Table 1 to Subpart UUUUU of Part 63 - —Emission Limits for New or Reconstructed EGUs  


Latest version.
  • Table 1 to Subpart UUUUU of Part 63—Emission Limits for New or Reconstructed EGUs

    As stated in § 63.9991, you must comply with the following applicable emission limits:

    If your EGU is in this subcategory . . . For the following
    pollutants . . .
    You must meet the following emission limits and work practice standards . . . Using these requirements, as appropriate (e.g., specified sampling volume or test run duration) and limitations with the test methods in Table 5 to this Subpart . . .
    1. Coal-fired unit not low rank virgin coala. Filterable particulate matter (PM)9.0E-2 lb/MWh1 Collect a minimum catch of 6.0 milligrams or a minimum sample volume of 4 dscm per run.
    OROR
    Total non-Hg HAP metals6.0E-2 lb/GWhCollect a minimum of 4 dscm per run.
    OROR
    Individual HAP metals:Collect a minimum of 3 dscm per run.
    Antimony (Sb)8.0E-3 lb/GWh
    Arsenic (As)3.0E-3 lb/GWh
    Beryllium (Be)6.0E-4 lb/GWh
    Cadmium (Cd)4.0E-4 lb/GWh
    Chromium (Cr)7.0E-3 lb/GWh
    Cobalt (Co)2.0E-3 lb/GWh
    Lead (Pb)2.0E-2 lb/GWh
    Manganese (Mn)4.0E-3 lb/GWh
    Nickel (Ni)4.0E-2 lb/GWh
    Selenium (Se)5.0E-2 lb/GWh
    b. Hydrogen chloride (HCl)1.0E-2 lb/MWhFor Method 26A at appendix A-8 to part 60 of this chapter, collect a minimum of 3 dscm per run. For ASTM D6348-03(Reapproved 2010)2 or Method 320 at appendix A to part 63 of this chapter, sample for a minimum of 1 hour.
    OR
    Sulfur dioxide (SO2)3 1.0 lb/MWhSO2 CEMS.
    c. Mercury (Hg)3.0E-3 lb/GWhHg CEMS or sorbent trap monitoring system only.
    2. Coal-fired units low rank virgin coala. Filterable particulate matter (PM)9.0E-2 lb/MWh1 Collect a minimum catch of 6.0 milligrams or a minimum sample volume of 4 dscm per run.
    OROR
    Total non-Hg HAP metals6.0E-2 lb/GWhCollect a minimum of 4 dscm per run.
    OROR
    Individual HAP metals:Collect a minimum of 3 dscm per run.
    Antimony (Sb)8.0E-3 lb/GWh
    Arsenic (As)3.0E-3 lb/GWh
    Beryllium (Be)6.0E-4 lb/GWh
    Cadmium (Cd)4.0E-4 lb/GWh
    Chromium (Cr)7.0E-3 lb/GWh
    Cobalt (Co)2.0E-3 lb/GWh
    Lead (Pb)2.0E-2 lb/GWh
    Manganese (Mn)4.0E-3 lb/GWh
    Nickel (Ni)4.0E-2 lb/GWh
    Selenium (Se)5.0E-2 lb/GWh
    b. Hydrogen chloride (HCl)1.0E-2 lb/MWhFor Method 26A, collect a minimum of 3 dscm per run For ASTM D6348-03(Reapproved 2010)2 or Method 320, sample for a minimum of 1 hour.
    OR
    Sulfur dioxide (SO2)3 1.0 lb/MWhSO2 CEMS.
    c. Mercury (Hg)Before July 8, 2024: 4.0E-2 lb/GWh; On or after July 8, 2024: 1.3E-2 lb/GWhHg CEMS or sorbent trap monitoring system only.
    3. IGCC unita. Filterable particulate matter (PM)7.0E-2 lb/MWh4 9.0E-2 lb/MWh5 Collect a minimum of 1 catch of 3.0 milligrams or a minimum sample volume of 2 dscm per run.
    OROR
    Total non-Hg HAP metals4.0E-1 lb/GWhCollect a minimum of 1 dscm per run.
    OROR
    Individual HAP metals:Collect a minimum of 2 dscm per run.
    Antimony (Sb)2.0E-2 lb/GWh
    Arsenic (As)2.0E-2 lb/GWh
    Beryllium (Be)1.0E-3 lb/GWh
    Cadmium (Cd)2.0E-3 lb/GWh
    Chromium (Cr)4.0E-2 lb/GWh
    Cobalt (Co)4.0E-3 lb/GWh
    Lead (Pb)9.0E-3 lb/GWh
    Manganese (Mn)2.0E-2 lb/GWh
    Nickel (Ni)7.0E-2 lb/GWh
    Selenium (Se)3.0E-1 lb/GWh
    b. Hydrogen chloride (HCl)2.0E-3 lb/MWhFor Method 26A, collect a minimum of 1 dscm per run; for Method 26 at appendix A-8 to part 60 of this chapter, collect a minimum of 120 liters per run.
    For ASTM D6348-03(Reapproved 2010)2 or Method 320, sample for a minimum of 1 hour.
    OR
    Sulfur dioxide (SO2)3 4.0E-1 lb/MWhSO2 CEMS.
    c. Mercury (Hg)3.0E-3 lb/GWhHg CEMS or sorbent trap monitoring system only.
    4. Liquid oil-fired unit—continental (excluding limited-use liquid oil-fired subcategory units)a. Filterable particulate matter (PM)3.0E-1 lb/MWh1 Collect a minimum of 1 dscm per run.
    OROR
    Total HAP metals2.0E-4 lb/MWhCollect a minimum of 2 dscm per run.
    OROR
    Individual HAP metals:Collect a minimum of 2 dscm per run.
    Antimony (Sb)1.0E-2 lb/GWh
    Arsenic (As)3.0E-3 lb/GWh
    Beryllium (Be)5.0E-4 lb/GWh
    Cadmium (Cd)2.0E-4 lb/GWh
    Chromium (Cr)2.0E-2 lb/GWh
    Cobalt (Co)3.0E-2 lb/GWh
    Lead (Pb)8.0E-3 lb/GWh
    Manganese (Mn)2.0E-2 lb/GWh
    Nickel (Ni)9.0E-2 lb/GWh
    Selenium (Se)2.0E-2 lb/GWh
    Mercury (Hg)1.0E-4 lb/GWhFor Method 30B at appendix A-8 to part 60 of this chapter sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be < 12 the standard.
    b. Hydrogen chloride (HCl)4.0E-4 lb/MWhFor Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03(Reapproved 2010)2 or Method 320, sample for a minimum of 1 hour.
    c. Hydrogen fluoride (HF)4.0E-4 lb/MWhFor Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03 (Reapproved 2010)2 or Method 320, sample for a minimum of 1 hour.
    5. Liquid oil-fired unit—non-continental (excluding limited-use liquid oil-fired subcategory units)a. Filterable particulate matter (PM)2.0E-1 lb/MWh1 Collect a minimum of 1 dscm per run.
    OROR
    Total HAP metals7.0E-3 lb/MWhCollect a minimum of 1 dscm per run.
    OROR
    Individual HAP metals:Collect a minimum of 3 dscm per run.
    Antimony (Sb)8.0E-3 lb/GWh
    Arsenic (As)6.0E-2 lb/GWh
    Beryllium (Be)2.0E-3 lb/GWh
    Cadmium (Cd)2.0E-3 lb/GWh
    Chromium (Cr)2.0E-2 lb/GWh
    Cobalt (Co)3.0E-1 lb/GWh
    Lead (Pb)3.0E-2 lb/GWh
    Manganese (Mn)1.0E-1 lb/GWh
    Nickel (Ni)4.1E0 lb/GWh
    Selenium (Se)2.0E-2 lb/GWh
    Mercury (Hg)4.0E-4 lb/GWhFor Method 30B sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be < 12 the standard.
    b. Hydrogen chloride (HCl)2.0E-3 lb/MWhFor Method 26A, collect a minimum of 1 dscm per run; for Method 26, collect a minimum of 120 liters per run. For ASTM D6348-03 (Reapproved 2010)2 or Method 320, sample for a minimum of 1 hour.
    c. Hydrogen fluoride (HF)5.0E-4 lb/MWhFor Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03 (Reapproved 2010)2 or Method 320, sample for a minimum of 1 hour.
    6. Solid oil-derived fuel-fired unita. Filterable particulate matter (PM)3.0E-2 lb/MWh1 Collect a minimum of 1 dscm per run.
    OROR
    Total non-Hg HAP metals6.0E-1 lb/GWhCollect a minimum of 1 dscm per run.
    OROR
    Individual HAP metals:Collect a minimum of 3 dscm per run.
    Antimony (Sb)8.0E-3 lb/GWh
    Arsenic (As)3.0E-3 lb/GWh
    Beryllium (Be)6.0E-4 lb/GWh
    Cadmium (Cd)7.0E-4 lb/GWh
    Chromium (Cr)6.0E-3 lb/GWh
    Cobalt (Co)2.0E-3 lb/GWh
    Lead (Pb)2.0E-2 lb/GWh
    Manganese (Mn)7.0E-3 lb/GWh
    Nickel (Ni)4.0E-2 lb/GWh
    Selenium (Se)6.0E-3 lb/GWh
    b. Hydrogen chloride (HCl)4.0E-4 lb/MWhFor Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03 (Reapproved 2010)2 or Method 320, sample for a minimum of 1 hour.
    OR
    Sulfur dioxide (SO2)3 1.0 lb/MWhSO2 CEMS.
    c. Mercury (Hg)2.0E-3 lb/GWhHg CEMS or Sorbent trap monitoring system only.

    [81 FR 20190, Apr. 6, 2016, as amended at 89 FR 38569, May 7, 2024]