-
Start Preamble
CFR Correction
In Title 15 of the Code of Federal Regulations, Parts 300 to 799, revised as of January 1, 2011, on page 802, in Supplement No. 1 to Part 774, in Category 6, in ECCN 6A005, the following text is reinstated at the end of the entry:
6A005 “Lasers” (other than those described in 0B001.g.5 or .h.6), components and optical equipment, as follows (see List of Items Controlled).
* * * * *Start Printed Page 30539Items:
* * * * *d.5. “Chemical lasers”, as follows:
d.5.a. Hydrogen Fluoride (HF) “lasers”;
d.5.b. Deuterium Fluoride (DF) “lasers”;
d.5.c. “Transfer lasers”, as follows:
d.5.c.1. Oxygen Iodine (O2-I) “lasers”;
d.5.c.2. Deuterium Fluoride-Carbon dioxide (DF-CO2) “lasers”;
d.6. “Non-repetitive pulsed” Neodymium (Nd) glass “lasers”, having any of the following:
d.6.a. A “pulse duration” not exceeding 1 µs and an output energy exceeding 50 J per pulse; or
d.6.b. A “pulse duration” exceeding 1 µs and an output energy exceeding 100 J per pulse;
NOTE: “Non-repetitive pulsed” refers to “lasers” that produce either a single output pulse or that have a time interval between pulses exceeding one minute.
e. Components, as follows:
e.1. Mirrors cooled either by active cooling or by heat pipe cooling; Technical Note: Active cooling is a cooling technique for optical components using flowing fluids within the subsurface (nominally less than 1 mm below the optical surface) of the optical component to remove heat from the optic.
e.2. Optical mirrors or transmissive or partially transmissive optical or electro-optical components specially designed for use with controlled “lasers”;
f. Optical equipment, as follows:
N.B.: For shared aperture optical elements, capable of operating in “Super-High Power Laser” (“SHPL”) applications, see the U.S. Munitions List (22 CFR part 121).
f.1. Dynamic wavefront (phase) measuring equipment capable of mapping at least 50 positions on a beam wavefront having any the following:
f.1.a. Frame rates equal to or more than 100 Hz and phase discrimination of at least 5% of the beam's wavelength; or
f.1.b. Frame rates equal to or more than 1,000 Hz and phase discrimination of at least 20% of the beam's wavelength;
f.2. “Laser” diagnostic equipment capable of measuring “SHPL” system angular beam steering errors of equal to or less than 10 µrad;
f.3. Optical equipment and components specially designed for a phased-array “SHPL” system for coherent beam combination to an accuracy of lambda/10 at the designed wavelength, or 0.1 µm, whichever is the smaller;
f.4. Projection telescopes specially designed for use with “SHPL” systems.
End Preamble[FR Doc. 2011-13179 Filed 5-25-11; 8:45 am]
BILLING CODE 1505-01-D
Document Information
- Comments Received:
- 0 Comments
- Published:
- 05/26/2011
- Department:
- Industry and Security Bureau
- Entry Type:
- Rule
- Document Number:
- 2011-13179
- Pages:
- 30538-30539 (2 pages)
- PDF File:
- 2011-13179.pdf
- CFR: (1)
- 15 CFR 774