Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 40 - Protection of Environment |
Chapter I - Environmental Protection Agency |
SubChapter C - Air Programs |
Part 63 - National Emission Standards for Hazardous Air Pollutants for Source Categories |
Subpart DDDDD - National Emission Standards for Hazardous Air Pollutants for Major Sources: Industrial, Commercial, and Institutional Boilers and Process Heaters |
Table 10 to Subpart DDDDD of Part 63 - Applicability of General Provisions to Subpart DDDDD
Latest version.
-
Table 10 to Subpart DDDDD of Part 63 - Applicability of General Provisions to Subpart DDDDD
As stated in § 63.7565, you must comply with the applicable General Provisions according to the following:
Citation Subject Applies to subpart DDDDD § 63.1 Applicability Yes. § 63.2 Definitions Yes. Additional terms defined in § 63.7575 § 63.3 Units and Abbreviations Yes. § 63.4 Prohibited Activities and Circumvention Yes. § 63.5 Preconstruction Review and Notification Requirements Yes. § 63.6(a), (b)(1)-(b)(5), (b)(7), (c) Compliance with Standards and Maintenance Requirements Yes. § 63.6(e)(1)(i) General duty to minimize emissions. No. See § 63.7500(a)(3) for the general duty requirement. § 63.6(e)(1)(ii) Requirement to correct malfunctions as soon as practicable. No. § 63.6(e)(3) Startup, shutdown, and malfunction plan requirements. No. § 63.6(f)(1) Startup, shutdown, and malfunction exemptions for compliance with non-opacity emission standards. No. § 63.6(f)(2) and (3) Compliance with non-opacity emission standards. Yes. § 63.6(g) Use of alternative standards Yes, except § 63.7555(d)(13) specifies the procedure for application and approval of an alternative timeframe with the PM controls requirement in the startup work practice (2). § 63.6(h)(1) Startup, shutdown, and malfunction exemptions to opacity standards. No. See § 63.7500(a). § 63.6(h)(2) to (h)(9) Determining compliance with opacity emission standards No. Subpart DDDDD specifies opacity as an operating limit not an emission standard. § 63.6(i) Extension of compliance Yes. Note: Facilities may also request extensions of compliance for the installation of combined heat and power, waste heat recovery, or gas pipeline or fuel feeding infrastructure as a means of complying with this subpart. § 63.6(j) Presidential exemption. Yes. § 63.7(a), (b), (c), and (d) Performance Testing Requirements Yes. § 63.7(e)(1) Conditions for conducting performance tests No. Subpart DDDDD specifies conditions for conducting performance tests at § 63.7520(a) to (c). § 63.7(e)(2)-(e)(9), (f), (g), and (h) Performance Testing Requirements Yes. § 63.8(a) and (b) Applicability and Conduct of Monitoring Yes. § 63.8(c)(1) Operation and maintenance of CMS Yes. § 63.8(c)(1)(i) General duty to minimize emissions and CMS operation No. See § 63.7500(a)(3). § 63.8(c)(1)(ii) Operation and maintenance of CMS Yes. § 63.8(c)(1)(iii) Startup, shutdown, and malfunction plans for CMS No. § 63.8(c)(2) to (c)(9) Operation and maintenance of CMS Yes. § 63.8(d)(1) and (2) Monitoring Requirements, Quality Control Program Yes. § 63.8(d)(3) Written procedures for CMS Yes, except for the last sentence, which refers to a startup, shutdown, and malfunction plan. Startup, shutdown, and malfunction plans are not required. § 63.8(e) Performance evaluation of a CMS Yes. § 63.8(f) Use of an alternative monitoring method. Yes. § 63.8(g) Reduction of monitoring data Yes. § 63.9 Notification Requirements Yes. § 63.10(a), (b)(1) Recordkeeping and Reporting Requirements Yes. § 63.10(b)(2)(i) Recordkeeping of occurrence and duration of startups or shutdowns Yes. § 63.10(b)(2)(ii) Recordkeeping of malfunctions No. See § 63.7555(d)(7) for recordkeeping of occurrence and duration and § 63.7555(d)(8) for actions taken during malfunctions. § 63.10(b)(2)(iii) Maintenance records Yes. § 63.10(b)(2)(iv) and (v) Actions taken to minimize emissions during startup, shutdown, or malfunction No. § 63.10(b)(2)(vi) Recordkeeping for CMS malfunctions Yes. § 63.10(b)(2)(vii) to (xiv) Other CMS requirements Yes. § 63.10(b)(3) Recordkeeping requirements for applicability determinations No. § 63.10(c)(1) to (9) Recordkeeping for sources with CMS Yes. § 63.10(c)(10) and (11) Recording nature and cause of malfunctions, and corrective actions No. See § 63.7555(d)(7) for recordkeeping of occurrence and duration and § 63.7555(d)(8) for actions taken during malfunctions. § 63.10(c)(12) and (13) Recordkeeping for sources with CMS Yes. § 63.10(c)(15) Use of startup, shutdown, and malfunction plan No. § 63.10(d)(1) and (2) General reporting requirements Yes. § 63.10(d)(3) Reporting opacity or visible emission observation results No. § 63.10(d)(4) Progress reports under an extension of compliance Yes. § 63.10(d)(5) Startup, shutdown, and malfunction reports No. See § 63.7550(c)(11) for malfunction reporting requirements. § 63.10(e) Additional reporting requirements for sources with CMS Yes. § 63.10(f) Waiver of recordkeeping or reporting requirements Yes. § 63.11 Control Device Requirements No. § 63.12 State Authority and Delegation Yes. § 63.13-63.16 Addresses, Incorporation by Reference, Availability of Information, Performance Track Provisions Yes. § 63.1(a)(5),(a)(7)-(a)(9), (b)(2), (c)(3)-(4), (d), 63.6(b)(6), (c)(3), (c)(4), (d), (e)(2), (e)(3)(ii), (h)(3), (h)(5)(iv), 63.8(a)(3), 63.9(b)(3), (h)(4), 63.10(c)(2)-(4), (c)(9). Reserved No. [76 FR 15664, Mar. 21, 2011, as amended at 78 FR 7205, Jan. 31, 2013; 80 FR 72830, Nov. 20, 2015]