94-22605. Energy Conservation Program for Consumer Products: Decision and Order Granting a Waiver From the Furnace Test Procedure to Evcon Industries, Inc.  

  • [Federal Register Volume 59, Number 176 (Tuesday, September 13, 1994)]
    [Unknown Section]
    [Page 0]
    From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
    [FR Doc No: 94-22605]
    
    
    [[Page Unknown]]
    
    [Federal Register: September 13, 1994]
    
    
    -----------------------------------------------------------------------
    
    DEPARTMENT OF ENERGY
    Office of Energy Efficiency and Renewable Energy
    [Case No. F-072]
    
     
    
    Energy Conservation Program for Consumer Products: Decision and 
    Order Granting a Waiver From the Furnace Test Procedure to Evcon 
    Industries, Inc.
    
    AGENCY: Office of Energy Efficiency and Renewable Energy, Department of 
    Energy.
    
    ACTION: Decision and Order.
    
    -----------------------------------------------------------------------
    
    SUMMARY: Notice is given of the Decision and Order (Case No. F-072) 
    granting a Waiver to Evcon Industries, Inc. (Evcon) from the existing 
    Department of Energy (DOE) test procedure for furnaces. The Department 
    is granting Evcon's Petition for Waiver regarding blower time delay in 
    calculation of Annual Fuel Utilization Efficiency (AFUE) for its AGU, 
    BGU, and BGD series gas furnaces.
    
    FOR FURTHER INFORMATION CONTACT:
    
    Cyrus H. Nasseri, U.S. Department of Energy, Office of Energy 
    Efficiency and Renewable Energy, Mail Station EE-431, Forrestal 
    Building, 1000 Independence Avenue, SW., Washington, DC 20585, (202) 
    586-9138.
    
    Eugene Margolis, Esq., U.S. Department of Energy, Office of General 
    Counsel, Mail Station GC-72, Forrestal Building, 1000 Independence 
    Avenue, SW., Washington, DC 20585, (202) 586-9507.
    
    SUPPLEMENTARY INFORMATION: In accordance with 10 CFR 430.27(g), notice 
    is hereby given of the issuance of the Decision and Order as set out 
    below. In the Decision and Order, Evcon has been granted a Waiver for 
    its AGU, BGU, and BGD series gas furnaces, permitting the company to 
    use an alternate test method in determining AFUE.
    
        Issued in Washington, DC, on September 7, 1994.
    Christine A. Ervin,
    Assistant Secretary, Energy Efficiency and Renewable Energy.
        In the Matter of: Evcon Industries, Inc. (Case No. F-072)
    
    Background
    
        The Energy Conservation Program for Consumer Products (other 
    than automobiles) was established pursuant to the Energy Policy and 
    Conservation Act (EPCA), Public Law 94-163, 89 Stat. 917, as amended 
    by the National Energy Conservation Policy Act (NECPA), Public Law 
    95-619, 92 Stat. 3266, the National Appliance Energy Conservation 
    Act of 1987 (NAECA), Public Law 100-12, the National Appliance 
    Energy Conservation Amendments of 1988 (NAECA 1988), Public Law 100-
    357, and the Energy Policy Act of 1992 (EPAct), Public Law 102-486, 
    106 Stat. 2776, which requires DOE to prescribe standardized test 
    procedures to measure the energy consumption of certain consumer 
    products, including furnaces. The intent of the test procedures is 
    to provide a comparable measure of energy consumption that will 
    assist consumers in making purchasing decisions. These test 
    procedures appear at 10 CFR Part 430, Subpart B.
        The Department amended the prescribed test procedures by adding 
    10 CFR 430.27 to create a waiver process. 45 FR 64108, September 26, 
    1980. Thereafter, DOE further amended its appliance test procedure 
    waiver process to allow the Assistant Secretary for Energy 
    Efficiency and Renewable Energy (Assistant Secretary) to grant an 
    Interim Waiver from test procedure requirements to manufacturers 
    that have petitioned DOE for a waiver of such prescribed test 
    procedures. 51 FR 42823, November 26, 1986.
        The waiver process allows the Assistant Secretary to waive 
    temporarily test procedures for a particular basic model when a 
    petitioner shows that the basic model contains one or more design 
    characteristics which prevent testing according to the prescribed 
    test procedures or when the prescribed test procedures may evaluate 
    the basic model in a manner so unrepresentative of its true energy 
    consumption as to provide materially inaccurate comparative data. 
    Waivers generally remain in effect until final test procedure 
    amendments become effective, resolving the problem that is the 
    subject of the waiver.
        The Interim Waiver provisions added by the 1986 amendment allow 
    the Assistant Secretary to grant an Interim Waiver when it is 
    determined that the applicant will experience economic hardship if 
    the Application for Interim Waiver is denied, if it appears likely 
    that the Petition for Waiver will be granted, and/or the Assistant 
    Secretary determines that it would be desirable for public policy 
    reasons to grant immediate relief pending a determination on the 
    Petition for Waiver. An Interim Waiver remains in effect for a 
    period of 180 days or until DOE issues its determination on the 
    Petition for Waiver, whichever is sooner, and may be extended for an 
    additional 180 days, if necessary.
        Evcon filed a ``Petition for Waiver,'' dated May 11, 1994, in 
    accordance with section 430.27 of 10 CFR Part 430. The Department 
    published in the Federal Register on July 14, 1994, Evcon's petition 
    and solicited comments, data and information respecting the 
    petition. 59 FR 35916. Evcon also filed an ``Application for Interim 
    Waiver'' under section 430.27(g) which DOE granted on July 9, 1994. 
    59 FR 35916, July 14, 1994.
        No comments were received concerning either the ``Petition for 
    Waiver'' or the ``Interim Waiver.'' The Department consulted with 
    The Federal Trade Commission (FTC) concerning the Evcon Petition. 
    The FTC did not have any objections to the issuance of the waiver to 
    Evcon.
    
    Assertions and Determinations
    
        Evcon's Petition seeks a waiver from the DOE test provisions 
    that require a 1.5-minute time delay between the ignition of the 
    burner and the starting of the circulating air blower. Evcon 
    requests the allowance to test using a 30-second blower time delay 
    when testing its AGU, BGU, and BGD series gas furnaces. Evcon states 
    that since the 30-second delay is indicative of how these models 
    actually operate and since such a delay results in a 1.0 to 2.0 
    percent improvement in overall energy efficiency, the petition 
    should be granted.
        Under specific circumstances, the DOE test procedure contains 
    exceptions which allow testing with blower delay times of less than 
    the prescribed 1.5 minute delay. Evcon indicates that it is unable 
    to take advantage of any of these exceptions for its AGU, BGU, and 
    BGD series gas furnaces.
        Since the blower controls incorporated on the Evcon furnaces are 
    designed to impose a 30-second blower delay in every instance of 
    start up, and since the current provisions do not specifically 
    address this type of control, DOE agrees that a waiver should be 
    granted to allow the 30-second blower time delay when testing the 
    Evcon AGU, BGU, and BGD series gas furnaces. Accordingly, with 
    regard to testing the AGU, BGU, and BGD series gas furnaces, today's 
    Decision and Order exempts Evcon from the existing provisions 
    regarding blower controls and allows testing with the 30-second 
    delay.
    
    It is, therefore, ordered that:
    
        (1) The ``Petition for Waiver'' filed by Evcon Industries, Inc. 
    (Case No. F-072) is hereby granted as set forth in paragraph (2) 
    below, subject to the provisions of paragraphs (3), (4), and (5).
        (2) Notwithstanding any contrary provisions of Appendix N of 10 
    CFR Part 430, Subpart B, Evcon Industries, Inc., shall be permitted 
    to test its AGU, BGU, and BGD series gas furnaces on the basis of 
    the test procedure specified in 10 CFR Part 430, with modifications 
    set forth below:
        (i) Section 3.0 of Appendix N is deleted and replaced with the 
    following paragraph:
        3.0 Test Procedure. Testing and measurements shall be as 
    specified in section 9 in ANSI/ASHRAE Standard 103-82 with the 
    exception of sections 9.2.2, 9.3.1, and 9.3.2, and the inclusion of 
    the following additional procedures:
        (ii) Add a new paragraph 3.10 to Appendix N as follows:
        3.10 Gas- and Oil-Fueled Central Furnaces. The following 
    paragraph is in lieu of the requirement specified in section 9.3.1 
    of ANSI/ASHRAE Standard 103-82. After equilibrium conditions are 
    achieved following the cool-down test and the required measurements 
    performed, turn on the furnace and measure the flue gas temperature, 
    using the thermocouple grid described above, at 0.5 and 2.5 minutes 
    after the main burner(s) comes on. After the burner start-up, delay 
    the blower start-up by 1.5 minutes (t-), unless: (1) the furnace 
    employs a single motor to drive the power burner and the indoor air 
    circulating blower, in which case the burner and blower shall be 
    started together; or (2) the furnace is designed to operate using an 
    unvarying delay time that is other than 1.5 minutes, in which case 
    the fan control shall be permitted to start the blower; or (3) the 
    delay time results in the activation of a temperature safety device 
    which shuts off the burner, in which case the fan control shall be 
    permitted to start the blower. In the latter case, if the fan 
    control is adjustable, set it to start the blower at the highest 
    temperature. If the fan control is permitted to start the blower, 
    measure time delay, (t-), using a stopwatch. Record the measured 
    temperatures. During the heat-up test for oil-fueled furnaces, 
    maintain the draft in the flue pipe within 0.01 inch of 
    water column of the manufacturer's recommended on-period draft.
        (iii) With the exception of the modifications set forth above, 
    Evcon Industries, Inc. shall comply in all respects with the test 
    procedures specified in Appendix N of 10 CFR Part 430, Subpart B.
        (3) The Waiver shall remain in effect from the date of issuance 
    of this Order until DOE prescribes final test procedures appropriate 
    to the AGU, BGU, and BGD series gas furnaces manufactured by Evcon 
    Industries, Inc.
        (4) This Waiver is based upon the presumed validity of 
    statements, allegations, and documentary materials submitted by the 
    petitioner. This Waiver may be revoked or modified at any time upon 
    a determination that the factual basis underlying the petition is 
    incorrect.
        (5) Effective September 7, 1994, this Waiver supersedes the 
    Interim Waiver granted the Evcon Industries, Inc. on July 9, 1994. 
    59 FR 35916, July 14, 1994 (Case No. F-072).
    
        Issued In Washington, DC, on September 7, 1994.
    Christine A. Ervin,
    Assistant Secretary, Energy Efficiency and Renewable Energy.
    [FR Doc. 94-22605 Filed 9-12-94; 8:45 am]
    BILLING CODE 6450-01-P
    
    
    

Document Information

Published:
09/13/1994
Department:
Energy Efficiency and Renewable Energy Office
Entry Type:
Uncategorized Document
Action:
Decision and Order.
Document Number:
94-22605
Pages:
0-0 (1 pages)
Docket Numbers:
Federal Register: September 13, 1994, Case No. F-072