§ 154.310 - Cargo piping systems.  


Latest version.
  • § 154.310 Cargo piping systems.

    Cargo liquid or vapor piping must:

    (a) Be separated from other piping systems, except where an interconnection to inert gas or purge piping is required by § 154.901(a);

    (b) Not enter or pass through any accommodation, service, or control space;

    (c) Except as allowed under § 154.703, not enter or pass through a machinery space other than a cargo pump or compressor room;

    (d) Be in the cargo area except:

    (1) As allowed under § 154.703;

    (2) Bow and stern loading piping; and

    (3) Emergency jettisoning piping.

    (e) Be above the weather deck except:

    (1) As allowed under § 154.703;

    (2) Pipes in a trunk traversing void spaces above a cargo containment system; and

    (3) Pipes for draining, venting, or purging interbarrier and hold spaces;

    (f) Connect into the cargo containment system above the weather deck except:

    (1) Pipes in a trunk traversing void spaces above a cargo containment system; and

    (2) Pipes for draining, venting, or purging interbarrier and hold spaces.

    (g) Be inboard of the transverse cargo tank location required by § 154.235, except for athwartship shore connection manifolds not subject to internal pressure at sea.