C5-16195. Guidelines Establishing Test Procedures for the Analysis of Pollutants; Analytical Methods for Biological Pollutants in Wastewater and Sewage Sludge; Proposed Rule  

  • Start Preamble Start Printed Page 52485 End Preamble Start Supplemental Information

    Correction

    In proposed rule document 05-16195 beginning on page 48256, in the issue of Tuesday, August 16, 2005, make the following corrections:

    [Corrected]

    1. On page 48264, in §136.3(a), in the table, under the heading Method1, in the eighth line, “MF12 16” should read “MF2 16”.

    2. On page 48267, in the same section, the table is corrected in part to read as follows:

    Table IG.—List of Approved Microbiological Methods for Ambient Water

    Parameter and unitsMethod 1EPAStandard methods 18th, 19th, 20th ed.4Standard methods on-line 4AOAC, ASTM, USGSOther
    *         *         *         *         *         *         *
    7. Enterococci, number per 100 mLMTF 6 8 multiple tube multiple tube/multiple well9230B9230B-93D6503-99 9  Entero- lert ® 12 22
    MF 2 5 6 7 8 two step,1106.1 239230C9230C-93D5259-92 9
    single step, or Plate count1600 24, p. 143 3
    Protozoa:
    8. CryptosporidiumFiltration/IMS/FA1622 25, 1623 26
    9. GiardiaFiltration/IMS/FA1623 26
    End Supplemental Information

    [FR Doc. C5-16195 Filed 9-1-05; 8:45 am]

    BILLING CODE 1505-01-D