Table 3 of Subpart AAAA to Part 60 - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)  


Latest version.
  • For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate pollutant concentration levels Use the following methods in appendix A of this part to measure oxygen (or carbon dioxide)
    1. Nitrogen Oxides (Class I units only)aMethod 7, 7A, 7B, 7C, 7D, or 7EMethod 3 or 3A.
    2. Sulfur DioxideMethod 6 or 6CMethod 3 or 3A.
    3. Carbon MonoxideMethod 10, 10A, or 10BMethod 3 or 3A.

    aClass I units mean small municipal waste combustion units subject to this subpart that are located at municipal waste combustion plants with an aggregate plant combustion capacity more than 250 tons per day of municipal solid waste. See §60.1465 for definitions.