Part 3280 - Manufactured Home Construction and Safety Standards  


Subpart A - General
§ 3280.1 - Scope.
§ 3280.2 - Definitions.
§ 3280.3 - Manufactured home procedural and enforcement regulations, and consumer manual requirements.
§ 3280.4 - Incorporation by reference.
§ 3280.5 - Data plate.
§ 3280.6 - Serial number.
§ 3280.7 - Excluded structures.
§ 3280.8 - Waivers.
§ 3280.9 - Interpretative bulletins.
§ 3280.10 - Use of alternative construction.
§ 3280.11 - Certification label.
Subpart B - Planning Considerations
§ 3280.101 - Scope.
§ 3280.102 - Definitions.
§ 3280.103 - Light and ventilation.
§ 3280.104 - Ceiling heights.
§ 3280.105 - Exit facilities; exterior doors.
§ 3280.106 - Exit facilities; egress windows and devices.
§ 3280.107 - Interior privacy.
§ 3280.108 - Interior passage.
§ 3280.109 - Room requirements.
§ 3280.110 - Minimum room dimensions.
§ 3280.111 - Toilet compartments.
§ 3280.112 - Hallways.
§ 3280.113 - Glass and glazed openings.
§ 3280.114 - xxx
Subpart C - Fire Safety
§ 3280.201 - Scope.
§ 3280.202 - Definitions.
§ 3280.203 - Flame spread limitations and fire protection requirements.
§ 3280.204 - Kitchen cabinet protection.
§ 3280.205 - Carpeting.
§ 3280.206 - Fireblocking.
§ 3280.207 - Requirements for thermal insulating materials.
§ 3280.208 - Requirements for foam plastic thermal insulating materials.
§ 3280.209 - Smoke alarm requirements.
§ 3280.210 - Fire testing.
§ 3280.211 - xxx
§ 3280.212 - xxx
§ 3280.213 - xxx
Subpart D - Body and Frame Construction Requirements
§ 3280.301 - Scope.
§ 3280.302 - Definitions.
§ 3280.303 - General requirements.
§ 3280.304 - Materials.
§ 3280.305 - Structural design requirements.
§ 3280.306 - Windstorm protection.
§ 3280.307 - Resistance to elements and use.
§ 3280.308 - Formaldehyde emission controls for composite wood products
§ 3280.309 - Health Notice on formaldehyde emissions.
Subpart E - Testing
§ 3280.401 - Structural load tests.
§ 3280.402 - Test procedures for roof trusses.
§ 3280.403 - Requirements for windows, sliding glass doors, and skylights.
§ 3280.404 - Standard for egress windows and devices for use in manufactured homes.
§ 3280.405 - Standard for swinging exterior passage doors for use in manufactured homes.
§ 3280.406 - Air chamber test methods for certification and continuing qualification of formaldehyde emission levels.
§ 3280.407 - xxx
Subpart F - Thermal Protection
§ 3280.501 - Scope.
§ 3280.502 - Definitions.
§ 3280.503 - Materials.
§ 3280.504 - Condensation control and installation of vapor retarders.
§ 3280.505 - Air infiltration.
§ 3280.506 - Heat loss/heat gain.
§ 3280.507 - Comfort heat gain.
§ 3280.508 - Heat loss, heat gain and cooling load calculations.
§ 3280.509 - Criteria in absence of specific data.
§ 3280.510 - Heat loss certificate.
§ 3280.511 - Comfort cooling certificate and information.
Subpart G - Plumbing Systems
§ 3280.601 - Scope.
§ 3280.602 - Definitions.
§ 3280.603 - General requirements.
§ 3280.604 - Materials.
§ 3280.605 - Joints and connections.
§ 3280.606 - Traps and cleanouts.
§ 3280.607 - Plumbing fixtures.
§ 3280.608 - Hangers and supports.
§ 3280.609 - Water distribution systems.
§ 3280.610 - Drainage systems.
§ 3280.611 - Vents and venting.
§ 3280.612 - Tests and inspection.
Subpart H - Heating, Cooling and Fuel Burning Systems
§ 3280.701 - Scope.
§ 3280.702 - Definitions.
§ 3280.703 - Minimum standards.
§ 3280.704 - [Reserved]
§ 3280.705 - Gas piping systems.
§ 3280.706 - Oil piping systems.
§ 3280.707 - Heat producing appliances.
§ 3280.708 - Exhaust duct system and provisions for the future installation of a clothes dryer.
§ 3280.709 - Installation of appliances.
§ 3280.710 - Venting, ventilation and combustion air.
§ 3280.711 - Instructions.
§ 3280.712 - Marking.
§ 3280.713 - Accessibility.
§ 3280.714 - Appliances, cooling.
§ 3280.715 - Circulating air systems.
Subpart I - Electrical Systems
§ 3280.801 - Scope.
§ 3280.802 - Definitions.
§ 3280.803 - Power supply.
§ 3280.804 - Disconnecting means and branch-circuit protective equipment.
§ 3280.805 - Branch circuits required.
§ 3280.806 - Receptacle outlets.
§ 3280.807 - Fixtures and appliances.
§ 3280.808 - Wiring methods and materials.
§ 3280.809 - Grounding.
§ 3280.810 - Electrical testing.
§ 3280.811 - Calculations.
§ 3280.812 - Wiring of expandable units and dual units.
§ 3280.813 - Outdoor outlets, fixtures, air-conditioning equipment, etc.
§ 3280.814 - Painting of wiring.
§ 3280.815 - Polarization.
§ 3280.816 - Examination of equipment for safety.
Subpart J - Transportation
§ 3280.901 - Scope.
§ 3280.902 - Definitions.
§ 3280.903 - General requirements for designing the structure to withstand transportation shock and vibration.
§ 3280.904 - Specific requirements for designing the transportation system.
Subpart K - Attached Manufactured Homes and Special Construction Considerations
§ 3280.1001 - Scope.
§ 3280.1002 - Definitions.
§ 3280.1003 - Attached manufactured home unit separation.
§ 3280.1004 - Exterior walls.
§ 3280.1005 - Electrical service.
§ 3280.1006 - Water service.