§ 108.597 - Line-throwing appliance.


Latest version.
  • § 108.597 Line-throwing appliance.

    (a) General. Each unit in international service must have a line-throwing appliance that is approved under approval series 160.040. Each unit not in international service must carry a line-throwing appliance approved under either approval series 160.040 or 160.031.

    (b) Stowage. The line-throwing appliance and its equipment must be readily accessible for use.

    (c) Additional equipment. Each unit must carry the following equipment for the line-throwing appliance:

    (1) The equipment on the list provided by the manufacturer with the approved appliance; and

    (2) An auxiliary line that -

    (i) Has a breaking strength of at least 40 kiloNewtons (9,000 pounds-force);

    (ii) Is, if synthetic, a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light; and

    (iii) Is -

    (A) At least 450 meters (1,500 feet) long, if the line-throwing appliance is approved under approval series 160.040; or

    (B) At least 150 meters (500 feet) long, if the line-throwing appliance is approved under approval series 160.031.