comments: re: docket id # epa hq oppt 2006 0044. we currently market a test kit (Lead Inspector Lead Test Kits) that may meet the specifications noted in docket id # epa hq oppt 2006 0044. our kits have shown to be effective in determining lead paint levels of 0.50% dry weight (or less). also: 1. false negative rate of less that 5% for paint below the regulated level (in-house lab reports) 2. false positive rate of less than 10% for paint below the regulated level (in-house lab reports) 3. cost is between $0.50 to $1.62 per test 4. results in 1-2 minutes - confirmation strips included to confirm is test working properly 5. can be used by all types of professionals or laymen. minimal training required. 6. can be used on any paint coating applied to wood, metal, plaster, drywall, brick, concrete etc.) with minimal interferences. regards, dmr. david lachance b.sc. president, abotex enterprises limited p.o. box 610421 port huron, mi 48061-0421 http://www.leadinspector.com 1-800-268-5323 1-519-238-8776 (direct line)

Related Comments

    View All
Total: 7
Comment submitted by B. Sachau
Public Submission    Posted: 03/16/2006     ID: EPA-HQ-OPPT-2006-0044-0002

Apr 17,2006 11:59 PM ET
Comment submitted by Mary T. Giguere, Manager, North Carolina Department of Health and Human Services, Health Hazards Control Unit
Public Submission    Posted: 04/14/2006     ID: EPA-HQ-OPPT-2006-0044-0006

Apr 17,2006 11:59 PM ET
Comment submitted by William F. Gutknecht, Research Triangle Institute (RTI International)
Public Submission    Posted: 04/20/2006     ID: EPA-HQ-OPPT-2006-0044-0007

Apr 17,2006 11:59 PM ET
Comment submitted by Marcia J. Stone, President and Chief Technical Officer, Hybrivet Systems, Inc.
Public Submission    Posted: 05/04/2006     ID: EPA-HQ-OPPT-2006-0044-0010

Apr 17,2006 11:59 PM ET
Comment submitted by David Lachance, President, Abotex Enterprises Limited
Public Submission    Posted: 04/14/2006     ID: EPA-HQ-OPPT-2006-0044-0005

Apr 17,2006 11:59 PM ET