§ 86.129-94 - Road load power, test weight, inertia weight class determination, and fuel temperature profile.
-
§ 86.129-94 Road load power, test weight, inertia weight class determination, and fuel temperature profile.
Section 86.129-94 includes text that specifies requirements that differ from § 86.129-80. Where a paragraph in § 86.129-80 is identical and applicable to § 86.129-94, this may be indicated by specifying the corresponding paragraph and the statement “[Reserved]. For guidance see § 86.129-80.” Where a corresponding paragraph of § 86.129-80 is not applicable, this is indicated by the statement “[Reserved].”
(a) Flywheels, electrical, or other means of simulating test weight as shown in the following table shall be used. If the equivalent test weight specified is not available on the dynamometer being used, the next higher equivalent test weight (not to exceed 250 pounds) available shall be used:
Road load power at 50 mi/hour - light duty trucks1 2 3 Test weight
basis4 5Test equivalent test weight
(pounds)Inertia weight class
(pounds)Up to 1062 1,000 1,000 1063 to 1187 1,125 1,000 1188 to 1312 1,250 1,250 1313 to 1437 1,375 1,250 1438 to 1562 1,500 1,500 1563 to 1687 1,625 1,500 1688 to 1812 1,750 1,750 1813 to 1937 1,875 1,750 1938 to 2062 2,000 2,000 2063 to 2187 2,125 2,000 2188 to 2312 2,250 2,250 2313 to 2437 2,375 2,250 2438 to 2562 2,500 2,500 2563 to 2687 2,625 2,500 2688 to 2812 2,750 2,750 2813 to 2937 2,875 2,750 2938 to 3062 3,000 3,000 3063 to 3187 3,125 3,000 3188 to 3312 3,250 3,000 3313 to 3437 3,375 3,500 3438 to 3562 3,500 3,500 3563 to 3687 3,625 3,500 3688 to 3812 3,750 3,500 3813 to 3937 3,875 4,000 3938 to 4125 4,000 4,000 4126 to 4375 4,250 4,000 4376 to 4625 4,500 4,500 4626 to 4875 4,750 4,500 4876 to 5125 5,000 5,000 5126 to 5375 5,250 5,000 5376 to 5750 5,500 5,500 5751 to 6250 6,000 6,000 6251 to 6750 6,500 6,500 6751 to 7250 7,000 7,000 7251 to 7750 7,500 7,500 7751 to 8250 8,000 8,000 8251 to 8750 8,500 8,500 8751 to 9250 9,000 9,000 9251 to 9750 9,500 9,500 9751 to 10250 10,000 10,000 10251 to 10750 10,500 10,500 10751 to 11250 11,000 11,000 11251 to 11750 11,500 11,500 11751 to 12250 12,000 12,000 12251 to 12750 12,500 12,500 12751 to 13250 13,000 13,000 13251 to 13750 13,500 13,500 13751 to 14000 14,000 14,000 (b)-(c) [Reserved]. For guidance see § 86.129-80.
(d) Fuel temperature profile -
(1) General requirements.
(i) To be tested for running losses, as specified in § 86.134, a vehicle must have a fuel temperature profile. The following procedure is used to generate the fuel temperature profile, which serves as a target for controlling fuel temperatures during the running loss test. This profile represents the fuel temperature change that occurs during on-road driving. If a vehicle has more than one fuel tank, a profile shall be established for each tank. Manufacturers may also simultaneously generate a profile for vapor temperatures.
(ii) If a manufacturer uses a vehicle model to develop a profile to represent multiple models, the vehicle model selected must have the greatest expected fuel temperature increase during driving of all those models it represents. Also, manufacturers must select test vehicles with any available vehicle options that increase fuel temperatures during driving (for example, any feature that limits underbody airflow).
(iii) Manufacturers may conduct testing to develop fuel temperature profiles in a laboratory setting, subject to approval by the Administrator. The laboratory facility should simulate outdoor testing to reproduce fuel and vapor temperature behavior over the specified driving schedule. The design of the laboratory facility should include consideration of any parameters that may affect fuel temperatures, such as solar loading, pavement heat, and relative wind velocities around and underneath the test vehicle. Indoor testing to develop the fuel temperature profiles must be conducted with little or no vehicle-specific adjustment of laboratory parameters. Manufacturers would need to maintain an ongoing demonstration of correlation between laboratory and outdoor measurement of fuel temperatures. Specifically, fuel temperatures and pressures from indoor driving should be at least as high as measured when driving outdoors according to the procedures described in this section.
(iv) Small-volume manufacturers, as defined in § 86.094-14(b)(1), may use an alternate method for generating fuel temperature profiles, subject to the approval of the Administrator.
(v) The Administrator may conduct testing to establish any vehicle's temperature profiles or to verify compliance with fuel tank pressure requirements.
(2) Vehicle instrumentation.
(i) The vehicle must be equipped with temperature sensors and pressure transducers, as described in § 86.107-96 (e) and (f), and a driver's aid, which shall be configured to provide the test driver with the desired vehicle speed vs. time trace and the actual vehicle speed.
(ii) A computer, data logger, or strip chart data recorder shall record the following parameters at a minimum during the test run:
(A) Desired speed;
(B) Actual speed;
(C) Instantaneous average liquid fuel temperature (Tliq); and
(D) Vapor space pressure (the Administrator may omit measurement of fuel tank pressure).
(iii) The data recording system described in paragraph (d)(2)(ii) of this section shall be capable of resolving time to ±1 s, capable of resolving temperature to ±2 °F, capable of resolving pressure to ±1.0 inch of water, and capable of resolving speed to ±1 mph. The temperature and pressure signals shall be recorded at intervals of up to 1 minute; speed signals shall be recorded at intervals of up to 1 second.
(3) Ambient conditions. The procedure shall be run under the following ambient conditions. Conditions should be representative of sunny summer days.
(i) Starting ambient temperature (Tamb, o) shall be at least 95 °F, steady or increasing (no more than 2 °F drop) during the procedure. Ambient temperature shall be measured and recorded in regular intervals of at least once every 5 minutes. Measure ambient temperature with the following requirements (based on Federal Standard for Siting Meteorological Sensors at Airports, FCM-S4-1987). The sensors shall be mounted 5 ±1 feet (1.5 ±0.3 meters) above ground level. The sensors shall be protected from radiation from the sun, sky, earth, and any other surrounding objects, but at the same time be adequately ventilated. The sensors shall be installed in such a position as to ensure that measurements are representative of the free air circulation in the locality and not influenced by artificial conditions such as large buildings, cooling towers, and expanses of concrete and tarmac. Keep any grass and vegetation within 100 feet (30 meters) of the sensor clipped to a height of about 10 inches (25 centimeters) or less.
(ii) Wind conditions shall be calm to light with maximum wind speed of 15 mph. In the case of temporary gusting, wind speeds between 15 and 25 mph may occur for up to 5 percent of the total driving time without invalidating the data collection. Wind speed shall be measured and recorded in regular intervals of at least once per minute. Measure wind speed with the following requirements (based on Federal Standard for Siting Meteorological Sensors at Airports, FCM-S4-1987). The site should be relatively level, but small gradual slopes are acceptable. The sensor shall be mounted 30 to 33 feet (9 to 10 meters) above the average ground height within a radius of 500 feet (150 meters). The sensor height shall not exceed 33 feet, except as necessary to be at least 15 feet (5 meters) above the height of any obstruction (e.g. vegetation, buildings, etc.) within a 500 foot (150 meter) radius. An object is considered to be an obstruction if the included lateral angle from the sensor to the ends of the object is 10 degrees or more.
(iii) Road surface temperature shall be at least 125 °F throughout the driving period. Pavement temperature shall be measured and recorded in regular intervals of at least once per minute. The track temperature may be measured with an embedded sensor, a portable temperature probe, or an infrared pyrometer that can provide an accuracy of ±2 °F. Temperatures must be measured on a surface representative of the surface where the vehicle is driven.
(iv) Conditions shall be sunny or mostly sunny with a maximum cloud cover of 25 percent.
(v) Reported cloud cover, wind speed, and ambient temperature should be consistent with that reported by the nearest weather station; the Administrator may request justification of any discrepancy.
(4) Profile determination procedure.
(i) Drain the fuel tank(s) and fill with test fuel to the “tank fuel volume” defined in § 86.082-2. The test fuel should meet the specifications of § 86.113, except that fuel with a lower volatility may be used, subject to Administrator approval. Manufacturers using a lower volatility fuel must generate a vapor temperature profile for demonstrating compliance with the limit on fuel tank pressure during the running loss test (see § 86.134-96).
(ii) The vehicle shall be moved to the location where the data is to be collected. It may be driven a maximum distance of 5 miles and may also be transported by other means. The vehicle shall be stabilized by one of the following methods:
(A) The vehicle shall be parked for a minimum of 12 hours in an open area on a surface that is representative of the test road, without any artificial heating or cooling of the fuel. The orientation of the front of the vehicle during parking (e.g., N, SW, etc.) shall be documented.
(B) The vehicle may be soaked in a temperature-controlled environment to stabilize fuel temperatures. Before starting the drive, the vehicle shall be stabilized with fuel temperatures 95 ±3 °F for at least one hour. The fuel temperature may not exceed 98 °F at any time before the beginning of the driving schedule, during which only whole-vehicle heating and cooling may be used to control fuel temperatures. If a manufacturer uses the provisions of paragraph (d)(7)(v) of this section to establish a lower initial fuel temperature for the running loss test, the fuel in the test vehicle may not be stabilized at a temperature higher than the newly established initial fuel temperature.
(iii) Once the ambient conditions specified in paragraph (d)(3) of this section are met and the vehicle has been stabilized according to paragraph (d)(4)(ii) of this section, the vehicle's engine may be started. The vehicle's air conditioning system (if so equipped) shall be set to the “normal” air conditioning mode and adjusted to the minimum discharge air temperature and high fan speed. Vehicles equipped with automatic temperature controlled air conditioning systems shall be set to operate in “automatic” temperature and fan modes with the system set at 72 °F.
(iv) The vehicle may be operated at minimum throttle for a period up to 60 seconds prior to the start of the driving schedule, as necessary to move from the parking location onto the road surface. The driver's aid shall be started and the vehicle operated over the driving cycle specified in § 86.134-96(b) with the transmission operated in the same manner as specified in § 86.128-79. The data recording system shall provide a record of the required parameters over the entire period of driving.
(5) Records required. In addition to the vehicle data recording, the following parameters shall be documented for the determination of the fuel temperature profile:
(i) Date and time of vehicle fueling;
(ii) Odometer reading at vehicle fueling;
(iii) Date and time vehicle was parked, parking location and orientation;
(iv) Odometer reading at parking;
(v) Date and time engine was started;
(vi) Time of initiation of first UDDS;
(vii) Time of completion of the driving cycle;
(viii) Ambient temperatures throughout the period of driving (Tamb);
(ix) Wind speed throughout the period of driving;
(x) Track surface temperatures throughout the period of driving cycle (Tsur);
(xi) Percent cloud cover during the period of driving; and
(xii) Ambient temperature, wind speed, and percent cloud cover reported by the nearest weather station for the time corresponding most closely to the period of driving.
(6) Fuel tank pressure. Tank pressure shall not exceed 10 inches of water at any time during the temperature profile determination unless a pressurized system is used and the manufacturer demonstrates that vapor would not be vented to the atmosphere upon fuel cap removal.
(7) Calculation of temperature profiles.
(i) The traces from the driving schedule shall be verified to meet the speed tolerance requirements of § 86.115. The following conditions shall be verified:
(A) Tamb, i≥Tamb, o−2 °F.
Where,
(1) i = instantaneous measurement throughout the drive; and
(2) o = initial measurement at the start of the specified driving schedule.
(B) Tamb, o≥95 °F.
(C) Tsur, i−Tamb, i≥30 °F.
(D) Wmax≤15 mph.
(ii) Failure to comply with any of these requirements shall result in invalidation of the data and require that the procedure be repeated, beginning with the fuel drain at paragraph (d)(4)(i) of this section.
(iii) If all these requirements are met, the following calculations shall be performed to determine a profile for liquid fuel temperatures and, if applicable, for vapor temperatures:
Ti, profile = Ti-To.
Where:
(A) Ti,profile = the series of temperatures that comprise the relative temperature profile.
(B) Ti = the series of observed liquid fuel or vapor temperatures during the drive.
(C) To = the liquid fuel or vapor temperature observed at the start of the specified driving schedule.
(iv) The relative temperature profile consists of the set of temperatures at each 1-minute interval. If temperatures are sampled more frequently than once per minute, the temperature data points may represent a rolling average of temperatures sampled for up to one-minute intervals. If multiple valid test runs are conducted for any model, then all the collected data shall be used to calculate a composite profile, based on the average temperatures at each point. The absolute temperature profile is determined by adding 95 °F (35 °C) to each point of the relative profile. Other methodologies for developing corrected liquid fuel and vapor space temperature profiles may be used if demonstrated to yield equivalent results and approved in advance by the Administrator.
(v) Manufacturers may use a lower initial fuel temperature for the running loss test, if approved in advance by the Administrator. To demonstrate the need for such an adjustment, manufacturers would be expected to determine the maximum fuel temperature experienced by a vehicle during an extended park or after driving one UDDS cycle when exposed to the ambient conditions described in paragraph (d)(3) of this section. To use this provision, manufacturers would have to show maximum fuel temperatures no greater than 92 °F.
[56 FR 25775, June 5, 1991, as amended at 58 FR 16033, Mar. 24, 1993; 59 FR 39649, Aug. 3, 1994; 60 FR 43891, Aug. 23, 1995; 65 FR 59956, Oct. 6, 2000]