§ 154.709 - Cargo boil-off as fuel: Gas detection equipment.


Latest version.
  • § 154.709 Cargo boil-off as fuel: Gas detection equipment.

    (a) The continuous gas detection system required under § 154.706(a)(2) and (b) must:

    (1) Meet § 154.1350(c), (d), and (j) through (s); and

    (2) Have a device that:

    (i) Activates an audible and visual alarm at the machinery control station and in the wheelhouse if the methane concentration reaches 1.5 percent by volume; and

    (ii) Closes the master gas fuel valve required under § 154.708(c) before the methane concentration reaches 3 percent by volume.

    (b) The number and arrangement of gas sampling points must be specially approved by the Commandant (CG-OES).

    [CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]