Comment (1) of Randal Cords on FR Doc # 2012-14872

Document ID: NRC-2012-0133-0002
Document Type: Public Submission
Agency: Nuclear Regulatory Commission
Received Date: July 20 2012, at 12:00 AM Eastern Daylight Time
Date Posted: August 10 2012, at 12:00 AM Eastern Standard Time
Comment Start Date: June 19 2012, at 12:00 AM Eastern Standard Time
Comment Due Date: July 20 2012, at 11:59 PM Eastern Standard Time
Tracking Number: 810a84ba
View Document:  View as format xml

View Comment

Mirion Technologies (GDS) Inc. is a NVLAP Accredited Dosimetry provider. We provide NRC Form 5 equivalent reports to many of our clients, as well as data in REIRS format. We do provide for automatic calculation of EDE for conditions applicable to “Using Dosimeter(s) While Wearing an Apron during Medical X-Ray Procedures”. Currently when EDE calculations for external sources are performed for individuals, we include the EDE in the comments section of the form 5 report. We do believe that the form 5 needs to be changed to properly document the EDEX. But there is a general practice of performing EDE calculation without assurance that the monitoring is performed correctly. The licensee is responsible for this assurance, not the Dosimetry provider. We have strict requirements for two badge EDE calculations that both the dosimeters must be received for processing together, and that the Collar badge would be worn on the collar. When the two badges are not returned together, it is assumed that the badges were not properly used for monitoring. If the badges are returned separately or the under the shield badge reads highest, we rely on our client to perform an investigation and assign an appropriate dose. We are concerned that the instruction should provide appropriately strict guidance for what values are included in the EDEX for the year. Any monitoring period where the EDE is not calculated, the collar DDE should be used in the accumulation of EDEX. Current guidance is that the EDE need not be calculated until the individual exceeds 25% of the Annual Limit. If the shielding is provided the effective dose is reduced, the EDEX should be calculated and recorded in addition to the DDE. The calculation should be done and reported irrelevant to the % of limit. Understanding that the EDEX is not relevant if the Limit is not exceeded.

Related Comments

   
Total: 4
Comment (1) of Randal Cords on FR Doc # 2012-14872
Public Submission    Posted: 08/10/2012     ID: NRC-2012-0133-0002

Jul 20,2012 11:59 PM ET
Comment (2) of Susan Reese on FR Doc # 2012-14872
Public Submission    Posted: 08/10/2012     ID: NRC-2012-0133-0003

Jul 20,2012 11:59 PM ET
Comment (3) of an anonymous individual on FR Doc # 2012-14872
Public Submission    Posted: 08/10/2012     ID: NRC-2012-0133-0004

Jul 20,2012 11:59 PM ET
Comment (5) of Ellen P. Anderson on NRC Form 5
Public Submission    Posted: 08/10/2012     ID: NRC-2012-0133-0005

Jul 20,2012 11:59 PM ET