2015-23624. Energy Conservation Program: Energy Conservation Standards for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps; Correction  

  • Start Preamble

    AGENCY:

    Office of Energy Efficiency and Renewable Energy, Department of Energy.

    ACTION:

    Final rule; correction.

    SUMMARY:

    On July 21, 2015, the U.S. Department of Energy published a final rule amending energy conservation standards for packaged terminal air conditioners and packaged terminal heat pumps. 80 FR 43162. This correction addresses a table labeling error in that final rule.

    DATES:

    Effective Date: September 21, 2015.

    Start Further Info

    FOR FURTHER INFORMATION CONTACT:

    Mr. John Cymbalsky, U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Office, Mailstop EE-5B, 1000 Independence Avenue SW., Washington, DC 20585-0121. Telephone: (202) 586-0371. Email: pachaged_terminal_equipement@ee.doe.gov.

    Jennifer Tiedeman, U.S. Department of Energy, Office of the General Counsel, GC-33, 1000 Independence Avenue SW., Washington, DC 20585-0121. Telephone: (202) 287-6111. Email: Jennifer.Tiedeman@hq.doe.gov.

    End Further Info End Preamble Start Supplemental Information

    SUPPLEMENTARY INFORMATION:

    The U.S. Department of Energy (DOE) published a final rule in the Federal Register on July 21, 2015 (“the July 2015 final rule”) amending energy conservation standards for packaged terminal air conditioners and packaged terminal heat pumps 80 FR 43162. This correction addresses a table labeling error in the regulatory text of the July 2015 final rule. The instruction amending 10 CFR 431.97 in that rule revised paragraph (c) and incorrectly referenced the tables within as tables 4 and 5. This instruction put the table numbers in conflict with a previous amendment of July 17, 2015, which incorporated table 4 into paragraph (b). 80 FR 42614. The substance of the tables is correct, however, and is to be retained. In order to remedy this error, DOE is issuing a final rule correction to eliminate any table number conflicts, as set forth below.Start Printed Page 56895

    This rule corrects in 10 CFR 431.97, paragraph (c) all references to Table 4 and Table 5 to read as Table 5 and Table 6, respectively. The effective date for this rule is September 21, 2015.

    Correction

    In FR Doc. 2015-16897, published in the issue of Tuesday, July 21, 2015 (80 FR 43162), on page 43212, in the second column, amendatory instruction 2 is corrected to read as follows:

    Start Amendment Part

    2. Amend § 431.97 by revising paragraph (c) to read as follows:

    End Amendment Part
    Energy efficiency standards and their compliance dates.
    * * * * *

    (c) Each non-standard size packaged terminal air conditioner (PTAC) and packaged terminal heat pump (PTHP) manufactured on or after October 7, 2010 must meet the applicable minimum energy efficiency standard level(s) set forth in Table 5 of this section. Each standard size PTAC manufactured on or after October 8, 2012, and before January 1, 2017 must meet the applicable minimum energy efficiency standard level(s) set forth in Table 5 of this section. Each standard size PTHP manufactured on or after October 8, 2012 must meet the applicable minimum energy efficiency standard level(s) set forth in Table 5 of this section. Each standard size PTAC manufactured on or after January 1, 2017 must meet the applicable minimum energy efficiency standard level(s) set forth in Table 6 of this section.

    Table 5 to § 431.97—Minimum Efficiency Standards for PTAC and PTHP

    Equipment typeCategoryCooling capacityEfficiency levelCompliance date: products manufactured on and after . . .
    PTACStandard Size<7,000 Btu/hEER = 11.7October 8, 2012.2
    ≥7,000 Btu/h and ≤15,000 Btu/hEER = 13.8−(0.3 × Cap 1)October 8, 2012.2
    >15,000 Btu/hEER = 9.3October 8, 2012.2
    Non-Standard Size<7,000 Btu/hEER = 9.4October 7, 2010.
    ≥7,000 Btu/h and ≤15,000 Btu/hEER = 10.9−(0.213 × Cap 1)October 7, 2010.
    >15,000 Btu/hEER = 7.7October 7, 2010.
    PTHPStandard Size<7,000 Btu/hEER = 11.9 COP = 3.3October 8, 2012.
    ≥7,000 Btu/h and ≤15,000 Btu/hEER = 14.0−(0.3 × Cap 1) COP = 3.7−(0.052 × Cap 1)October 8, 2012.
    >15,000 Btu/hEER = 9.5 COP = 2.9October 8, 2012.
    Non-Standard Size<7,000 Btu/hEER = 9.3 COP = 2.7October 7, 2010.
    ≥7,000 Btu/h and ≤15,000 Btu/hEER = 10.8−(0.213 × Cap 1) COP = 2.9−(0.026 × Cap 1)October 7, 2010.
    >15,000 Btu/hEER = 7.6 COP = 2.5October 7, 2010.
    1 “Cap” means cooling capacity in thousand Btu/h at 95 °F outdoor dry-bulb temperature.
    2 And manufactured before January 1, 2017. See Table 6 of this section for updated efficiency standards that apply to this category of equipment manufactured on and after January 1, 2017.

    Table 6 to § 431.97—Updated Minimum Efficiency Standards for PTAC

    Equipment typeCategoryCooling capacityEfficiency levelCompliance date: products manufactured on and after . . .
    PTACStandard Size<7,000 Btu/hEER = 11.9January 1, 2017.
    ≥7,000 Btu/h and ≤15,000 Btu/hEER = 14.0−(0.3 × Cap 1)January 1, 2017.
    >15,000 Btu/hEER = 9.5January 1, 2017.
    1 “Cap” means cooling capacity in thousand Btu/h at 95 °F outdoor dry-bulb temperature.
    * * * * *
    Start Signature

    Issued in Washington, DC, on September 16, 2015.

    Kathleen B. Hogan,

    Deputy Assistant Secretary for Energy Efficiency, Energy Efficiency and Renewable Energy.

    End Signature End Supplemental Information

    [FR Doc. 2015-23624 Filed 9-18-15; 8:45 am]

    BILLING CODE 6450-01-P

Document Information

Effective Date:
9/21/2015
Published:
09/21/2015
Department:
Energy Department
Entry Type:
Rule
Action:
Final rule; correction.
Document Number:
2015-23624
Pages:
56894-56895 (2 pages)
Docket Numbers:
Docket Number EERE-2012-BT-STD-0029
RINs:
1904-AC82: Standards for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps
RIN Links:
https://www.federalregister.gov/regulations/1904-AC82/standards-for-packaged-terminal-air-conditioners-and-packaged-terminal-heat-pumps
PDF File:
2015-23624.pdf
Supporting Documents:
» Final Rule Spreadsheet: National Impact Analysis (NIA)
» Final Rule Spreadsheet: Life-Cycle Cost (LCC)
» 2015 Final Rule Spreadsheet: Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps, Government Regulatory Impact Model (GRIM)
» 201506 Final Rule: Technical Support Document: Energy Efficiency Program for Commercial and Industrial Equipment: Packaged Terminal Air Conditioners and Heat Pumps
» 2014-10-29 Record of Attendance: Webinar Attendees: The Package Terminal Air Conditioning and Package Terminal Heat Pumps Standards Meeting
» 2014-10-29 Record of Attendance: In-Person Attendees: The Package Terminal Air Conditioning and Package Terminal Heat Pumps Standards Meeting
» 2014-10-29 Public Meeting Transcript: Notice of Proposed Rulemaking (NOPR) for Packaged Terminal Air Conditioners (PTACs) and Packaged Terminal Heat Pumps (PTHPs)
» 2014-10-29 Presentation Slide Deck: Clarifications to PTAC ECS NOPR Public Meeting Presentation
» Updated Test Unit Tables 5.6.1 and 5.6.2 for TSD Chapter 5. Engineering Analysis
» 2014-10-29 Webinar Report