Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 40 - Protection of Environment |
Chapter I - Environmental Protection Agency |
SubChapter C - Air Programs |
Part 60 - Standards of Performance for New Stationary Sources |
Subpart BBBB - Emission Guidelines and Compliance Times for Small Municipal Waste Combustion Units Constructed on or Before August 30, 1999 |
Table 5 to Subpart BBBB of Part 60 - Model Rule - Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units
Latest version.
-
Table 5 to Subpart BBBB of Part 60 - Model Rule - Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units
For the following municipal waste combustion units You must meet the following carbon monoxide limitsa Using the following averaging timesb 1. Fluidized bed 100 parts per million by dry volume 4-hour. 2. Fluidized bed, mixed fuel, (wood/refuse-derived fuel) 200 parts per million by dry volume 24-hourc. 3. Mass burn rotary refractory 100 parts per million by dry volume 4-hour. 4. Mass burn rotary waterwall 250 parts per million by dry volume 24-hour. 5. Mass burn waterwall and refractory 100 parts per million by dry volume 4-hour. 6. Mixed fuel-fired, (pulverized coal/refuse-derived fuel) 150 parts per million by dry volume 4-hour. 7. Modular starved-air and excess air 50 parts per million by dry volume 4-hour. 8. Spreader stoker, mixed fuel-fired (coal/refuse-derived fuel) 200 parts per million by dry volume 24-hour daily. 9. Stoker, refuse-derived fuel 200 parts per million by dry volume 24-hour daily.