§ 154.506 - Mechanical expansion joint: Limits in a piping system.  


Latest version.
  • § 154.506 Mechanical expansion joint: Limits in a piping system.

    Mechanical expansion joints in a piping system outside of a cargo tank:

    (a) May be installed only if offsets, loops or bends cannot be installed due to limited space or piping arrangement;

    (b) Must be a bellows type; and

    (c) Must not have insulation or a cover unless necessary to prevent damage.