§ 142.230 - Portable fire extinguishers and semi-portable fire-extinguishing systems.  


Latest version.
  • § 142.230 Hand-portable Portable fire extinguishers and semi-portable fire-extinguishing systems.

    (a) Hand-portable fire extinguishers and semi-portable fire-extinguishing systems are classified by a combination letter and Roman numeral. The letter indicates the type of fire which the unit could be expected to extinguish, and the Roman numeral indicates the relative size of the unit.

    (b) For the purpose of this subchapter, all required hand-portable fire extinguishers and semi-portable fire-extinguishing systems must include Type B classification, suitable for extinguishing fires involving flammable liquids, grease, etc.

    (c) The number designations for size run from “I” for the smallest to “V” for the largest. Sizes I and II are hand-portable fire extinguishers; sizes III, IV, and V are semi-portable fire-extinguishing systems, which must be fitted with hose and nozzle or other practical means to cover all portions of the space involved. Examples of the sizes for some of the typical hand-portable fire extinguishers and semi-portable fire-extinguishing systems appear in Table 142.230(c) of this section.

    Table 142.230(c) - Portable and Semi-Portable Extinguishers

    Classification Foam, liters (gallons) Carbon dioxide, kilograms (pounds) Dry chemical, kilograms (pounds) B-I4.75 (1.25)2 (4)1 (2) B-II9.5 (2.5)7 (15)4.5 (10) B-III45 (12)16 (35)9 (20) B-IV75 (20)23 (50)13.5 (30) B-V125 (33)45 (100)23 (50)

    (d)

    (1)

    Towing vessels of 65 feet or less in length must carry at least the minimum number of

    hand-

    portable fire extinguishers set forth in

    Table

    table 142.230(

    d)(1) of this section

    a).

    Table 142.230(

    d(1)

    -

    B-I Hand-

    10-B:C Portable Fire Extinguishers

    Length, feet Minimum number of
    B-I hand-
    10-B:C portable fire extinguishers
    required1
    No fixed fire-extinguishing system in
    machinery space
    Fixed fire-
    extinguishing
    system in
    machinery space
    Under 262 10
    26 and over, but under 4021
    40 and over, but not over 6532
    B-II hand-
    B-I hand-

    (

    2

    b) Towing vessels of more than 65 feet in length must carry

    at

    -

    (1) At least the minimum number of

    hand-

    portable fire extinguishers set forth in

    Table

    table 142.230(

    d

    b); and

    (2)

    of this section.

    Table 142.230(d)(2) - B-II Hand-Portable Fire Extinguishers

    Gross tonnage - Minimum number of B-II hand-portable fire extinguishers Over Not over 501 501002 1005003 5001,0006 1,0008(i) In addition to the hand-portable extinguishers required by paragraph (d)(2) of this section, one Type B-II hand-portable fire extinguisher must be

    One 40-B portable fire extinguisher fitted in the engine room for each 1,000 brake horsepower of the main engines or fraction thereof. A towing vessel is not required to carry more than six additional 40-B

    -II

    portable fire extinguishers in the engine room for this purpose,

    irrespective

    regardless of horsepower.

    Table 142.230(

    ii) [Reserved] (e

    b) - 40-B:C Portable Fire Extinguishers

    Gross tonnage - Minimum number
    of 40-B:C
    portable fire
    extinguishers
    Over Not over
    501
    501002
    1005003
    5001,0006
    1,0008

    (c) The frame or support of any

    size III, IV, or V

    semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions.

    (d) Extinguishers with larger numerical ratings or multiple letter designations may be used if the extinguishers meet the minimum requirements of this section.

    [USCG-2017-1060, 83 FR 8180, Feb. 26, 2018]