DEPARTMENT OF COMMERCE
The University of Texas Health Science Center, et al.; Notice of
Consolidated Decision on Applications for Duty-Free Entry of Scientific
Instruments
This is a decision consolidated pursuant to Section 6(c) of the
Educational, Scientific, and Cultural Materials Importation Act of 1966
(Pub. L. 89-651, 80 Stat. 897; 15 CFR part 301). Related records can be
viewed between 8:30 A.M. and 5:00 P.M. in Room 4211, U.S. Department of
Commerce, 14th and Constitution Avenue, N.W., Washington, D.C.
Comments: None received. Decision: Approved. No instrument of
equivalent scientific value to the foreign instruments described below,
for such purposes as each is intended to be used, is being manufactured
in the United States.
Docket Number: 94-052. Applicant: The University of Texas Health
Science Center, Houston, TX 77030. Instrument: Manipulators, Ball
Joints and Magnetic Stands. Manufacturer: Narishige, Japan. Intended
Use: See notice at 59 FR 29417, June 7, 1994. Reasons: The foreign
instrument provides: (1) right or left handed operation, (2) a meta
barrier, (3) suction, (4) thermister and microscope in a crowded setup
and (5) small size and light weight. Advice Received From: National
Institutes of Health, July 18, 1994.
Docket Number: 94-053. Applicant: University of Alabama at
Birmingham, Birmingham, AL 35249. Instrument: Mass Spectrometer, Model
Optima. Manufacturer: Fisons Instruments, United Kingdom. Intended Use:
See notice at 59 FR 29417, June 7, 1994. Reasons: The foreign
instrument provides a sensitivity of 1 mass 44 ion per 1100 molecules
of C02 and cold finger internal precision of 0.02 per mil for 1
bar l samples of C02. Advice Received From: National
Institutes of Health, July 18, 1994.
Docket Number: 94-059. Applicant: Louisiana Tech University,
Ruston, LA 71272. Instrument: Deep X-ray Lithography Scanner.
Manufacturer: Jenotik, GmbH, Germany. Intended Use: See notice at 59 FR
29417, June 7, 1994. Reasons: The foreign instrument provides an
enclosed system that can be evacuated to 0.1 mbar and backfilled with
helium to minimize exposure of polymer chains to oxygen. Advice
Received From: A university research department, July 26, 1994.
Docket Number: 94-060. Applicant: Massachusetts Institute of
Technology, Cambridge, MA 02139. Instrument: Triaxial Deformation
Apparatus for testing rocks at high temperature and pressure.
Manufacturer: Paterson Instruments Pty, Ltd., Australia. Intended Use:
See notice at 59 FR 29417, June 7, 1994. Reasons: The foreign
instrument provides: (1) temperatures to 1400 deg.C, (2) confining
pressures to 700 MPa, (3) maximum axial load to 100 kN and (4)
measurement of permeability and fluid transport during triaxial
testing. Advice Received From: Los Alamos National Laboratory, August
3, 1994.
Docket Number: 94-062. Applicant: Rutgers University, New
Brunswick, NJ 08903-0231. Instrument: Fluorometer, Model Aquatracka.
Manufacturer: Chelsea Instruments, Ltd., United Kingdom. Intended Use:
See notice at 59 FR 29417, June 7, 1994. Reasons: The foreign
instrument provides: (1) a single log scale covering four decades, (2)
changeable filters and (3) interface with a CTD data logger. Advice
Received From: National Institutes of Health, July 18, 1994.
Docket Number: 94-063. Applicant: Regents of the University of
California, Berkeley, Berkeley, CA 94720. Instrument: Segmented Thermal
Manikin. Manufacturer: Thermal Insulation Laboratory, Denmark. Intended
Use: See notice at 59 FR 29417, June 7, 1994. Reasons: The foreign
instrument provides: (1) a manikin with 16 body segments, (2) outside
computer controlled heating and skin temperature elements and (4) a
breathing function simulator. Advice Received From: National Institutes
of Health, July 18, 1994.
Docket Number: 94-077. Applicant: The Ohio State University,
Columbus, OH 43235. Instrument: High Power, High Pressure Arc Discharge
Plasma Source System. Manufacturer: Institute of Problems of
Electrophysics, CIS. Intended Use: See notice at 59 FR 34412, July 5,
1994. Reasons: The foreign instrument provides high pressure plasma
flow with high power (to 100 GW) and impulse pressure (to 1000 MPa) for
efficient acceleration of projectiles to high speeds (>4000 m/s).
Advice Received From: The Army Research Laboratory, Aberdeen, August 4,
1994.
The National Institutes of Health, a university research
department, Los Alamos National Laboratory and The Army Research
Laboratory, advise that (1) the capabilities of each of the foreign
instruments described above are pertinent to each applicant's intended
purpose and (2) they know of no domestic instrument or apparatus of
equivalent scientific value for the intended use of each instrument.
We know of no other instrument or apparatus being manufactured in
the United States which is of equivalent scientific value to any of the
foreign instruments.
Pamela Woods,
Acting Director, Statutory Import Programs Staff.