§ 84.104 - Gas tightness test; minimum requirements.
Latest version.
-
§ 84.104 Gas tightness test; minimum requirements.
(a) Each apparatus will be tested for tightness by persons wearing it in an atmosphere of 1,000 p.p.m. isoamyl acetate.
(b) Six persons will each wear the apparatus in the test concentrations specified in paragraph (a) of this section for 2 minutes and none shall detect the odor or taste of the test vapor.