Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 46 - Shipping |
Chapter I - Coast Guard, Department of Homeland Security |
SubChapter M - Towing Vessels |
Part 142 - Fire Protection |
Subpart B - General Requirements for Towing Vessels |
§ 142.230 - Portable fire extinguishers and semi-portable fire-extinguishing systems.
-
§ 142.230 Hand-portable Portable fire extinguishers and semi-portable fire-extinguishing systems.
(a) Hand-portable fire extinguishers and semi-portable fire-extinguishing systems are classified by a combination letter and Roman numeral. The letter indicates the type of fire which the unit could be expected to extinguish, and the Roman numeral indicates the relative size of the unit.
(b) For the purpose of this subchapter, all required hand-portable fire extinguishers and semi-portable fire-extinguishing systems must include Type B classification, suitable for extinguishing fires involving flammable liquids, grease, etc.
(c) The number designations for size run from “I” for the smallest to “V” for the largest. Sizes I and II are hand-portable fire extinguishers; sizes III, IV, and V are semi-portable fire-extinguishing systems, which must be fitted with hose and nozzle or other practical means to cover all portions of the space involved. Examples of the sizes for some of the typical hand-portable fire extinguishers and semi-portable fire-extinguishing systems appear in Table 142.230(c) of this section.
Table 142.230(c) - Portable and Semi-Portable Extinguishers
Classification Foam, liters (gallons) Carbon dioxide, kilograms (pounds) Dry chemical, kilograms (pounds)B-I 4.75 (1.25) 2 (4) 1 (2) B-II 9.5 (2.5) 7 (15) 4.5 (10) B-III 45 (12) 16 (35) 9 (20) B-IV 75 (20) 23 (50) 13.5 (30) B-V 125 (33) 45 (100) 23 (50) (d)
(1)hand-Towing vessels of 65 feet or less in length must carry at least the minimum number of
Tableportable fire extinguishers set forth in
d)(1) of this sectiond(1)table 142.230(
B-I Hand--
B-I hand-10-B:C Portable Fire Extinguishers
Length, feet Minimum number of B-II hand-10-B:C portable fire extinguishers
required1No fixed fire-extinguishing system in
machinery spaceFixed fire-
extinguishing
system in
machinery spaceUnder 262 1 0 26 and over, but under 40 2 1 40 and over, but not over 65 3 2 B-I hand-2(
atb) Towing vessels of more than 65 feet in length must carry
hand--
(1) At least the minimum number of
Tableportable fire extinguishers set forth in
dtable 142.230(
of this section.b); and
(2)
Table 142.230(d)(2) - B-II Hand-Portable Fire Extinguishers
Gross tonnage - Minimum number of B-II hand-portable fire extinguishers Over Not over 50 1 50 100 2 100 500 3 500 1,000 6 1,000 8 (i) In addition to the hand-portable extinguishers required by paragraph (d)(2) of this section, one Type B-II hand-portable fire extinguisher must be-IIOne 40-B portable fire extinguisher fitted in the engine room for each 1,000 brake horsepower of the main engines or fraction thereof. A towing vessel is not required to carry more than six additional 40-B
irrespectiveportable fire extinguishers in the engine room for this purpose,
ii) [Reserved] (eregardless of horsepower.
Table 142.230(
b) - 40-B:C Portable Fire Extinguishers
Gross tonnage - Minimum number
of 40-B:C
portable fire
extinguishersOver Not over 50 1 50 100 2 100 500 3 500 1,000 6 1,000 8 size III, IV, or V(c) The frame or support of any
semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions.
(d) Extinguishers with larger numerical ratings or multiple letter designations may be used if the extinguishers meet the minimum requirements of this section.
[USCG-2017-1060, 83 FR 8180, Feb. 26, 2018]