Comment from Larry Foley, Foley Engineering, LLC

Document ID: BSEE-2012-0002-0011
Document Type: Public Submission
Agency: Bureau Of Safety And Environmental Enforcement
Received Date: November 30 2010, at 12:00 AM Eastern Standard Time
Date Posted: November 30 2010, at 12:00 AM Eastern Standard Time
Comment Start Date: August 21 2012, at 12:00 AM Eastern Standard Time
Comment Due Date: 
Tracking Number: 810e730c
View Document:  View as format xml

View Comment

It appears that some of the requirements of NTL 2010-N05 which applied to workover BOPs have been omitted in the revision to 30 CFR 250.5XX and 250.6XX. Specifically, verification that the Blind/Shear is capable of shearing all pipe in the well at MASP has been omitted for workover and coiled tubing operations. Verification of this capability is as important in workover as it is in drilling, for both surface BOPs and subsurface BOPs. API RP 16ST, "Coiled Tubing Well Control Equipment Systems", Section 12, "Well Control Equipment Testing" should be referenced by 30 CFR 250.6XX in addition to the reference to API RP 53.