Coal Mine Health and Safety 
    District and Subdistrict Office, or at MSHA's Office of Standards, 4015 
    Wilson Boulevard, Arlington, VA, and at the Office of the Federal 
    Register, 800 North Capitol Street, NW., Suite 700, Washington, DC. In 
    addition, copies of the document can be purchased from the American 
    Society for Testing Materials (ASTM), 1916 Race Street, Philadelphia, 
    Pennsylvania 19103. This incorporation by reference was approved by the 
    Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 
    1 CFR part 51.
    * * * * *
    
    
    Sec. 75.335  [Amended]
    
        4. In Sec. 75.335, paragraphs (a)(1)(iv) and (a)(2) are revised to 
    read as follows:
        (a)(1) * * *
        (iv) Coated on all accessible surfaces with flame-retardant 
    material that will minimize leakage and that has a flame-spread index 
    of 25 or less, as tested under ASTM E162-87, ``Standard Test Method for 
    Surface Flammability of Materials Using a Radiant Heat Energy Source.'' 
    This publication is incorporated by reference and may be inspected at 
    any Coal Mine Health and Safety District and Subdistrict Office, or at 
    MSHA's Office of Standards, 4015 Wilson Boulevard, Arlington, VA, and 
    at the Office of the Federal Register, 800 North Capitol Street, NW., 
    Suite 700, Washington, DC. In addition, copies of the document can be 
    purchased from the American Society for Testing Materials (ASTM), 1916 
    Race Street, Philadelphia, Pennsylvania 19103. This incorporation by 
    reference was approved by the Director of the Federal Register in 
    accordance with 5 U.S.C. 552(a) and 1 CFR part 51.
        (2) Alternative methods or materials may be used to create a seal 
    if they can withstand a static horizontal pressure of 20 pounds per 
    square inch provided the method of installation and the material used 
    is approved in the ventilation plan. If the alternative methods or 
    materials include the use of timbers, the timbers also shall be coated 
    on all accessible surfaces with flame-retardant material having a 
    flame-spread index of 25 or less, as tested under ASTM E162-87, 
    ``Standard Test Method for Surface Flammability of Materials Using a 
    Radiant Heat Energy Source.'' This publication is incorporated by 
    reference and may be inspected at any Coal Mine Health and Safety 
    District and Subdistrict Office, or at MSHA's Office of Standards, 4015 
    Wilson Boulevard, Arlington, VA, and at the Office of the Federal 
    Register, 800 North Capitol Street, NW., Suite 700, Washington, DC. In 
    addition, copies of the document can be purchased from the American 
    Society for Testing Materials (ASTM), 1916 Race Street, Philadelphia, 
    Pennsylvania 19103. This incorporation by reference was approved by the 
    Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 
    1 CFR part 51.
    * * * * *
    [FR Doc. 94-18302 Filed 7-27-94; 8:45 am]
    BILLING CODE 4510-43-P
    
    
    

Document Information

Effective Date:
7/28/1994
Published:
07/28/1994
Department:
Mine Safety and Health Administration
Entry Type:
Uncategorized Document
Action:
Final rule; technical amendments.
Document Number:
94-18302
Dates:
This regulation is effective July 28, 1994. The incorporation by reference of certain publications listed in the regulations is approved by the Director of the Federal Register as of July 28, 1994.
Pages:
0-0 (None pages)
Docket Numbers:
Federal Register: July 28, 1994
RINs:
1219-AA11: Underground Coal Mine Ventilation
RIN Links:
https://www.federalregister.gov/regulations/1219-AA11/underground-coal-mine-ventilation
CFR: (3)
1 CFR 75.333
1 CFR 75.335
30 CFR 75.301