04-12761. Mechanical Power-Transmission Apparatus; Mechanical Power Presses; Telecommunications; Hydrogen
-
Start Preamble
AGENCY:
Occupational Safety and Health Administration (OSHA), Department of Labor.
ACTION:
Final rule; technical amendments.
SUMMARY:
This final rule corrects errors in four OSHA standards. The first correction deletes two references to a nonexisting table in the Mechanical Power-Transmission Apparatus Standard. The second is a correction of typographical errors in the Mechanical Power Presses Standard. The third correction is to a cross-reference in the Telecommunications Standard. The fourth correction is to a reference to a table contained in the Hazardous Materials Standard for Hydrogen.
DATES:
This final rule becomes effective on June 8, 2004.
Start Further InfoFOR FURTHER INFORMATION CONTACT:
For general information and press inquiries, contact George Shaw, Acting Director, Office of Communications, Room N3637, OSHA, U.S. Department of Labor, 200 Constitution Avenue, NW., Washington, DC 20210; telephone: (202) 693-1999 or fax: (202) 693-1635. For technical information, contact Kenneth Stevanus, Office of Engineering Safety, Room N3609, OSHA, U.S. Department of Labor, 200 Constitution Avenue, NW., Washington, DC 20210; telephone: (202) 693-2260.
End Further Info End Preamble Start Supplemental InformationSUPPLEMENTARY INFORMATION:
I. Mechanical Power-Transmission Apparatus
OSHA standards 29 CFR 1910.219 and 29 CFR 1926.307 contain requirements for the construction of guards for all types of mechanical power-transmission apparatus. On November 24, 1978, OSHA revoked certain safety and health standards, including Tables O-12 and O-13 in 29 CFR 1910.219 (43 FR 49726, 49741). These tables contained specifications for materials used in guarding mechanical power-transmission apparatus. They were revoked because they were considered overly detailed and too restrictive of the kinds of materials used for guards (43 FR 49740). Further, all references to these two tables were also to be removed. However, OSHA neglected to remove two references to Table O-12.
The first reference to Table O-12 that still appears is found in paragraph (e)(1)(i) of 29 CFR 1910.219 and paragraph (e)(1)(i) of 29 CFR 1926.307, both of which read as follows:
Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height (see Table O-12), except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section. [Emphasis added.]
The second reference to Table O-12 is found in paragraph (o)(5)(ii) of 29 CFR 1910.219 and paragraph (o)(5)(ii) of 29 CFR 1926.307, both of which read as follows:
Posts shall be not more than eight (8) feet apart; they are to be permanent and substantial, smooth, and free from protruding nails, bolts, and splinters. If made of pipe, the post shall be one and one-fourth (11/4) inches inside diameter, or larger. If made of metal shapes or bars, their section shall be equal in strength to that of one and one-half (11/2) by one and one-half (11/2) by three-sixteenths (3/16) inch angle iron. If made of wood, the posts shall be two by four (2 × 4) inches or larger. The upper rail shall be two by four (2 × 4) inches, or two one by four (1 × 4) strips, one at the top and one at the side of posts. The midrail may be one by four (1 × 4) inches or more. Where panels are fitted with expanded metal or wire mesh as noted in Table O-12, the middle rails may be omitted. Where guard is exposed to contact with moving equipment, additional strength may be necessary. [Emphasis added.]
OSHA is removing the text referring to Table O-12 from all four of these paragraphs.
II. Mechanical Power Presses
On December 3, 1974, OSHA published in the Federal Register (39 FR 41841) a final rule on Mechanical Power Presses based on a petition to revoke 29 CFR 1910.217(d)(1) and (d)(2). As part of the final rule, a new paragraph (c)(5) was added, reading, in part, as follows:
Where the operator feeds or removes parts by placing one or both hands in the point of operation, and a two hand control, presence sensing device of Type B gate or movable barrier (on a part revolution clutch) is used for safeguarding:
The paragraph as printed contains typographical errors that change the meaning of the paragraph and imply that a Type-B gate is a presence-sensing device. This is not the case. A Type-B gate is considered a safety device when used with a failsafe control system and a brake monitor. Start Printed Page 31881
In the preamble to the December 3, 1974, Federal Register (39 FR 41843), OSHA stated:
In addition, presence sensing devices or two hand controls may be used on part revolution clutch presses. Where either of these devices, or a Type B gate, are used [sic], the employer must also use a failsafe control system and a brake monitor in order to qualify the device as a safety device.
Several paragraphs later, the Agency noted that commenters pointed out that:
[Paragraph] (b)(13) should also apply to the Type B gate or movable barrier device, because the effectiveness of this device also depends upon the performance of the brake (TR 423).
OSHA agreed with this (39 FR 41843) and stated:
Therefore, the final standard requires employers to comply with paragraph (b)(13) when using a Type B gate or movable barrier device, two-hand control, or a presence sensing device.
In this notice, OSHA is correcting the typographical error in 1910.217(c)(5) by adding a comma after the word “device” and deleting the word “of” before the word “Type.” The introductory text to paragraph (c)(5) will then read:
Where the operator feeds or removes parts by placing one or both hands in the point of operation, and a two hand control, presence sensing device, Type B gate or movable barrier (on a part revolution clutch) is used for safeguarding:
III. Telecommunications
On June 18, 1998, OSHA published a final rule in the Federal Register (63 FR 33450), removing and revising certain standards that were out of date, duplicative, unnecessary, or inconsistent. In that final rule, the Telecommunications Standard, 29 CFR 1910.268, was amended to: “Revise paragraph (f)(1), remove paragraphs (f)(2) through (f)(4) and (f)(7) through (f)(9) and re-designate paragraphs (f)(5) and (f)(6) as (f)(2) and (f)(3)” (63 FR 33467). However, redesignated paragraph (f)(3) of 29 CFR 1910.268 (former paragraph (f)(6)) has continued to include a cross-reference to former paragraph (f)(5):
Gloves and blankets shall be marked to indicate compliance with the retest schedule, and shall be marked with the date the next test is due. Gloves found to be defective in the field or by the tests set forth in paragraph (f)(5) of this section shall be destroyed by cutting them open from the finger to the gauntlet.
The 1998 notice should have corrected this cross-reference to refer to redesignated paragraph (f)(2) instead of (f)(5). OSHA is now correcting this cross-reference accordingly.
IV. Hydrogen
OSHA standard 29 CFR 1910.103 contains requirements for the installation of gaseous hydrogen systems on consumer premises where the hydrogen supply to the consumer premises originates outside the consumer premises and is delivered by mobile equipment. On October 24, 1978, OSHA revised certain safety and health standards, including Table H-2 in 29 CFR 1910.103 (43 FR 49732). This table contained specifications for the minimum distances used to determine placement of hydrogen systems of indicated capacity located outdoors, in special buildings or in special rooms to any specified outdoor exposure. The table was amended by removing line 13, “public sidewalks * * *,” and line 14, “line of adjoining property * * *,” because they dealt with public safety and property protection and were not within OSHA's regulatory jurisdiction (43 FR 49732).
However, a reference to line 14 in Table H-2 (referenced as “Item” 14) found at 29 CFR 1910.103(b)(2)(ii)(c) was not removed at that time. This paragraph still contains a cross-reference to the nonexistent Item 14 and states that: “The distances in Table H-2 Items 1, 14, and 3 to 10 inclusive do not apply where protective structures such as adequate fire walls are located between the system and the exposure.”
OSHA is revising paragraph (c) to read: “The distances in Table H-2 Items 1 and 3 to 10 inclusive do not apply where protective structures such as adequate fire walls are located between the system and the exposure.” This change will remove the cross-reference to the nonexistent item 14, and clarify the requirements contained in this paragraph.
V. Exemption From Notice-and-Comment Procedures
In accordance with the rulemaking provisions of the Administrative Procedures Act (5 U.S.C. 553) and 29 CFR 1911.5, OSHA hereby finds good cause to publish these amendments without any further delay or public procedure. They do not change any existing rights or obligations and no stakeholder is likely to object to them. Therefore, the Agency finds that public notice-and-comment procedures are unnecessary within the meaning of 5 U.S.C. 553(b)(3)(b) and 29 CFR 1911.5.
Start List of SubjectsList of Subjects
29 CFR Part 1910
- Hazardous substances
- Hydrogen, and Occupational safety and health
29 CFR Part 1926
- Construction industry, and Occupational safety and health
Accordingly, pursuant to section 6 of the Occupational Safety and Health Act of 1970 (29 U.S.C. 655), Section 4 of the Administrative Procedure Act (5 U.S.C. 553) and Secretary of Labor's Order No. 5-2002 (67 FR 65008), OSHA is amending 29 CFR parts 1910 and 1926 as set forth below.
End Amendment Part Start SignatureSigned at Washington, DC this 28th day of May, 2004.
John L. Henshaw,
Assistant Secretary of Labor.
PART 1910—[AMENDED]
Subpart H—Hazardous Materials—[Amended]
End Part Start Amendment Part1. The authority citation for Subpart H of Part 1910 is revised to read as follows:
End Amendment PartSection 1910.119 also issued under section 304, Clean Air Act Amendments of 1990 (Pub. L. 101-549), reprinted at 29 U.S.C. 655 Note.
Section 1910.120 also issued under section 126, Superfund Amendments and Reauthorization Act of 1986 as amended (29 U.S.C. 655 Note), and 5 U.S.C. 553.
Start Amendment Part2. In § 1910.103, paragraph (b)(2)(ii)( c) introductory text is revised to read as follows:
End Amendment PartHydrogen.* * * * *(b) * * *
(2) * * *
(ii) * * *
(c) The distances in Table H-2 Items 1 and 3 to 10 inclusive do not apply where protective structures such as adequate fire walls are located between the system and the exposure.
* * * * *Subpart O—Machinery and Machine Guarding—[Amended]
Start Amendment Part3. The authority citation for Subpart O of Part 1910 is revised to read as follows:
End Amendment Part[Amended]4. In § 1910.217, the introductory text to paragraph (c)(5) is amended by adding a comma after the word “device” and removing the word “of” before the word “type.”
End Amendment Part[Amended]5. Paragraph (e)(1)(i) of § 1910.219 is amended by removing the text “(see Table O-12),” and paragraph (o)(5)(ii) is amended by removing the text “as noted in Table O-12.”
End Amendment PartSubpart R—Special Industries—[Amended]
Start Amendment Part6. The authority citation for Subpart R of Part 1910 is revised to read as follows:
End Amendment Part[Amended]7. Paragraph (f)(3) of § 1910.268 is amended by revising the text “paragraph (f)(5)” to read “paragraph (f)(2).”
End Amendment Part Start PartPART 1926—[AMENDED]
Subpart I—Tools-Hand and Power—[Amended]
End Part Start Amendment Part8. The authority citation for Subpart I of Part 1926 is revised to read as follows:
End Amendment Part[Amended]9. In § 1926.307, paragraph (e)(1)(i) is amended by removing the text “(see Table O-12),” and paragraph (o)(5)(ii) is amended by removing the text “as noted in Table O-12.”
End Amendment Part End Supplemental Information[FR Doc. 04-12761 Filed 6-7-04; 8:45 am]
BILLING CODE 4510-26-P
Document Information
- Effective Date:
- 6/8/2004
- Published:
- 06/08/2004
- Department:
- Occupational Safety and Health Administration
- Entry Type:
- Rule
- Action:
- Final rule; technical amendments.
- Document Number:
- 04-12761
- Dates:
- This final rule becomes effective on June 8, 2004.
- Pages:
- 31880-31882 (3 pages)
- Topics:
- Construction industry, Hazardous substances, Occupational safety and health
- PDF File:
- 04-12761.pdf
- CFR: (5)
- 29 CFR 1910.103
- 29 CFR 1910.217
- 29 CFR 1910.219
- 29 CFR 1910.268
- 29 CFR 1926.307