Table 4 to Subpart TTTTT of Part 63 - Continuous Compliance With Emission Limits  


Latest version.
  • Table 4 to Subpart TTTTT of Part 63 - Continuous Compliance With Emission Limits

    As required in § 63.9923, you must demonstrate continuous compliance with the emission limits according to the following table:

    For . . . You must demonstrate continuous compliance by . . .
    1. Each spray dryer stack a. Maintaining emissions of PM10 at or below 100 lbs/hr; and
    b. Maintaining emissions of hydrochloric acid at or below 200 lbs/hr; and
    c. Conducting subsequent performance tests at least twice during each term of your title V operating permit (at mid-term and renewal).
    2. Magnesium chloride storage bins scrubber stack a. Maintaining emissions of hydrochloric acid at or below 47.5 lbs/hr and 0.35 gr/dscf; and
    b. Maintaining emissions of PM10 at or below 2.7 lbs/hr and 0.016 gr/dscf; and
    c. Conducting subsequent performance tests at least twice during each term of your title V operating permit (at mid-term and renewal).
    3. Each melt/reactor system stack a. Maintaining emissions of PM10 at or below 13.1 lbs/hr; and
    b. Maintaining emissions of hydrochloric acid at or below 7.2 lbs/hr; and
    c. Maintaining emissions of chlorine at or below 100 lbs/hr; and
    d. Maintaining emissions of dioxins/furans at or below 36 ng TEQ/dscm corrected to 7% oxygen.
    e. Conducting subsequent performance test at least twice during each term of your title V operating permit (at mid-term and renewal).
    4. Each launder off-gas system stack a. Maintaining emissions of particulate matter at or below 37.5 lbs/hr; and
    b. Maintaining emissions of hydrochloric acid at or below 46.0 lbs/hr; and
    c. Maintaining emissions of chlorine at or below 26.0 lbs/hr; and
    d. Conducting subsequent performance tests at least twice during each term of your title V operating permit (at mid-term and renewal).