Appendix to Subpart F of Part 655 - —Alternate Method of Determining the Color of Retroreflective Sign Materials and Pavement Marking Materials


Latest version.
  • Appendix to Subpart F of Part 655 - Alternate Method of Determining the Color of Retroreflective Sign Materials and Pavement Marking Materials

    1. Although the FHWA Color Tolerance Charts depreciate the use of spectrophotometers or accurate tristimulus colorimeters for measuring the daytime color of retroreflective materials, recent testing has determined that 0/45 or 45/0 spectroradiometers and tristimulus colorimeters have proved that the measurements can be considered reliable and may be used.

    2. The daytime color of non-fluorescent retroreflective materials may be measured in accordance with ASTM Test Method E1349, “Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Bidirectional Geometry” or ASTM Test Method E 1347 (Replaces E97), “Standard Test Method for Color and Color-Difference Measurement by Tristimulus (Filter) Colorimetry.” The latter test method specified bidirectional geometry for the measurement of retroreflective materials. The geometric conditions to be used in both test methods are 0/45 or 45/0 circumferential illumination or viewing. Uniplanar geometry is not recommended for material types IV or higher (designated microprismatic). The CIE standard illuminant used in computing the colorimetric coordinates shall be D65 and the 2 Degree Standard CIE observer shall be used.

    3. For fluorescent retroreflective materials ASTM E991 may be used to determine the chromaticity provided that the D65 illumination meets the requirements of E 991. This practice, however, allows only the total luminous factor to be measured. The fluorescent luminous factor must be determined using bispectral fluorescent colorimetry. Commercial instruments are available which allow such determination. Some testing laboratories are also equipped to perform these measurements.

    4. For nighttime measurements CIE Standard Illuminant A shall be used in computing the colorimetric coordinates and the 2 Degree Standard CIE Observer shall be used.

    5. Average performance sheeting is identified as Types I and II sheeting and high performance sheeting is identified as Type III. Super-high intensity sheeting is identified as Types V, VI, and VII in ASTM D 4956.

    6. The following nine tables depict the 1931 CIE Chromaticity Diagram x and y coordinates for the corner points defining the recommended color boxes in the diagram and the daytime luminance factors for those colors. Lines drawn between these corner points specify the limits of the chromaticity allowed in the 1931 Chromaticity Diagram. Color coordinates of samples that lie within these lines are acceptable. For blue and green colors the spectrum locus is the defining limit between the corner points located on the spectrum locus:

    Table 1 to Appendix to Part 655, Subpart F - Daytime Color Specification Limits for Retroreflective Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65.

    Color Chromaticity Coordinates
    1 2 3 4
    x y x y y x x y
    White 0.303 0.300 0.368 0.366 0.340 0.393 0.274 0.329
    Red 0.648 0.351 0.735 0.265 0.629 0.281 0.565 0.346
    Orange 0.558 0.352 0.636 0.364 0.570 0.429 0.506 0.404
    Brown 0.430 0.340 0.430 0.390 0.518 0.434 0.570 0.382
    Yellow 0.498 0.412 0.557 0.442 0.479 0.520 0.438 0.472
    Green 0.026 0.399 0.166 0.364 0.286 0.446 0.207 0.771
    Blue 0.078 0.171 0.150 0.220 0.210 0.160 0.137 0.038
    Light Blue 0.180 0.260 0.240 0.300 0.270 0.260 0.230 0.200
    Purple 0.302 0.064 0.310 0.210 0.380 0.255 0.468 0.140

    Table 1a to Appendix to Part 655, Subpart F - Daytime Luminance Factors (%) for Retroreflective Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65.

    Color Daytime Luminance Factor (Y %) by ASTM Type
    Types I, II, III and VI Types IV, VII, and VIII Type V
    Minimum Maximum Minimum Maximum Minimum Maximum
    White 27 40 15
    Red 2.5 12 3.0 15 2.5 11
    Orange 14 30 12 30 7.0 25
    Brown 4.0 9.0 1.0 6.0 1.0 9.0
    Yellow 15 45 24 45 12 30
    Green 3.0 9.0 3.0 12 2.5 11
    Blue 1.0 10 1.0 10 1.0 10
    Light Blue 12 40 18 40 8.0 25
    Purple 2.0 10 2.0 10 2.0 10

    Table 2 to Appendix to Part 655, Subpart F - Nighttime Color Specification Limits for Retroreflective Material With CIE 2° Standard Observer and Observation Angle of 0.33°, Entrance Angle of + 5° and CIE Standard Illuminant A.

    Color Chromaticity Coordinates
    1 2 3 4
    x y x y x y x y
    White 0.475 0.452 0.360 0.415 0.392 0.370 0.515 0.409
    Red 0.650 0.348 0.620 0.348 0.712 0.2550 0.735 0.265
    Orange 0.595 0.405 0.565 0.405 0.613 0.355 0.643 0.355
    Brown 0.595 0.405 0.540 0.405 0.570 0.365 0.643 0.355
    Yellow 0.513 0.487 0.500 0.4700 0.545 0.425 0.572 0.425
    Green 0.007 0.570 0.200 0.500 0.322 0.590 0.193 0.782
    Blue 0.033 0.370 0.180 0.370 0.230 0.240 0.091 0.133
    Purple 0.355 0.088 0.385 0.288 0.500 0.350 0.635 0.221
    Light Blue Chromaticity coordinates are yet to be determined.

    Table 3 to Appendix to Part 655, Subpart F - Daytime Color Specification Limits for Fluorescent Retroreflective Material with CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65.

    Color Chromaticity Coordinates
    1 2 3 4
    x y x y x y x y
    Fluorescent Orange 0.583 0.416 0.535 0.400 0.595 0.351 0.645 0.355
    Fluorescent Yellow 0.479 0.520 0.446 0.483 0.512 0.421 0.557 0.442
    Fluorescent Yellow-Green 0.387 0.610 0.369 .546 .428 .496 0.460 0.540
    Fluorescent Green 0.210 0.770 0.232 0.656 0.320 0.590 0.320 0.675
    Fluorescent Pink 0.450 0.270 0.590 0.350 0.644 0.290 0.536 0.230
    Fluorescent Red 0.666 0.334 0.613 0.333 0.671 0.275 9.735 0.265

    Table 3a to Appendix to Part 655, Subpart F - Daytime Luminance Factors (%) for Fluorescent Retroreflective Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65.

    Color Luminance Factor Limits (Y)
    Min Max YF*
    Fluorescent Orange 25 None 15
    Fluorescent Yellow 45 None 20
    Fluorescent Yellow-Green 60 None 20
    Fluorescent Green 20 30 12
    Fluorescent Pink 25 None 15
    Fluorescent Red 20 30 15

    Table 4 to Appendix to Part 655, Subpart F - Nighttime Color Specification Limits for Fluorescent Retroreflective Material With CIE 2° Standard Observer and Observation Angle of 0.33°, Entrance Angle of + 5° and CIE Standard Illuminant A.

    Color Chromaticity Coordinates
    1 2 3 4
    x y x y x y x y
    Fluorescent Orange 0.625 0.375 0.589 0.376 0.636 0.330 0.669 0.331
    Fluorescent Yellow 0.554 0.445 0.526 0.437 0.569 0.394 0.610 0.390
    Fluorescent Yellow-Green 0.480 0.520 0.473 0.490 0.523 0.440 0.550 0.449
    Fluorescent Green 0.007 0.570 0.200 0.500 0.322 0.590 0.193 0.782
    Fluorescent Red 0.680 0.320 0.645 0.320 0.712 0.253 0.735 0.265

    Table 5 to Appendix to Part 655, Subpart F - Daytime Color Specification Limits for Retroreflective Pavement Marking Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65.

    Color Chromaticity Coordinates
    1 2 3 4
    x y x y x y x y
    White 0.355 0.355 0.305 0.305 0.285 0.325 0.335 0.375
    Yellow 0.560 0.440 0.490 0.510 0.420 0.440 0.460 0.400
    Red 0.480 0.300 0.690 0.315 0.620 0.380 0.480 0.360
    Blue 0.105 0.100 0.220 0.180 0.200 0.260 0.060 0.220
    Purple 0.300 0.064 0.309 0.260 0.362 0.295 0.475 0.144

    Table 5a to Appendix to Part 655, Subpart F - Daytime Luminance Factors (%) for Retroreflective Pavement Marking Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65.

    Color Luminance Factor (Y%)
    Minimum Maximum
    White 35
    Yellow 25
    Red 6 15
    Blue 5 14
    Purple 5 15

    Table 6 to Appendix to Part 655, Subpart F - Nightime Color Specification Limits for Retroreflective Pavement Marking Material With CIE 2° Standard Observer, Observation Angle of 1.05°, Entrance Angle of + 88.76° and CIE Standard Illuminant A.

    Color Chromaticity Coordinates
    1 2 3 4
    x y x y x y x y
    White 0.480 0.410 0.430 0.380 0.405 0.405 0.455 0.435
    Yellow 0.575 0.425 0.508 0.415 0.473 0.453 0.510 0.490
    Purple 0.338 0.080 0.425 0.365 0.470 0.385 0.635 0.221

    [67 FR 49572, July 31, 2002, as amended at 67 FR 70163, Nov. 21, 2002; 68 FR 65582, 65583, Nov. 20, 2003; 74 FR 66862, 66863, Dec. 16, 2009]