Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 10 - Energy |
Chapter II - Department of Energy |
SubChapter D - Energy Conservation |
Part 429 - Certification, Compliance, and Enforcement for Consumer Products and Commercial and Industrial Equipment |
Subpart C - Enforcement |
Appendix B to Subpart C of Part 429 - Sampling Plan for Enforcement Testing of Covered Equipment and Certain Low-Volume Covered Products
-
Appendix B to Subpart C of Part 429 - Sampling Plan for Enforcement Testing of Covered Equipment and Certain Low-Volume Covered Products
The Department will determine compliance as follows:
(a) The first sample size (n1) must be four or more units, except as provided by § 429.57(e)(1)(ii).
(b) Compute the mean of the measured energy performance (x1) for all tests as follows:
where xi is the measured energy efficiency or consumption from test i, and n1 is the total number of tests.
(c) Compute the standard deviation (s1) of the measured energy performance from the n1 tests as follows:
(d) Compute the standard error (sx1) of the measured energy performance from the n1 tests as follows:
(e)
(f)
(1) Compare the sample mean to the control limit.
(i) The basic model is in compliance and testing is at an end if:
(A) For an energy or water efficiency standard, the sample mean is equal to or greater than the lower control limit, or
(B) For an energy or water consumption standard, the sample mean is equal to or less than the upper control limit.