Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 24 - Housing and Urban Development |
Subtitle B - Regulations Relating to Housing and Urban Development |
Chapter XX - Office of Assistant Secretary for Housing - Federal Housing Commissioner, Department of Housing and Urban Development |
Part 3285 - Model Manufactured Home Installation Standards |
Subpart E - Anchorage Against Wind |
§ 3285.405 - Severe wind zones.
Latest version.
-
§ 3285.405 Severe wind zones.
When any part of a home is installed within 1,500 feet of a coastline in Wind Zones II or III, the manufactured home must be designed for the increased requirements, as specified on the home's data plate (refer to § 3280.5(f) of this chapter) in accordance with acceptable engineering practice. Where site or other conditions prohibit the use of the manufacturer's instructions, a registered professional engineer or registered architect, in accordance with acceptable engineering practice, must design anchorage for the special wind conditions.